MustConfirm
The property returns if the event has to be confirmed. This flag is true if the event was issued from the PLC function block (or other ADS device) or from a call to a Report Event Function like ITcEventLogC::ReportEvent, ITcEventC3::ReportEventEx or ITcEventLog::ReportEvent with the TcEventFlags TCEVENTFLAG_REQMUSTCON set.
HRESULT MustConfirm([out, retval] BOOL *pVal);
Parameters
pVal
[out, retval] Pointer to a BOOL value that receives the confirmation flag. It´s false if the value is 0, it´s true if the value is not equal to 0.
Return Values
S_OK
Function was successfully called
E_POINTER
pVal was no valid pointer.
Visual Basic sample code
' get the one and only event logger
Dim evtLogger As TCEVENTLOGGERLib.TcEventLog
Set evtLogger = New TCEVENTLOGGERLib.TcEventLog
' get the most recent active event
Dim evt As TcEvent
Set evt = evtLogger.GetLastEvent
' get the MustConfirm flag
Dim mustConf As Long
mustConf = evt.mustConfirm
If mustConf <> 0 Then
Debug.Print "Must Confirmed!"
Else
Debug.Print "Must Not Confirmed!"
End If
Remarks
The return value is not from the type VARIANT_BOOL the Visual Basic type BOOLEAN. In Visual Basic it occurs as a long value. We must check if it's not equal 0 if the flag is set.