NCTOPLC_AXIS_REF
The data structure NCTOPLC_AXIS_REF is part of the AXIS_REF data structure and is automatically updated by the NC, so that updated information is available during each PLC cycle. NCTOPLC_AXIS_REF is also referred to as axis interface between NC and PLC.
TYPE NCTOPLC_AXIS_REF
STRUCT
StateDWord : NCTOPLC_AXIS_REF_STATE; (* Status double word *)
ErrorCode : DWORD; (* Axis error code *)
AxisState : DWORD; (* Axis moving status *)
AxisModeConfirmation : DWORD; (* Axis mode confirmation (feedback from NC) *)
HomingState : DWORD; (* State of axis calibration (homing) *)
CoupleState : DWORD; (* Axis coupling state *)
SvbEntries : DWORD; (* SVB entries/orders (SVB = Set preparation task) *)
SafEntries : DWORD; (* SAF entries/orders (SAF = Set execution task) *)
AxisId : DWORD; (* Axis ID *)
OpModeDWord : NCTPPLC_AXIS_REF_OPMODE; (* Current operation mode *)
ActPos : LREAL; (* Actual position (absolut value from NC) *)
ModuloActPos : LREAL; (* Actual modulo position *)
ActiveControlLoopIndex : WORD; (* Active control loop index *)
ControlLoopIndex : WORD; (* Axis control loop index (0, 1, 2, when multiple control loops are used) *)
ModuloActTurns : DINT; (* Actual modulo turns *)
ActVelo : LREAL; (* Actual velocity *)
PosDiff : LREAL; (* Position difference (lag distance) *)
SetPos : LREAL; (* Setpoint position *)
SetVelo : LREAL; (* Setpoint velocity *)
SetAcc : LREAL; (* Setpoint acceleration *)
TargetPos : LREAL; (* Estimated target position *)
ModuloSetPos : LREAL; (* Setpoint modulo position *)
ModuloSetTurns : DINT; (* Setpoint modulo turns *)
CmdNo : WORD; (* Continuous actual command number *)
CmdState : WORD; (* Command state *)
SetJerk : LREAL;
SetTorque : LREAL;
ActTorque : LREAL;
StateDWord2 : NCTOPLC_AXIS_REF_STATE2;
StateDWord3 : DWORD;
TouchProbeState : DWORD;
TouchProbeCounter : DWORD;
CamCouplingState : ARRAY [0..7] OF NCTOPLC_AXIS_REF_CAMCOUPLINGSTATE;
CamCouplingTableID : ARRAY [0..7] OF UINT;
ActTorqueDerivative : LREAL;
SetTorqueDerivative : LREAL;
AbsPhasingPos : LREAL;
TorqueOffset : LREAL
ActPosWithoutPosCorrection : LREAL;
ActAcc : LREAL;
DcTimeStamp : UDINT;
{attribute 'hide'}
_reserved2 : ARRAY [1..4] OF USINT;
UserData : LREAL;
END_TYPEVariable name | Data type | Definition range | Description |
|---|---|---|---|
StateDWord | - | State double word. | |
ErrorCode | DWORD | ≥0 | Axis error code |
AxisState | DWORD | Present state of the axis movement | |
AxisModeConfirmation | DWORD | ENUM | Axis operating mode (feedback from the NC) |
HomingState | DWORD | Reference status of the axis ("calibration status") | |
CoupleState | DWORD | Axis coupling state | |
SvbEntries | DWORD | ≥0 | SVB entries/tasks |
SafEntries | DWORD | ≥0 | SAF entries/tasks (NC interpreter, FIFO group) |
AxisId | DWORD | >0 | axis ID |
OpModeDWord. | - | Axis operation mode double word | |
ActPos | LREAL | ±∞ | Actual position (calculated absolute value) |
ModuloActPos | LREAL | ≥0 | Modulo actual position (calculated value in, for example, degrees) |
ActiveControlLoopIndex | WORD | ≥0 | Active axis control loop index |
ControlLoopIndex | WORD | ≥0 | Axis control loop index (0, 1, 2, etc. if more than one axis control loop is used) |
ModuloActTurns | DINT | ±∞ | Modulo actual rotations |
ActVelo | LREAL | ±∞ | Actual velocity (optional) |
PosDiff | LREAL | ±∞ | Lag error (position) |
SetPos | LREAL | ±∞ | Set position (calculated absolute value) |
SetVelo | LREAL | ±∞ | Set velocity |
SetAcc | LREAL | ±∞ | Set acceleration |
TargetPos | LREAL | ±∞ | Estimated target position of the axis |
ModuloSetPos | LREAL | ≥0 | Modulo set position (calculated value in, for example, degrees) |
ModuloSetTurns | DINT | ≥0 | Modulo set rotations |
CmdNo | WORD | ≥0 | Command number of the active axis job (see BufferMode) |
CmdState | WORD | ≥0 | Command status information (see BufferMode) |
SetJerk | LREAL |
| Set jerk |
SetTorque | LREAL |
| Set torque |
ActTorque | LREAL |
| Actual torque |
StateDWord2 |
| State double word 2 | |
StateDWord3 | DWORD |
| State double word 3 |
TouchProbeState | DWORD |
| TouchProbe status |
TouchProbeCounter | DWORD |
| TouchProbe counter |
CamCouplingState | ARRAY [0..7] OF NCTOPLC_AXIS_REF_CAMCOUPLINGSTATE |
| Cam coupling information for multitables (from TwinCAT 3.1.4020.0) |
CamCouplingTableId | ARRAY [0..7] OF UINT |
| Cam coupling ID for multitables (from TwinCAT 3.1.4020.0) |
ActTorqueDerivative | LREAL |
| First derivative of the actual torque |
SetTorqueDerivative | LREAL |
| First derivative of the set torque |
AbsPhasingPos | LREAL |
| Absolute phasing offset |
TorqueOffset | LREAL |
| Additive torque part |
ActPosWithoutPosCorrection | LREAL |
| Actual position without position correction |
ActAcc | LREAL |
| Actual acceleration |
DcTimeStamp | UDINT |
| Current NC timestamp |
UserData | LREAL |
| Configurable axis state parameter |
Define | Master: motion state / drive phase of the continuous master axis (servo) (AxisState) |
|---|---|
0 | Setpoint generator not active (INACTIVE) |
1 | Setpoint generator active (RUNNING) |
2 | Velocity override is zero (OVERRIDE_ZERO) |
3 | Constant velocity (PHASE_VELOCONST) |
4 | Acceleration phase (PHASE_ACCPOS) |
5 | Deceleration phase (PHASE_ACCNEG) |
Define | Master: motion state / drive phase of the discrete master axis (fast/creep) (AxisState) |
0 | Setpoint generator not active |
1 | Moving phase (rapid or slow traverse) |
2 | Switchover delay from rapid to slow traverse |
3 | Creep motion (within the creep distance) |
4 | Deceleration time (starting from the braking distance in front of the target) |
Define | Slave: motion state / drive phase of the continuous slave axis (servo) (AxisState) |
0 | Slave generator not active (INACTIVE) |
11 | Slave is in a movement pre-phase (PRE-PHASE) |
12 | Slave is synchronizing (SYNCHRONIZING) |
13 | Slave is synchronized and moves synchronously (SYNCHRON) |
Define | Calibration state of the axis (HomingState) |
|---|---|
0 | Referencing process completed (READY) |
1 | Continuous start in the direction of the referencing cam. |
2 | Wait for positive edge of the referencing cam and initiate axis stop |
3 | Wait until the axis is stopped (check whether cam is still occupied) and then endless start of the referencing cam in the direction of the sync pulse |
4 | Wait for falling edge of the referencing cam |
5 | Activate latch, wait until latch has become valid and then initiate axis stop |
6 | If axis has stopped, then set actual position (actual position = reference position + braking distance) |
See also function block description and remarks for MC_Home
Define | Coupling state of the axis (CoupleState) |
|---|---|
0 | Single axis that is neither a master nor a slave (SINGLE) |
1 | Master axis with any number of slaves (MASTER) |
2 | Slave axis that is the master of another slave (MASTERSLAVE) |
3 | Just a slave axis (SLAVE) |
Requirements
Development environment | Target system type | PLC libraries to include |
|---|---|---|
TwinCAT v3.0.0 | PC or CX (x86 or x64) | Tc2_MC2 |