Calculating the Cartesian robot position from the axis angles

Description

The function block KRC_Forward uses specified axis angles to calculate the Cartesian robot position.

Calculating the Cartesian robot position from the axis angles 1:

Inputs

Parameter

Type

Description

AxisGroupIdx

INT

Index of axis group

  • 1 … 5

ExecuteCmd

BOOL

Starts/buffers the statement at a rising edge of the signal.

Axis_Values

E6AXIS

Axis-specific values that are to be converted to Cartesian coordinates

(>>> E6AXIS)

The data structure E6AXIS contains the angle values or translation values for all axes of the axis group in this position.

Check­SoftEnd

BOOL

Checks whether the specified axis angles lie within the software limit switches. If not, an error number is displayed.

BufferMode

INT

Mode in which the statement is executed

  • 1: ABORTING
  • 2: BUFFERED

(>>> BufferMode)

Outputs

Parameter

Type

Description

Busy

BOOL

TRUE = statement is currently being transferred or has already been transferred

Done

BOOL

TRUE = statement has been executed

Position

E6POS

Cartesian robot position calculated from the specified axis angles

Aborted

BOOL

TRUE = statement has been aborted

Error

BOOL

TRUE = error in function block

ErrorID

DINT

Error number

OrderID

DINT

OrderID number