T_ALY_SPInstance_Desc

T_ALY_SPInstance_Desc 1:

Syntax

Definition:

FUNCTION_BLOCK T_ALY_SPInstance_Desc EXTENDS T_ALY_JsonPayload
VAR_OUTPUT
    dtTimestamp : DATE_AND_TIME;
    bOnline     : BOOL;
    sName       : STRING;
    sVersion    : STRING;
    stInfo      : T_ALY_SPInstanceInfo;
END_VAR

Inheritance hierarchy

T_ALY_JsonPayload

    T_ALY_SPInstance_Desc

T_ALY_SPInstance_Desc 2: Outputs

Name

Type

Description

dtTimestamp

DATE_AND_TIME

Start time of the Storage Provider Service

bOnline

BOOL

Indicates whether the service is online.

sName

STRING

IoT Device name "TwinCAT Analytics Storage Provider"

sVersion

STRING

Version of the Storage Provider

stInfo

T_ALY_SPInstanceInfo

Detailed description of the Storage Provider

T_ALY_SPInstance_Desc 3: Methods

Name

Definition location

Description

Reset

 

Reset all values inside of the payload FB

Init_JsonValue

Inherited from T_ALY_JsonPayload

Initialize FB with Json object

Init_String

Inherited from T_ALY_JsonPayload

Initialize FB with Json string

GetJsonLength

Inherited from T_ALY_JsonPayload

Get Length of Json payload

GetJsonString

Inherited from T_ALY_JsonPayload

Get Json payload as String

Development environment

Target platform

PLC libraries to include

TwinCAT v3.1.4022.25

PC or CX (x64, x86, ARM)

Tc3_AnalyticsStorageProvider