Starting the teaching of collision detection values

Description

The function block KRC_CDStartTeaching is used to start teaching of collision detection values. Maximum measured values are reset and can then be taught via executing expected motions multiple times (see system functionality collision detection). For this, execute the desired motion commands after function block KRC_CDStartTeaching finished and call function block KRC_CDStopTeaching at the end.

Starting the teaching of collision detection values 1:

Inputs

Parameter

Type

Description

AxisGroupIdx

INT

Index of axis group

  • 1 … 5

ExecuteCmd

BOOL

The statement is executed in the case of a rising edge of the signal.

BufferMode

INT

Mode in which the statement is executed

  • 1: ABORTING
  • 2: BUFFERED

(>>> BufferMode)

DatasetIndex

INT

Index of the data set which should be updated with the taught values if desired (decided when teaching is stopped)

  • 1 … 30

TeachingOffset

INT

Offset to be applied to all datasets until teaching is finished. This is to be able to teach higher values than the current threshold without being stopped by the active collision detection.

  • 0 … 500

The maximum of the original threshold value plus the teaching offset is also 500.

Outputs

Parameter

Type

Description

Busy

BOOL

TRUE = statement is currently being transferred or has already been transferred

Active

BOOL

TRUE = statement is currently being executed

Done

BOOL

TRUE = statement has been executed

Aborted

BOOL

TRUE = statement has been aborted

Error

BOOL

TRUE = error in function block

ErrorID

DINT

Error number

OrderID

DINT

OrderID number