Stopping the teaching of collision detection values
Description
The function block KRC_CDStopTeaching is used to stop teaching of collision detection values. The user can decide whether to apply values automatically or retrieve the values and decide what to do with them (apply with modifications via function block KRC_CDWriteDataset).
Inputs
Parameter | Type | Description |
|---|---|---|
AxisGroupIdx | INT | Index of axis group
|
ExecuteCmd | BOOL | The statement is executed in the case of a rising edge of the signal. |
BufferMode | INT | Mode in which the statement is executed
(>>> BufferMode) |
Apply | BOOL | TRUE = learned values are applied automatically to the dataset specified in function block KRC_CDStartTeaching |
ApplyHigherOnly | BOOL | TRUE = only the data for those axes of the dataset are overwritten, for which the new learned value is higher than the original threshold |
Outputs
Parameter | Type | Description |
|---|---|---|
Busy | BOOL | TRUE = statement is currently being transferred or has already been transferred |
Active | BOOL | TRUE = statement is currently being executed |
Done | BOOL | TRUE = statement has been executed |
Aborted | BOOL | TRUE = statement has been aborted |
Error | BOOL | TRUE = error in function block |
ErrorID | DINT | Error number |
OrderID | DINT | OrderID number |
TeachingResultA1 | INT | Learned collision detection value for robot axis A1 … A6 If the parameter Apply was set to TRUE, the new values of the dataset are returned. If the parameter Apply was set to FALSE, the learned values are still returned, but the dataset is not updated. |
TeachingResultA2 | INT | |
TeachingResultA3 | INT | |
TeachingResultA4 | INT | |
TeachingResultA5 | INT | |
TeachingResultA6 | INT | |
TeachingResultE1 | INT | Learned collision detection value for external axis E1 … E6 If the parameter Apply was set to TRUE, the new values of the dataset are returned. If the parameter Apply was set to FALSE, the learned values are still returned, but the dataset is not updated. |
TeachingResultE2 | INT | |
TeachingResultE3 | INT | |
TeachingResultE4 | INT | |
TeachingResultE5 | INT | |
TeachingResultE6 | INT |