Stopping the tracking of a scene

Description

The function block KRC_ConvTrackingOff is used to stop tracking a scene (workpiece) on the conveyor. The time of the stop depends on the setting of the parameter ExecuteType.

Stopping the tracking of a scene 1:

Inputs

Parameter

Type

Description

AxisGroupIdx

INT

Index of axis group

  • 1 … 5

ExecuteCmd

BOOL

Starts execution in the case of a rising edge of the signal.

ExecuteType

INT

Defines how the tracking is to be stopped

  • 1 (AdvanceRunStop): The tracking is stopped immediately with an advance run stop
  • 2 (TrigStartPoint): The tracking is stopped when the next motion is started

BufferMode

INT

Mode in which the statement is executed

  • 1: ABORTING
  • 2: BUFFERED

(>>> BufferMode)

Outputs

Parameter

Type

Description

Busy

BOOL

TRUE = statement is currently being transferred or has already been transferred

Active

BOOL

TRUE = statement is currently being executed

Done

BOOL

TRUE = statement has been executed

Aborted

BOOL

TRUE = statement has been aborted

Error

BOOL

TRUE = error in function block

ErrorID

DINT

Error number

OrderID

DINT

OrderID number