Execution of the simulation
The following chapter explains how to carry out the simulation in Autodesk® Inventor®.
When executing the simulation, it is possible to move individual axes or start a PLC project. The following is an example of how you can move individual axes.
- The CAD model is open.
- The TwinCAT project is open.
- A PLC project is open.
- The TwinCAT Runtime is initialized.
- 1. Start the TwinCAT Runtime in the add-in of Autodesk® Inventor® or activate the configuration in the TwinCAT project.
- 2. Open the axis that will be moved by double-clicking on it.
- 3. Select the Online tab.

- 4. To move manually, first set the controller enable.
- 5. Move the axis using the buttons +, ++ or the keys [F3], [F4] and the buttons -, -- or the keys [F1], [F2].
- The movement of the axis is now visible in the CAD model.

- 6. Stop the simulation by stopping the TwinCAT Runtime in the Autodesk® Inventor® add-in.