Tracking a scene on the conveyor

Description

The function block KRC_ConvTrackingOn enables the robot to track a scene (workpiece) on the conveyor. The different input parameters of the function block can be used to define the following:

Tracking a scene on the conveyor 1:

Inputs

Parameter

Type

Description

AxisGroupIdx

INT

Index of axis group

  • 1 … 5

ExecuteCmd

BOOL

Starts execution in the case of a rising edge of the signal.

ConveyorIndex

INT

Index of conveyor

  • 1 … 5

SceneSelection

INT

Scene to be tracked

  • 1 (NextSyncable): Next syncable scene
  • 2 (Current): Last scene tracked
  • 3 (Next): Next scene (starting from the last scene tracked)
  • 4 (Previous): Previous scene (starting from the last scene tracked)
  • 5 (Latest): Latest scene
  • 6 (StepScenes): Moves on by the specified number of scenes (starting from the last scene tracked)
  • 7 (AbsoluteScene): Scene with an absolute number

SceneStepOffset

INT

Only used if value of SceneSelection is set to StepScenes.

Number of scenes to be skipped between two consecutive scenes

SceneAbsoluteId

INT

Only used if value of SceneSelection is set to AbsoluteScene.

Absolute index of the scene to be tracked

MoveToStandby

BOOL

TRUE = If the desired scene is not yet present, the robot moves to standby position

StartOfWorkAreaOffset

REAL

Offset added to the start of the work area

EndOfSyncAreaOffset

REAL

Offset added to the end of the synchronization area

AlarmDistanceOffset

REAL

Offset added to the alarm distance

EndOfWorkAreaOffset

REAL

Offset added to the end of the work area

RetractionMotionVelocity

REAL

Velocity of the retraction motion

RetractionMotionAcceleration

REAL

Acceleration of the retraction motion

RetractionMotionVectorX

REAL

Relative retraction motion in X direction

RetractionMotionVectorY

REAL

Relative retraction motion in Y direction

RetractionMotionVectorZ

REAL

Relative retraction motion in Z direction

BufferMode

INT

Mode in which the statement is executed

  • 1: ABORTING
  • 2: BUFFERED

(>>> BufferMode)

Outputs

Parameter

Type

Description

Busy

BOOL

TRUE = statement is currently being transferred or has already been transferred

Active

BOOL

TRUE = statement is currently being executed

Done

BOOL

TRUE = statement has been executed

Aborted

BOOL

TRUE = statement has been aborted

Error

BOOL

TRUE = error in function block

ErrorID

DINT

Error number

OrderID

DINT

OrderID number