Installation Sequence
Minimum Requirements:
- Beckhoff TwinCAT 2.9 Build 1025
- Beckhoff TwinCAT DriveCOM OPC Server 4.0.0.60
- Beckhoff FC310x Profibus Master with Firmware 2.56
or
Beckhoff CX1500-M310 Profibus Master with Firmware 2.57 - Siemens SimoComU 08.01.03 to access Siemens SimuDrives 611U drives
or
Siemens DriveMonitor V5.3 SP3 to access Siemens MasterVC Plus drives - Siemens 611u with firmware version 07.01.03
Installation Sequence
- Install TwinCAT
- Install TwinCAT DriveCom OPC Server
- Install SimoComU software
- Add and configure the Profibus Master in the System Manager
(See TwinCAT Profibus Master Configuration) - Add and configure the ProfiDrives in the System Manager
(See TwinCAT ProfiDrive Configuration) - Add and configure the NC-Axes in the System Manager
(See TwinCAT NC Configuration) - Activate configuration
- Configure the TwinCAT DriveCOM OPC server
(See TwinCAT DriveCOM OPC Configuration) - Configure the SimoComU software to work with TwinCAT DriveCOM OPC
(See SimoComU OPC Configuration) - Configure the ProfiDrive in SimoComU via OPC
(See SimoComU ProfiDrive Configuration)