Initialize conveyors
Description
The function block KRC_ConvInit is used to initialize and activate all conveyors.
Inputs
Parameter | Type | Description |
|---|---|---|
AxisGroupIdx | INT | Index of axis group
|
ExecuteCmd | BOOL | Starts execution in the case of a rising edge of the signal. |
BufferMode | INT | Mode in which the statement is executed
(>>> BufferMode) |
Outputs
Parameter | Type | Description |
|---|---|---|
Busy | BOOL | TRUE = statement is currently being transferred or has already been transferred |
Active | BOOL | TRUE = statement is currently being executed |
Done | BOOL | TRUE = statement has been executed |
Aborted | BOOL | TRUE = statement has been aborted |
Error | BOOL | TRUE = error in function block |
ErrorID | DINT | Error number |
OrderID | DINT | OrderID number |