Errors in the function block

No.

Message text

Cause

Remedy

501

INTERNAL ERROR

Internal exceptional error

Contact KUKA Deutschland GmbH. (>>> KUKA Service)

502

INVALID BUFFER_MODE

BufferMode 0: DIRECT is not permissible for this function block.

Program the correct mode:

  • 1: ABORTING
  • 2: BUFFERED

(>>> BufferMode)

503

INVALID MXA VERSION

The software versions of the mxA interface and PLC library are not compatible.

Install compatible software versions on the robot controller and PLC.

(>>> Initializing the mxA interface)

504

INVALID OVERRIDE

Invalid override value in the function block KRC_SetOverride

Program a valid value (parameter Override):

  • 0 … 100%

505

MAX GROUP REF IDX REACHED

The axis group index specified in the function block KRC_ReadAxisGroup is already assigned.

Only instance the KRC_ReadAxisGroup function block once in a program.

506

INVALID GROUPREFIDX

The axis group index specified in the function block is invalid.

Specify a valid index for the axis group (parameter AxisGroupIdx).

507

INVALID FB ORDER

The order in which the function blocks are called is invalid.

Program the function blocks in the correct order.

508

CONNECTION NOT INITIALIZED

No statements can be transferred, as the mxA interface has not been initialized.

Initialize the mxA interface.

(>>> Initializing the mxA interface)

509

510

NO CONNECTION TO KRC

TIMEOUT HEARTBEAT FROM KRC

Connection to robot controller interrupted

Restore connection, then acknowledge error.

The robot controller is switched off.

Reboot the robot controller.

Submit interpreter deselected or stopped

Restart submit interpreter.

Bus error or I/O configuration faulty

Check I/O configuration.

Connecting cable defective or not connected correctly.

Exchange connecting cable or connect it correctly.

Maximum cycle time of the submit interpreter is too short (only for message no. 510)

Increase the value for MaxSubmitCycle in the KRC_Diag function block.

A function was called by the input ExecuteCmd before the interface was initialized.

Wait for the output KRC_Initialize.Done before calling a function with ExecuteCmd.

To reset the error, set the input ExecuteCmd to the value FALSE.

511

TIMEOUT CMD INTERFACE BLOCKED

The ExecuteCmd input was reset before the Busy signal was set.

Acknowledge the message and in the future do not reset the input ExecuteCmd until the Done, Error or Aborted signal has been set.

512

INVALID CHECKSUM KRC -> PLC

The checksum for data transmission from the robot controller to the PLC is invalid.

Error on booting:

  • PROFINET configuration in iiQWorks.Sim or CODESYS incorrect

Check configuration in iiQWorks.Sim and CODESYS and configure PROFINET correctly.

Error during operation:

  • Bit error during data transmission

Contact KUKA Deutschland GmbH. (>>> KUKA Service)

513

INVALID POSITION INDEX

An invalid number for the position to be taught has been transferred in the KRC_TouchUP function block.

Program a valid value (parameter Index):

  • 1 … 100

514

POS_ACT INVALID

The current position cannot be taught, as the position data are invalid (no BCO).

Establish BCO with a RESET in the KRC_AutomaticExternal function block.

517

INVALID COMMAND SIZE

Internal exceptional error

Contact KUKA Deutschland GmbH. (>>> KUKA Service)

518

KRC STOPMESS ACTIVE

Group error which prevents motion enable

Check how the error was triggered and eliminate the error.

  • Analyze the messages in the message window of the iiQKA.OS2 user interface.
  • Read the current error state of the robot controller with the KRC_ReadKRCError function block.

519

INVALID ABSOLUTE VELOCITY

An invalid value has been programmed for the parameter AbsoluteVelocity in a KRC_Move function block.

Contact KUKA Deutschland GmbH. (>>> KUKA Service)

520

VELOCITY CONFLICT

Multiple values have been programmed for the speed in a KRC_Move function block.

Contact KUKA Deutschland GmbH. (>>> KUKA Service)

521

INVALID PARAMETER COUNT

An invalid value has been programmed for the parameter ParameterCount in a KRC_TechFunction function block.

Contact KUKA Deutschland GmbH. (>>> KUKA Service)

522

INVALID PARAMETER USAGE

The parameter ParameterCount has been incorrectly configured in the KRC_TechFunction function block.

Contact KUKA Deutschland GmbH. (>>> KUKA Service)

523

INVALID OPERATION MODE

The robot is in the incorrect operating mode.

Select Automatic External mode.

524

USER_SAF SIGNAL NOT ACTIVE

The operator safety is violated.

Close the safeguard and acknowledge the closed state.

525

ALARM_STOP SIGNAL NOT ACTIVE

The safety configuration is incorrect and an EMERGENCY STOP has been triggered.

Check and modify the safety configuration of the system (robot controller and PLC).

No connection to the EMERGENCY STOP of the system

Check the EMERGENCY STOP of the system and reestablish the connection.

The inputs and outputs of the Automatic External interface are incorrectly configured.

  1. In the main menu, select System Settings > Automatic External.
  2. Select the Inputs or Outputs subgroup.
  3. Check and modify the configuration of the inputs and outputs.

526

APPL_RUN SIGNAL ACTIVE

RESET cannot be carried out because a robot program is being executed.

  1. Wait until the robot program has been executed.
  2. Execute the statement again.

527

TIMEOUT MESSAGE CONFIRM

The message cannot be acknowledged by the PLC.

Acknowledge the message on the robot controller.

528

TIMEOUT MXA MESSAGE CONFIRM

An error cannot be acknowledged in the KRC_AutoStart function block.

Contact KUKA Deutschland GmbH. (>>> KUKA Service)

529

TIMEOUT SWITCHING DRIVES ON

Internal exceptional error

Contact KUKA Deutschland GmbH. (>>> KUKA Service)

530

TIMEOUT PROGRAM SELECTION

Internal exceptional error

531

TIMEOUT PROGRAM START

Internal exceptional error

532

MOVE_ENABLE SIGNAL NOT ACTIVE

The robot does not have a motion enable

Issue motion enable with the parameter MOVE_ENABLE.

533

INVALID AXIS_VALUES

Not all axis angles required for execution are defined in the KRC_Forward function block.

Define the missing axis angles in the KRC_Forward function block.

534

INVALID $BASE

Internal exceptional error

Contact KUKA Deutschland GmbH. (>>> KUKA Service)

535

INVALID $TOOL

Internal exceptional error

536

INVALID SOFTEND

Error in the function block KRC_Forward:

The specified axis angles lie outside the software limit switches.

Enter axis angles that lie within the software limit switches (parameter Axis_Values).

or: Modify the software limit switches.

537

ERR MATH TRAFO

Error in the function block KRC_Forward:

The robot cannot reach the specified axis angles.

Enter axis angles that the robot can reach (parameter Axis_Values).

538

INVALID AXIS_VALUES

Error in the function block KRC_Inverse:

  • The Cartesian robot position has not been fully specified.
  • The axis-specific values at the start point of the motion have not been fully specified.
  • Fully specify the Cartesian robot position (parameter Position).
  • Fully specify the axis-specific values at the start point of the motion (parameter Start_Axis).

539

INVALID $BASE

Internal exceptional error

Contact KUKA Deutschland GmbH. (>>> KUKA Service)

540

INVALID $TOOL

Internal exceptional error

541

INVALID SOFTEND

Error in the function block KRC_Inverse:

The axis-specific values at the start point of the motion lie outside the software limit switches.

Enter values that lie within the software limit switches (parameter Start_Axis).

Or: Modify the software limit switches.

542

ERR MATH TRAFO

Error in the function block KRC_Inverse:

The robot cannot reach the specified axis-specific values at the start point of the motion.

Enter values that the robot can reach (parameter Start_Axis).

543

INVALID EXECUTE

During a linked motion capable of being approximated, the Execute input was reset before the ComAcpt signal was set by the function block.

Acknowledge the message and in the future do not reset the input “Execute” until the ComAcpt signal has been set.

544

INVALID DEV_VEL_CP

Initialization of the mxA interface on the robot controller has not yet been completed or has an error.

Check whether the output Done is active in the KRC_Initialize function block.

547

INVALID TURN

Error in the function block KRC_Inverse:

With the specified Turn, the axis-specific values at the specified position are located outside the software limit switches.

Enter values that lie within the software limit switches (parameter Position).

Or: Modify the software limit switches.

548

InvJogCmd

Error in the function block KRC_Jog or KRC_JogAdvanced:

Two jog keys have been pressed simultaneously.

To jog, press only one jog key at a time.

550

Internal error: initializing LDD failed.

Error in the function block KRC_LDDconfig or KRC_LDDstart:

Initalization of load data determination has failed.

Execute the function block again.

If the error persists, contact KUKA Deutschland GmbH. (>>> KUKA Service)

551

Applying manual mass settings for LDD failed.

Error in the function block KRC_LDDconfig:

The manual setting of the mass for load data determination has failed.

  1. Set the payload (parameter Mass) to a value appropriate for your use case.
  2. Execute the function block again.

552

Setting start position for LDD failed.

Error in the function block KRC_LDDconfig:

The current axis position is not a valid start position for load data determination.

  1. Move the robot to a valid start position, e.g. (0, -90, 90, 0, 0, 0).
  2. Execute the function block again.

Further information on the start position for load data determination can be found in the documentation for iiQKA.LoadDataDetermination.

Error in the function block KRC_LDDstart:

The axis position used when calling the function block KRC_LDDconfig is not a valid start position for load data determination.

  1. Move the robot to a valid start position (e.g. (0, -90, 90, 0, 0, 0)).
  2. Execute the function block KRC_LDDconfig.
  3. Execute the function block KRC_LDDstart again.

Further information on the start position for load data determination can be found in the documentation for iiQKA.LoadDataDetermination.

553

Setting supplementary load for LDD failed.

Error in the function block KRC_LDDconfig:

The current supplementary load setting is not valid.

Pass a valid supplementary load configuration and execute the function block again.

Further information on the supplementary load configuration can be found in the documentation for iiQKA.LoadDataDetermination.

Error in the function block KRC_LDDstart:

The configuration used when calling the function block KRC_LDDconfig is not a valid supplementary load setting.

  1. Pass a valid supplementary load configuration.
  2. Execute the function block KRC_LDDconfig.
  3. Execute the function block KRC_LDDstart again.

Further information on the supplementary load configuration can be found in the documentation for iiQKA.LoadDataDetermination.

554

Internal error: Setting acceleration scaling factor for LDD failed.

Error in the function block KRC_LDDconfig or KRC_LDDstart:

Setting the acceleration factor for load data determination has failed.

Execute the function block again.

If the error persists, contact KUKA Deutschland GmbH. (>>> KUKA Service)

555

Internal error: Finalizing configuration of LDD failed.

Error in the function block KRC_LDDconfig or KRC_LDDstart:

Finalizing the configuration for load data determination has failed.

Execute the function block again.

If the error persists, contact KUKA Deutschland GmbH. (>>> KUKA Service)

556

Invalid supplementary load option selected for LDD (*LoadA3Settings* parameter).

Error in the function block KRC_LDDconfig:

An invalid value has been set for the parameter LoadA3Settings.

  1. Set the parameter LoadA3Settings to the value 0, 1, 2 or 3.
  2. Execute the function block again.

557

Override must be 100 to execute LDD run.

Error in the function block KRC_LDDstart:

Function block has been executed with a program override < 100%.

  1. Set the program override to 100% (function block KRC_SetOverride).
  2. Execute the KRC_LDDstart function block again.

558

Internal error: Setting run mode for LDD failed.

Error in the function block KRC_LDDtestRun or KRC_LDDstart:

Setting the internal run mode for load data determination has failed.

Execute the function block again.

If the error persists, contact KUKA Deutschland GmbH. (>>> KUKA Service)

559

Internal error: Getting number of identification runs of LDD failed.

Error in the function block KRC_LDDtestRun or KRC_LDDstart:

Retrieving the number of identification runs for load data determination has failed.

Execute the function block again.

If the error persists, contact KUKA Deutschland GmbH. (>>> KUKA Service)

560

Internal error: Getting starting position for next movement during LDD failed.

Error in the function block KRC_LDDtestRun or KRC_LDDstart:

Retrieving the start position for the next movement during load data determination has failed.

Execute the function block again.

If the error persists, contact KUKA Deutschland GmbH. (>>> KUKA Service)

561

Internal error: Calculation step during LDD failed.

Error in the function block KRC_LDDtestRun or KRC_LDDstart:

A calculation step during load data determination has failed.

Execute the function block again.

If the error persists, contact KUKA Deutschland GmbH. (>>> KUKA Service)

562

Internal error: Getting load identified via LDD failed.

Error in the function block KRC_LDDstart or KRC_LDDwriteLoad:

Retrieving the identified load has failed.

Execute the function block again.

If the error persists, contact KUKA Deutschland GmbH. (>>> KUKA Service)

563

Override must be smaller than or equal to 10 to execute LDD test run.

Error in the function block KRC_LDDtestRun:

Function block has been executed with a program override ≥ 10%.

  1. Set the program override to ≤ 10% (function block KRC_SetOverride).
  2. Execute the KRC_LDDtestRun function block again.

590

InvMoveType

Error in the function block KRC_Jog or KRC_JogAdvanced:

An invalid value has been programmed for the parameter MoveType.

Program a valid value for the parameter MoveType.

(>>> Jogging to an end position)

(>>> Jogging to the end position (advanced))