XFC_TimeToPathPosition
The function block XFC_TimeToPathPosition calculates the time period within which an Nci group has traveled a relative path or which has elapsed since then.
The function extrapolates the time in relation to the current path position and dynamics. Precise extrapolation is only possible over a short interval, since the group dynamics may change.
The function block requires precisely one call in order to provide the result. It can therefore be used similar to a function, although as well as the time it may also return an error. This error must be analyzed in order to ensure that the calculated time duration is valid.
Inputs
VAR_INPUT
GrpId : UDINT;
PathId : UDINT;
PathPosition : LREAL;
Options : ST_NcTimeConversionOptions;
END_VARName | Type | Description |
|---|---|---|
GrpId | UDINT | Group ID of the Nci group. This clearly identifies the requested Nci group in the system. |
PathId | UDINT | Unique ID that continually increases over the path course and belongs to the relative path. |
PathPosition | LREAL | Relative path |
Options | Data structure with options for the extrapolation of the relative path. |
Outputs
VAR_OUTPUT
Duration : DINT;
TimeOfPosition : T_DCTIME32;
Error : BOOL;
ErrorID : UDINT;
END_VARName | Type | Description |
|---|---|---|
Duration | DINT | Time period in nanoseconds after which the relative path will have been travelled (>0) or which has elapsed since then (<0). Duration is a differential value from two variables of the type T_DCTIME32 |
TimeOfPosition | T_DCTIME32 | Distributed clock system time at which the relative path distance was or will have been be travelled. DcTime contains the lower 32 bits of the complete DcTime and covers a time range of +/- 2 seconds around the current time. |
Error | BOOL | Becomes TRUE if an error occurs. |
ErrorID | UDINT | If the error output is set, this parameter supplies the error number. |