Selecting the tool, base and interpolation mode
Description
The function block KRC_SetCoordSys can be used to set the tool, base and interpolation mode without having to execute a motion at the same time. This function is required, for example, to read the current position in different coordinate systems.
![]() | Further information about the tool and base in the robot system is provided in the operating and programming instructions for the system software. |
Inputs
Parameter | Type | Description |
|---|---|---|
AxisGroupIdx | INT | Index of axis group
|
ExecuteCmd | BOOL | The statement is executed in the case of a rising edge of the signal. |
CoordinateSystem | COORDSYS | Coordinate system to which the specified values refer (>>> COORDSYS) |
BufferMode | INT | Mode in which the statement is executed
(>>> BufferMode) |
Outputs
Parameter | Type | Description |
|---|---|---|
Busy | BOOL | TRUE = statement is currently being transferred or has already been transferred |
Done | BOOL | TRUE = statement has been executed |
Aborted | BOOL | TRUE = statement has been aborted |
Error | BOOL | TRUE = error in function block |
ErrorID | DINT | Error number |
OrderID | DINT | OrderID number |