TcHmiSchemaGenerator Methods

Methods

 

Name

Description

TcHmiSchemaGenerator Methods 1:

TcHmiSchemaGenerator Methods 2:

GetDefinitions(Command, IEnumerable.Definition.)

Gets the definitions from the enumerable collection of Definitions and stores them in the read value of the specified Command.

TcHmiSchemaGenerator Methods 3:

TcHmiSchemaGenerator Methods 4:

GetDefinitions.TType.(Command, IEnumerable.IDefinition.TType., TcHmiSchemaBuilder.TType.)

Gets the definitions from the enumerable collection of IDefinition.TType.s and stores them in the read value of the specified Command using the given TcHmiSchemaBuilder.TType..

TcHmiSchemaGenerator Methods 5:

TcHmiSchemaGenerator Methods 6:

GetDefinitions.TType, TInfo.(Command, IEnumerable.IExtendedDefinition.TType, TInfo.., TcHmiSchemaBuilder.TType, TInfo.)

Gets the definitions from the enumerable collection of IExtendedDefinition.TType, TInfo.s and stores them in the read value of the specified Command using the given TcHmiSchemaBuilder.TType, TInfo..

TcHmiSchemaGenerator Methods 7:

TcHmiSchemaGenerator Methods 8:

GetSchema(Command, Definition)

Gets the schema of the Definition and stores it in the read value of the specified Command.

TcHmiSchemaGenerator Methods 9:

TcHmiSchemaGenerator Methods 10:

GetSchema(Command, BuildInfo, Type, Type, Boolean)

Gets the schemas of the instances of type Type and stores them in the read value of the specified Command.

TcHmiSchemaGenerator Methods 11:

TcHmiSchemaGenerator Methods 12:

GetSchema(Command, Type, Type, Boolean, IncludeMembers, BindingFlags, ICollection.String., UInt32)

Gets the schemas of the instances of type Type and stores them in the read value of the specified Command.

TcHmiSchemaGenerator Methods 13:

TcHmiSchemaGenerator Methods 14:

GetSchema.TType.(Command, IDefinition.TType., TcHmiSchemaBuilder.TType.)

Gets the schema of the IDefinition.TType. and stores it in the read value of the specified Command using the given TcHmiSchemaBuilder.TType..

TcHmiSchemaGenerator Methods 15:

TcHmiSchemaGenerator Methods 16:

GetSchema.TType, TInfo.(Command, IExtendedDefinition.TType, TInfo., TcHmiSchemaBuilder.TType, TInfo.)

Gets the schema of the IExtendedDefinition.TType, TInfo. and stores it in the read value of the specified Command using the given TcHmiSchemaBuilder.TType, TInfo..

TcHmiSchemaGenerator Methods 17:

TcHmiSchemaGenerator Methods 18:

ListSymbols(Command, IEnumerable.Symbol.)

Lists the schemas from the enumerable collection of Symbols and stores them in the read value of the specified Command.

TcHmiSchemaGenerator Methods 19:

TcHmiSchemaGenerator Methods 20:

ListSymbols.TType.(Command, IEnumerable.ISymbol.TType., TcHmiSchemaBuilder.TType.)

Lists the schemas from the enumerable collection of ISymbol.TType.s and stores them in the read value of the specified Command using the given TcHmiSchemaBuilder.TType..

TcHmiSchemaGenerator Methods 21:

TcHmiSchemaGenerator Methods 22:

ListSymbols.TType, TInfo.(Command, IEnumerable.IExtendedSymbol.TType, TInfo.., TcHmiSchemaBuilder.TType, TInfo.)

Lists the schemas from the enumerable collection of IExtendedSymbol.TType, TInfo.s and stores them in the read value of the specified Command using the given TcHmiSchemaBuilder.TType, TInfo..

Reference

TcHmiSchemaGenerator Class

TcHmiSrv.DynamicSymbols Namespace