PLC Library: Tc2_PlcInterpolation

The Tc2_PlcInterpolation library offers an alternative to the application of G-Code (DIN 66025). This library can be used to execute interpolated movement commands directly from the PLC, without using G-Code.

PLC Library: Tc2_PlcInterpolation 1:

Alternative for Pick-and-Place Applications

TF5420 TwinCAT 3 Motion Pick-and-Place executes multi-dimensional motions. It was specially developed for the requirements of pick-and-place applications and is an alternative to the Tc2_PlcInterpolation library for this use case. The Tc3_McCoordinatedMotion library contains all associated function blocks.

In a first step a table of different movement commands and additional functions is written. To this end structures such as ST_NciGeoLine are transferred to the FB NciFeedTablePreparation. This appends the movement command to the table. Once the table is full or all required entries have been added, NciFeedTable is called in order to transfer the table content to the NC kernel. The data transfer directly starts the execution.

NciMaxTableEntries can be edited

From library version 3.3.16.0 (included from TC3.1.4024.11) the maximum number of table entries can be edited in the range from 10 to 32767. The default value is 100 entries.

PLC Library: Tc2_PlcInterpolation 2:

Function blocks

Function blocks that are required for grouping of axes (or for channel control (channel override) can be found in the PLC Library: Tc2_NCI.

Function Block

Description

FB_NciFeedTablePreparation

Fills a table with NCI movements in the PLC

FB_NciFeedTable

Transfers a previously written table to the NC kernel and starts the motion

Data structures

The following structures can be used as input parameters for the function block NciFeedTablePreparation:

Structures

Enum

Description

Organization

 

E_NciEntryTypeNone

No function

ST_NciGeoStart

E_NciEntryTypeGeoStart

Sets the start position for the first geometry entry

ST_NciEndOfTables

E_NciEntryTypeEndOfTables

Indicates the end of the geometry table

Movement commands

ST_NciGeoLine

E_NciEntryTypeGeoLine

Describes a straight line

ST_NciGeoCirclePlane

E_NciEntryTypeGeoCirclePlane

Describes a circle on the principal plane (center point programming)

ST_NciGeoCircleCIP

E_NciEntryTypeGeoCircleCIP

Describes a circle anywhere in the space

ST_NciGeoBezier3

E_NciEntryTypeGeoBezier3

Describes a 3rd order Bezier with control points

ST_NciGeoBezier5

E_NciEntryTypeGeoBezier5

Describes a 5rd order Bezier with control points

ST_NciDwellTime

E_NciEntryTypeDwellTime

Describes a dwell time

ST_NciSkipVirtualMovements

E_NciEntryTypeSkipVirtualMovements

Activates the skipping of virtual movements

Path parameters

ST_NciBaseFrame

E_NciEntryTypeBaseFrame

Describes a zero offset shift and rotation

ST_NciVertexSmoothing

E_NciEntryTypeVertexSmoothing

Activates blending at segment transitions

ST_NciTangentialFollowingDesc

E_NciEntryTypeTfDesc

Activates tangential following of the tool

Dynamics

ST_NciDynOvr

E_NciEntryTypeDynOvr

Modifies the dynamic override

ST_NciAxisDynamics

E_NciEntryTypeAxisDynamics

Limits the axis dynamics

ST_NciPathDynamics

E_NciEntryTypePathDynamics

Limits the path dynamics

ST_NciFeedrateIpol

E_NciEntryTypeFeedrateIpol

Sets the feed interpolation type

Parameter commands

ST_NciHParam

E_NciEntryTypeHParam

Sets an H parameter (DINT)

ST_NciSParam

E_NciEntryTypeSParam

Sets an S parameter (WORD)

ST_NciTParam

E_NciEntryTypeTParam

Sets a T parameter (WORD)

ST_NciMFuncFast

E_NciEntryTypeMFuncFast

Parameterizes a fast M-function (no handshake)

ST_NciMFuncHsk

E_NciEntryTypeMFuncHsk

Parameterizes an M-function with handshake

ST_NciMFuncResetAllFast

E_NciEntryTypeResetAllFast

Resets all fast M-functions

Requirements

Development environment

Target platform

PLC libraries to be linked

TwinCAT v3.1.0

PC or CX (x86 or x64)

Tc2_PlcInterpolation