ID-range 1001000-1001249

1001082 - 1001084

 

 

Description

This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer.

Reaction

Class

3

 

Solution

Class

8

Restart of NC-control necessary.

1001085

Drive reports an error.

 

Description

The SERCOS drive reports an error. Consult the documentation of the drive manufacturer for a further error diagnosis.

Reaction

Class

3

 

Solution

Class

6

 

Error type

-

 

1001086 - 1001089

 

 

Description

This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer.

Reaction

Class

3

 

Solution

Class

8

Restart of NC-control necessary.

1001090

Logical axis number not permitted.

 

Description

 

Reaction

Class

3

 

Solution

Class

6

 

Parameter

%1:

Actual value [-]

 

%2:

Limit value [-]

 

Error type

-

 

1001095

Unknown ID in List 16 or 24.

 

Description

 

Reaction

Class

-

 

Solution

Class

-

 

Error type

-

 

1001099 / 1001100

Troubleshooting classes

 

Description

This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer.

Reaction

Class

3

 

Solution

Class

8

Restart of NC-control necessary.

1001102

Block-interface for manual-mode not available.

 

Description

 

Reaction

Class

3

 

Solution

Class

7

 

Parameter

%1:

Actual value [-]

 

Error type

-

 

1001103

Troubleshooting classes

 

Description

This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer.

Reaction

Class

3

 

Solution

Class

8

Restart of NC-control necessary.

1001105

The fiber-optic transmission rate is wrong.

 

Description

 

Reaction

Class

1

 

Solution

Class

1

 

Parameter

%1:

Incorrect value [-]

 

%2:

Corrected value [-]

 

Error type

-

 

1001106

The number of SERCOS rings is wrong.

 

Description

 

Reaction

Class

1

 

Solution

Class

1

 

Parameter

%1:

Incorrect value [-]

 

%2:

Limit value [-]

 

%3:

Corrected value [-]

 

Error type

-

 

1001107

The option does not exist.

 

Description

 

Reaction

Class

1

 

Solution

Class

1

 

Parameter

%1:

Incorrect value [-]

 

%2:

Corrected value [-]

 

Error type

-

 

1001108

The time value is out of range.

 

Description

 

Reaction

Class

3

 

Solution

Class

6

 

Parameter

%1:

Incorrect value [-]

 

%2:

Limit value [-]

 

%3:

Limit value [-]

 

Error type

-

 

1001109

The optional AT- time value calculation not exist.

 

Description

 

Reaction

Class

1

 

Solution

Class

1

 

Parameter

%1:

Incorrect value [-]

 

%2:

Corrected value [-]

 

Error type

-

 

1001110

The optional digital drive driver is not available.

 

Description

 

Reaction

Class

3

 

Solution

Class

6

 

Parameter

%1:

Corrected value [-]

 

Error type

-

 

1001111

Choose interrupt number is over limit.

 

Description

 

Reaction

Class

3

 

Solution

Class

6

 

Parameter

%1:

Incorrect value [-]

 

%2:

Limit value [-]

 

Error type

-

 

1001112

Set of interrupt number impossible.

 

Description

 

Reaction

Class

3

 

Solution

Class

6

 

Parameter

%1:

Actual value [-]

 

Error type

-

 

1001113

Illegal computer address.

 

Description

 

Reaction

Class

3

 

Solution

Class

6

 

Parameter

%1:

Incorrect value [-]

 

%2:

Incorrect value [-]

 

Error type

-

 

1001114

The computer address cannot be set.

 

Description

 

Reaction

Class

3

 

Solution

Class

6

 

Parameter

%1:

Incorrect value [-]

 

Error type

-

 

1001115

Error by interpretation of CTM-DDL.

 

Description

 

Reaction

Class

3

 

Solution

Class

7

 

Parameter

%1:

Actual value [-]

 

%2:

Actual value [-]

 

Error type

-

 

1001116

CTM index out of range.

 

Description

 

Reaction

Class

3

 

Solution

Class

6

 

Parameter

%1:

Actual value [-]

 

Error type

-

 

1001117

List contains unknown elements.

 

Description

The startup list includes an unknown list element, which cannot calculated.

Reaction

Class

1

Unknown list element will be ignored.

Solution

Class

1

Remove the unknown list element or correct the wrong entry.

Error type

-

 

1001118

List contains unknown elements.

 

Description

 

Reaction

Class

1

 

Solution

Class

1

 

Error type

-

 

1001119

List contains unknown elements.

 

Description

The axis parameter list includes an unknown list element, which cannot calculated.

Reaction

Class

1

Unknown list element will be ignored.

Solution

Class

1

Remove the unknown list element or correct the wrong entry.

Error type

-

 

1001120

List contains unknown elements.

 

Description

 

Reaction

Class

1

 

Solution

Class

1

 

Error type

-

 

1001121

The same log. axis number is used several times.

 

Description

Multiple configured axes are including the same logical axis number. The logical axis number must be explicit in the control system.

Reaction

Class

3

Axis cannot be configured.

Solution

Class

6

Stop of the control startup.

Parameter

%1:

Logical axis number [-]

Multiple used logical axis number.

%2:

Actual value [-]

Axis with this index include the same logical axis number.

%3:

Actual value [-]

Axis with this index include the same logical axis number.

Error type

-

 

1001122

Axis for duplication is internally unknown.

 

Description

The given logical axis number is unknown (parameter clone_of). No duplication can be done.

Reaction

Class

3

No transfer of the axis parameter possible.

Solution

Class

7

Set the correct logical axis number.

Parameter

%1:

Logical axis number [-]

 

%2:

Incorrect value [-]

Unknown logical axis number.

Error type

6, Error message by data transfer into control device.

 

1001125

Number of channels does not match to configuration.

 

Description

For several configurations (P-STUP-00007) a set of number of channels is possible. In this case the configured number of channels does not match with the actual configuration.

Reaction

Class

1

Correction of the entry number of channels.

Solution

Class

1

Correction of the startup list.

Parameter

%1:

Expected value [-]

Expected number of channels.

%3:

Corrected value [-]

Corrected number of channels.

Error type

6, Error message by data transfer into control device.

 

1001129

Maximum number of axes exceeded; no license available.

 

Description

No license available for configured number of axes. Please contact control vendor.

Reaction

Class

3

No startup of control possible.

Solution

Class

7

Bring in missing license key or reduce number of axes.

Error type

-

 

1001130

Maximum number of channels exceeded; no license available.

 

Description

No license available for configured number of channels. Please contact control vendor.

Reaction

Class

3

No startup of control possible.

Solution

Class

7

Bring in missing license key or reduce number of channels.

Error type

-

 

1001131

File name invalid. No external HMI object list can be used.

 

Description

 

Reaction

Class

1

 

Solution

Class

1

 

Parameter

%1:

Actual value [-]

 

%2:

Incorrect value [-]

 

%3:

Corrected value [-]

 

Error type

-

 

1001132

Invalid mode. No external HMI object list can be used.

 

Description

 

Reaction

Class

1

 

Solution

Class

1

 

Parameter

%1:

Actual value [-]

 

%2:

Incorrect value [-]

 

%3:

Corrected value [-]

 

Error type

-

 

1001133

File name invalid. No external BF-Channel object list can be used.

 

Description

 

Reaction

Class

1

 

Solution

Class

1

 

Parameter

%1:

Actual value [-]

 

%2:

Incorrect value [-]

 

%3:

Corrected value [-]

 

Error type

-

 

1001134

Mode invalid. No external BF-Channel object list can be used.

 

Description

 

Reaction

Class

1

 

Solution

Class

1

 

Parameter

%1:

Actual value [-]

 

%2:

Incorrect value [-]

 

%3:

Corrected value [-]

 

Error type

-

 

1001135

List contains unknown elements.

 

Description

During interpretation of an IO devices list an unknown list element is detected.

Reaction

Class

1

 

Solution

Class

1

Remove or modify the unknown list element in the corresponding list.

Error type

-

 

1001136

No valid license for CNC export version.

 

Description

 

Reaction

Class

3

 

Solution

Class

7

 

Error type

-

 

1001137

Valid license only for CNC export version.

 

Description

 

Reaction

Class

3

 

Solution

Class

7

 

Error type

-

 

1001138

Invalid number format in list or permissible range of value exceeded.

 

Description

During interpretation of an axis parameter an invalid number format is detected or the interpreted parameter value is outside valid range.

Reaction

Class

1

Interpretation of list is continued. The parameter value is limited to the maximum or minimum permissible value or set to zero, if the number format is invalid.

Solution

Class

1

Correct the number format in the corresponding parameter list.

Error type

-

 

1001200

 

 

Description

This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer.

Reaction

Class

3

 

Solution

Class

8

Restart of NC-control necessary.