Analytics MQTT Acquisition

Mqtt Acquisition describes a variable for which the values are communicated via Mqtt.

Analytics MQTT Acquisition 1:

Common

Enabled

Here you can decide whether the configured channel should be recorded or not.

Name

Here you can edit the name of the acquisition.

Symbol Comment

Here the actual symbol comment is displayed, if such a comment exists.

Symbol

Area

Indicates the variable range.

ArrayLength

Indicates the length of the selected array.

DataType

Indicates the data type of the selected variable.

ForceOversampling

Indicates whether the specified variable is an oversampling variable.

SampleTime [ms]

Specifies the sampling interval for the variable.

TimeOffset[s]

This can be used for one-time manipulation of the original time stamp during recording of the data point. e.g. to compensate path differences of different target systems. The phase differences have to be determined manually by the user.

UseTaskSampleTime

Here you can specify whether the data for the selected variables are to be sampled with the TaskSampleTime or the FreeSampleTime. FreeSampleTime can be used to set the Sample Time.

VariableSize

Shows the size of the variables in bytes

Symbol MQTT

Byte Offset

Specifies the offset of a symbol.

Host

Specifies the host name of the Mqtt broker.

Name

Symbol name of the selected variable.

Time Range

Select which time range of the historical recording will be used in the new recording.

Topic

Specifies the topic under which the symbol is located.

Target

TargetSystem

Indicates the target system selected for a recording. By default this is the target system for the selected variable.

UseLocalServer

If this option is set, the Scope Server installed on the Scope View system is used for the recording. If the option is not set, the system tries to connect to the remote server of the target system.

Unit

If a unit is defined for the variable, it is displayed here. However, it cannot be edited. If a unit is to be added to the display, it must be specified with the channel.

Context menu
Further information can be found in the Acquisition context menu.