ID-range 1000000-1000249
1000000 - 1000043 |
| |||
| Description | This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer. | ||
Reaction | Class | 3 |
| |
Solution | Class | 8 | Restart of NC-control necessary. | |
1000044 | PDU-job to interprete data list fails in decoder. | ||||
| Description |
| |||
Reaction | Class | 3 |
| ||
Solution | Class | 6 |
| ||
Parameter | %1: | Actual value [-] | |||
| |||||
Error type | - | ||||
| |||||
1000045 - 1000085 |
| |||
| Description | This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer. | ||
Reaction | Class | 3 |
| |
Solution | Class | 8 | Restart of NC-control necessary. | |
1000086 | Error while interpret the RT operating system settings. | |||
| Description |
| ||
Reaction | Class | 3 |
| |
Solution | Class | 7 |
| |
Error type | - | |||
| ||||
1000087 |
| |||
| Description | This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer. | ||
Reaction | Class | 3 |
| |
Solution | Class | 8 | Restart of NC-control necessary. | |
1000090 | The given startup procedure is unknown. | ||||
| Description |
| |||
Reaction | Class | 1 |
| ||
Solution | Class | 1 |
| ||
Parameter | %1: | Actual value [-] | |||
| |||||
%2: | Corrected value [-] | ||||
| |||||
Error type | - | ||||
| |||||
1000091 - 1000098 |
| |||
| Description | This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer. | ||
Reaction | Class | 3 |
| |
Solution | Class | 8 | Restart of NC-control necessary. | |
1000099 | Logical axes number dues not exist. | ||||
| Description | There is no axis configured with the given logical axis number. The order to accept the parameter by the control is rejected. | |||
Reaction | Class | 3 | The order to accept the parameter by the control is rejected. | ||
Solution | Class | 6 | New order with correct logical axis number. | ||
Parameter | %1: | Actual value [-] | |||
Unknown logical axis number | |||||
Error type | - | ||||
| |||||
1000100 / 1000101 |
| |||
| Description | This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer. | ||
Reaction | Class | 3 |
| |
Solution | Class | 8 | Restart of NC-control necessary. | |
1000103 | Error by register an OSACA SCO in COM. | |||
| Description |
| ||
Reaction | Class | 3 |
| |
Solution | Class | 7 |
| |
Error type | 5, Error message by access on files. | |||
| ||||
1000105 | No OSACA write access on OAM object possible. | |||
| Description |
| ||
Reaction | Class | 3 |
| |
Solution | Class | 7 |
| |
Error type | 5, Error message by access on files. | |||
| ||||
1000106 | Access mode unknown. | |||
| Description |
| ||
Reaction | Class | 3 |
| |
Solution | Class | 7 |
| |
Error type | 5, Error message by access on files. | |||
| ||||
1000107 | OSACA SCO could not be instantiated. | |||
| Description |
| ||
Reaction | Class | 3 |
| |
Solution | Class | 7 |
| |
Error type | 5, Error message by access on files. | |||
| ||||
1000108 | OSACA SCO type unknown. | |||
| Description |
| ||
Reaction | Class | 3 |
| |
Solution | Class | 7 |
| |
Error type | 5, Error message by access on files. | |||
| ||||
1000109 | OSACA SCO class unknown. | |||
| Description |
| ||
Reaction | Class | 3 |
| |
Solution | Class | 7 |
| |
Error type | 5, Error message by access on files. | |||
| ||||
1000110 | No mapping objekt definied. | |||
| Description |
| ||
Reaction | Class | 3 |
| |
Solution | Class | 1 |
| |
Error type | 5, Error message by access on files. | |||
| ||||
1000111 | Unkown OSACA process object | |||
| Description |
| ||
Reaction | Class | 3 |
| |
Solution | Class | 7 |
| |
Error type | 5, Error message by access on files. | |||
| ||||
1000112 | Size of array not consistence. | |||
| Description |
| ||
Reaction | Class | 3 |
| |
Solution | Class | 7 |
| |
Error type | 5, Error message by access on files. | |||
| ||||
1000113 | Size of buffer not consistence. | |||
| Description |
| ||
Reaction | Class | 3 |
| |
Solution | Class | 7 |
| |
Error type | 5, Error message by access on files. | |||
| ||||
1000115 | Overflow: size of buffer. | |||
| Description |
| ||
Reaction | Class | 3 |
| |
Solution | Class | 7 |
| |
Error type | 5, Error message by access on files. | |||
| ||||
1000116 | MCM-mode object not exist. | |||
| Description |
| ||
Reaction | Class | 3 |
| |
Solution | Class | 7 |
| |
Error type | 5, Error message by access on files. | |||
| ||||
1000117 | The data type of IDENT is wrong. | ||||
| Description |
| |||
Reaction | Class | 1 |
| ||
Solution | Class | 1 |
| ||
Parameter | %1: | Actual value [-] | |||
| |||||
%2: | Corrected value [-] | ||||
| |||||
%3: | Logical axis number [-] | ||||
| |||||
Error type | - | ||||
| |||||
1000119 | The possibel length of IDENT exceeds the limit. | ||||
| Description |
| |||
Reaction | Class | 1 |
| ||
Solution | Class | 1 |
| ||
Parameter | %1: | Actual value [-] | |||
| |||||
%2: | Corrected value [-] | ||||
| |||||
%3: | Logical axis number [-] | ||||
| |||||
Error type | - | ||||
| |||||
1000120 | The size of IDENT list is greater than 64 bytes. | ||||
| Description |
| |||
Reaction | Class | 1 |
| ||
Solution | Class | 1 |
| ||
Parameter | %1: | Actual value [-] | |||
| |||||
%2: | Corrected value [-] | ||||
| |||||
%3: | Logical axis number [-] | ||||
| |||||
Error type | - | ||||
| |||||
1000121 | The name of the file list is too long. | ||||
| Description |
| |||
Reaction | Class | 3 |
| ||
Solution | Class | 6 |
| ||
Parameter | %1: | Actual value [-] | |||
| |||||
%2: | Corrected value [-] | ||||
| |||||
%3: | Logical axis number [-] | ||||
| |||||
Error type | - | ||||
| |||||
1000122 | Cannot open the named file. | ||||
| Description |
| |||
Reaction | Class | 3 |
| ||
Solution | Class | 6 |
| ||
Parameter | %1: | Actual value [-] | |||
| |||||
%2: | Logical axis number [-] | ||||
| |||||
Error type | - | ||||
| |||||
1000123 | Illegal modificator. | ||||
| Description |
| |||
Reaction | Class | 1 |
| ||
Solution | Class | 1 |
| ||
Parameter | %1: | Actual value [-] | |||
| |||||
%2: | Corrected value [-] | ||||
| |||||
%3: | Logical axis number [-] | ||||
| |||||
Error type | - | ||||
| |||||
1000124 | Illegal phase for IDENT. | ||||
| Description |
| |||
Reaction | Class | 1 |
| ||
Solution | Class | 1 |
| ||
Parameter | %1: | Actual value [-] | |||
| |||||
%2: | Corrected value [-] | ||||
| |||||
%3: | Logical axis number [-] | ||||
| |||||
Error type | - | ||||
| |||||
1000127 - 1000129 |
| |||
| Description | This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer. | ||
Reaction | Class | 3 |
| |
Solution | Class | 8 | Restart of NC-control necessary. | |
1000130 | Interpretation of hardware configuration list failed. | |||
| Description |
| ||
Reaction | Class | 3 |
| |
Solution | Class | 7 |
| |
Error type | - | |||
| ||||
1000131 | Timeout while waiting for acknowledge of all hardware initialization tasks. | ||||
| Description |
| |||
Reaction | Class | 1 |
| ||
Solution | Class | 7 |
| ||
Parameter | %1: | Actual value [-] | |||
| |||||
%2: | Limit value [-] | ||||
| |||||
Error type | - | ||||
| |||||
1000132 |
| |||
| Description | This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer. | ||
Reaction | Class | 3 |
| |
Solution | Class | 8 | Restart of NC-control necessary. | |
1000133 | Initialization of interrupt logic not available. | |||
| Description |
| ||
Reaction | Class | 3 |
| |
Solution | Class | 1 |
| |
Error type | 3, Error message from communication. | |||
| ||||
1000134 | License server not available. | ||||
| Description |
| |||
Reaction | Class | 3 |
| ||
Solution | Class | 7 |
| ||
Parameter | %1: | Actual value [-] | |||
| |||||
Error type | - | ||||
| |||||
1000135 | License file not found. | ||||
| Description |
| |||
Reaction | Class | 3 |
| ||
Solution | Class | 7 |
| ||
Parameter | %1: | Actual value [-] | |||
| |||||
Error type | - | ||||
| |||||
1000136 | Syntax error in license file. | ||||
| Description |
| |||
Reaction | Class | 3 |
| ||
Solution | Class | 7 |
| ||
Parameter | %1: | Actual value [-] | |||
| |||||
Error type | - | ||||
| |||||
1000137 | Internal error during license key check. | ||||
| Description |
| |||
Reaction | Class | 3 |
| ||
Solution | Class | 7 |
| ||
Parameter | %1: | Actual value [-] | |||
| |||||
Error type | - | ||||
| |||||
1000138 | License key for function not valid. | ||||
| Description |
| |||
Reaction | Class | 3 |
| ||
Solution | Class | 7 |
| ||
Parameter | %1: | Actual value [-] | |||
| |||||
Error type | - | ||||
| |||||
1000139 | License key expired. | ||||
| Description |
| |||
Reaction | Class | 3 |
| ||
Solution | Class | 7 |
| ||
Parameter | %1: | Actual value [-] | |||
| |||||
Error type | - | ||||
| |||||
1000140 | Error by allocate of memory from the table administrator. | ||||
| Description |
| |||
Reaction | Class | 3 |
| ||
Solution | Class | 7 |
| ||
Parameter | %1: | Actual value [-] | |||
| |||||
Error type | - | ||||
| |||||
1000141 | Function to call specified twice in list. | |||
| Description |
| ||
Reaction | Class | 3 |
| |
Solution | Class | 7 |
| |
Error type | 6, Error message by data transfer into control device. | |||
| ||||
1000142 - 1000144 |
| |||
| Description | This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer. | ||
Reaction | Class | 3 |
| |
Solution | Class | 8 | Restart of NC-control necessary. | |
1000145 | The minimum timer period of the operation system could not be read. | ||||
| Description |
| |||
Reaction | Class | 3 |
| ||
Solution | Class | 7 |
| ||
Parameter | %1: | Actual value [1 µsec] | |||
| |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
1000146 | The time slice is to small. | ||||
| Description |
| |||
Reaction | Class | 3 |
| ||
Solution | Class | 7 |
| ||
Parameter | %1: | Incorrect value [1 µsec] | |||
| |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
1000147 | The time slice is not an integral multiple of the timer value | ||||
| Description |
| |||
Reaction | Class | 3 |
| ||
Solution | Class | 7 |
| ||
Parameter | %1: | Incorrect value [1 µsec] | |||
| |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
1000148 | One second divided by the time slice must be a integral value. | ||||
| Description |
| |||
Reaction | Class | 1 |
| ||
Solution | Class | 1 |
| ||
Parameter | %1: | Incorrect value [1 µsec] | |||
| |||||
%2: | Corrected value [1 µsec] | ||||
| |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
1000149 | The cycle time is to small. | ||||
| Description |
| |||
Reaction | Class | 3 |
| ||
Solution | Class | 7 |
| ||
Parameter | %1: | Incorrect value [1 µsec] | |||
| |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
1000150 | The ratio between cycle time and time slice is to small. | ||||
| Description |
| |||
Reaction | Class | 3 |
| ||
Solution | Class | 1 |
| ||
Parameter | %1: | Actual value [1 µsec] | |||
| |||||
%3: | Corrected value [1 µsec] | ||||
| |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
1000151 | NC-parameter minimum windows time is smaller than one time slice. | ||||
| Description |
| |||
Reaction | Class | 1 |
| ||
Solution | Class | 1 |
| ||
Parameter | %1: | Actual value [1 µsec] | |||
| |||||
%3: | Corrected value [1 µsec] | ||||
| |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
1000152 | The windows minimum time is to big. | ||||
| Description |
| |||
Reaction | Class | 1 |
| ||
Solution | Class | 1 |
| ||
Parameter | %1: | Incorrect value [1 µsec] | |||
| |||||
%2: | Corrected value [1 µsec] | ||||
| |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
1000153 | The cycle time is no integral multiple of the parametrised time slice. | ||||
| Description |
| |||
Reaction | Class | 1 |
| ||
Solution | Class | 1 |
| ||
Parameter | %1: | Incorrect value [1 µsec] | |||
| |||||
%2: | Corrected value [1 µsec] | ||||
| |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
1000154 | NC-parameter interrupt number is not specified. | |||
| Description |
| ||
Reaction | Class | 3 |
| |
Solution | Class | 7 |
| |
Error type | 2, Error message by data transfer from parameter list into control device. | |||
| ||||
1000155 | Interrupt vector not attachable. | ||||
| Description |
| |||
Reaction | Class | 3 |
| ||
Solution | Class | 7 |
| ||
Parameter | %1: | Actual value [-] | |||
| |||||
Error type | - | ||||
| |||||
1000156 | Cannot create semaphore "SEM_RAISE_IRQ". | |||
| Description |
| ||
Reaction | Class | 3 |
| |
Solution | Class | 7 |
| |
Error type | - | |||
| ||||
1000157 | Cannot create semaphore "SEM_DROP_IRQ". | |||
| Description |
| ||
Reaction | Class | 3 |
| |
Solution | Class | 7 |
| |
Error type | - | |||
| ||||
1000158 | Cycle time of interpolation task different to NC cycle time. | ||||
| Description |
| |||
Reaction | Class | 3 |
| ||
Solution | Class | 7 |
| ||
Parameter | %1: | Expected value [-] | |||
| |||||
Error type | 6, Error message by data transfer into control device. | ||||
| |||||
1000159 | To many axis as spindle configurated. | ||||
| Description | The maximum number of spindles is exceeded. Please take contact to the control vendor, if more spindles necessary. | |||
Reaction | Class | 3 | No startup possible | ||
Solution | Class | 7 | Reduce number of spindles | ||
Parameter | %1: | Actual value [-] | |||
Number of configured spindles | |||||
%2: | Limit value [-] | ||||
Maximum number of spindles possible | |||||
Error type | - | ||||
| |||||
1000160 / 1000161 |
| |||
| Description | This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer. | ||
Reaction | Class | 3 |
| |
Solution | Class | 8 | Restart of NC-control necessary. | |
1000162 | Error by loading the Cam Tables. | ||||
| Description |
| |||
Reaction | Class | 3 |
| ||
Solution | Class | 7 |
| ||
Parameter | %1: | Actual value [-] | |||
| |||||
%2: | Actual value [-] | ||||
| |||||
Error type | - | ||||
| |||||
1000163 |
| |||
| Description | This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer. | ||
Reaction | Class | 3 |
| |
Solution | Class | 8 | Restart of NC-control necessary. | |
1000164 | Type of variable must not be specified as subelement of structure. | |||
| Description |
| ||
Reaction | Class | 3 |
| |
Solution | Class | 1 |
| |
Error type | 6, Error message by data transfer into control device. | |||
| ||||
1000165 | Flexible array must content at least two subelement. | |||
| Description |
| ||
Reaction | Class | 3 |
| |
Solution | Class | 1 |
| |
Error type | 6, Error message by data transfer into control device. | |||
| ||||
1000166 | Error by parametrization of the event-manager with the hardware config. | ||||
| Description |
| |||
Reaction | Class | 3 |
| ||
Solution | Class | 7 |
| ||
Parameter | %1: | Actual value [-] | |||
| |||||
%2: | Actual value [-] | ||||
| |||||
Error type | - | ||||
| |||||
1000167 | Error by parametrization of the decoder with the hardware configuration. | ||||
| Description |
| |||
Reaction | Class | 3 |
| ||
Solution | Class | 7 |
| ||
Parameter | %1: | Actual value [-] | |||
| |||||
%2: | Actual value [-] | ||||
| |||||
Error type | - | ||||
| |||||
1000168 | Error: Parametrization of the driver for transmission to the remote hardware. | ||||
| Description |
| |||
Reaction | Class | 3 |
| ||
Solution | Class | 7 |
| ||
Parameter | %1: | Actual value [-] | |||
| |||||
%2: | Actual value [-] | ||||
| |||||
Error type | - | ||||
| |||||
1000169 | Forward-/backward drive not switch free. Contact control-device producer. | |||
| Description |
| ||
Reaction | Class | 1 |
| |
Solution | Class | 1 |
| |
Error type | - | |||
| ||||
1000170 - 1000172 |
| |||
| Description | This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer. | ||
Reaction | Class | 3 |
| |
Solution | Class | 8 | Restart of NC-control necessary. | |
1000173 | More SERCOS devices are defined as system can administrate. | |||
| Description |
| ||
Reaction | Class | 3 |
| |
Solution | Class | 7 |
| |
Error type | - | |||
| ||||
1000174 | Specified number of channels overstep the maximum number. | ||||
| Description |
| |||
Reaction | Class | 1 |
| ||
Solution | Class | 1 |
| ||
Parameter | %1: | Actual value [-] | |||
| |||||
%3: | Corrected value [-] | ||||
| |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
1000175 | Error by update of PLCopen resolution units. | ||||
| Description |
| |||
Reaction | Class | 3 |
| ||
Solution | Class | 7 |
| ||
Parameter | %1: | Actual value [-] | |||
| |||||
%2: | Actual value [-] | ||||
| |||||
Error type | - | ||||
| |||||
1000176 |
| |||
| Description | This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer. | ||
Reaction | Class | 3 |
| |
Solution | Class | 8 | Restart of NC-control necessary. | |