ID-range 1000000-1000249

1000000 - 1000043

 

 

Description

This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer.

Reaction

Class

3

 

Solution

Class

8

Restart of NC-control necessary.

1000044

PDU-job to interpret data list fails in decoder.

 

Description

 

Reaction

Class

3

 

Solution

Class

6

 

Parameter

%1:

Actual value [-]

 

Error type

-

 

1000045 - 1000085

 

 

Description

This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer.

Reaction

Class

3

 

Solution

Class

8

Restart of NC-control necessary.

1000086

Error while interpret the RT operating system settings.

 

Description

 

Reaction

Class

3

 

Solution

Class

7

 

Error type

-

 

1000087

Troubleshooting classes

 

Description

This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer.

Reaction

Class

3

 

Solution

Class

8

Restart of NC-control necessary.

1000090

The given startup procedure is unknown.

 

Description

 

Reaction

Class

1

 

Solution

Class

1

 

Parameter

%1:

Actual value [-]

 

%2:

Corrected value [-]

 

Error type

-

 

1000091 - 1000098

Troubleshooting classes

 

Description

This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer.

Reaction

Class

3

 

Solution

Class

8

Restart of NC-control necessary.

1000099

Logical axes number does not exist.

 

Description

There is no axis configured with the given logical axis number. The order to accept the parameter by the control is rejected.

Reaction

Class

3

The order to accept the parameter by the control is rejected.

Solution

Class

6

New order with correct logical axis number.

Parameter

%1:

Actual value [-]

Unknown logical axis number

Error type

-

 

1000100 / 1000101

Troubleshooting classes

 

Description

This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer.

Reaction

Class

3

 

Solution

Class

8

Restart of NC-control necessary.

1000103

Error by register an OSACA SCO in COM.

 

Description

 

Reaction

Class

3

 

Solution

Class

7

 

Error type

5, Error message by access on files.

 

1000105

No OSACA write access on OAM object possible.

 

Description

 

Reaction

Class

3

 

Solution

Class

7

 

Error type

5, Error message by access on files.

 

1000106

Access mode unknown.

 

Description

 

Reaction

Class

3

 

Solution

Class

7

 

Error type

5, Error message by access on files.

 

1000107

OSACA SCO could not be instantiated.

 

Description

 

Reaction

Class

3

 

Solution

Class

7

 

Error type

5, Error message by access on files.

 

1000108

OSACA SCO type unknown.

 

Description

 

Reaction

Class

3

 

Solution

Class

7

 

Error type

5, Error message by access on files.

 

1000109

OSACA SCO class unknown.

 

Description

 

Reaction

Class

3

 

Solution

Class

7

 

Error type

5, Error message by access on files.

 

1000110

No mapping object defined.

 

Description

 

Reaction

Class

3

 

Solution

Class

1

 

Error type

5, Error message by access on files.

 

1000111

Unknown OSACA process object

 

Description

 

Reaction

Class

3

 

Solution

Class

7

 

Error type

5, Error message by access on files.

 

1000112

Size of array not consistence.

 

Description

 

Reaction

Class

3

 

Solution

Class

7

 

Error type

5, Error message by access on files.

 

1000113

Size of buffer not consistence.

 

Description

 

Reaction

Class

3

 

Solution

Class

7

 

Error type

5, Error message by access on files.

 

1000115

Overflow: size of buffer.

 

Description

 

Reaction

Class

3

 

Solution

Class

7

 

Error type

5, Error message by access on files.

 

1000116

MCM-mode object not exist.

 

Description

 

Reaction

Class

3

 

Solution

Class

7

 

Error type

5, Error message by access on files.

 

1000117

The data type of IDENT is wrong.

 

Description

 

Reaction

Class

1

 

Solution

Class

1

 

Parameter

%1:

Actual value [-]

 

%2:

Corrected value [-]

 

%3:

Logical axis number [-]

 

Error type

-

 

1000119

The possible length of IDENT exceeds the limit.

 

Description

 

Reaction

Class

1

 

Solution

Class

1

 

Parameter

%1:

Actual value [-]

 

%2:

Corrected value [-]

 

%3:

Logical axis number [-]

 

Error type

-

 

1000120

The size of IDENT list is greater than 64 bytes.

 

Description

 

Reaction

Class

1

 

Solution

Class

1

 

Parameter

%1:

Actual value [-]

 

%2:

Corrected value [-]

 

%3:

Logical axis number [-]

 

Error type

-

 

Troubleshooting classes

1000121

The name of the file list is too long.

 

Description

 

Reaction

Class

3

 

Solution

Class

6

 

Parameter

%1:

Actual value [-]

 

%2:

Corrected value [-]

 

%3:

Logical axis number [-]

 

Error type

-

 

1000122

Cannot open the named file.

 

Description

 

Reaction

Class

3

 

Solution

Class

6

 

Parameter

%1:

Actual value [-]

 

%2:

Logical axis number [-]

 

Error type

-

 

1000123

Illegal modificator.

 

Description

 

Reaction

Class

1

 

Solution

Class

1

 

Parameter

%1:

Actual value [-]

 

%2:

Corrected value [-]

 

%3:

Logical axis number [-]

 

Error type

-

 

1000124

Illegal phase for IDENT.

 

Description

 

Reaction

Class

1

 

Solution

Class

1

 

Parameter

%1:

Actual value [-]

 

%2:

Corrected value [-]

 

%3:

Logical axis number [-]

 

Error type

-

 

1000127 - 1000129

 

 

Description

This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer.

Reaction

Class

3

 

Solution

Class

8

Restart of NC-control necessary.

1000130

Interpretation of hardware configuration list failed.

 

Description

 

Reaction

Class

3

 

Solution

Class

7

 

Error type

-

 

1000131

Timeout while waiting for acknowledge of all hardware initialization tasks.

 

Description

 

Reaction

Class

1

 

Solution

Class

7

 

Parameter

%1:

Actual value [-]

 

%2:

Limit value [-]

 

Error type

-

 

1000132

 

 

Description

This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer.

Reaction

Class

3

 

Solution

Class

8

Restart of NC-control necessary.

1000133

Initialization of interrupt logic not available.

 

Description

 

Reaction

Class

3

 

Solution

Class

1

 

Error type

3, Error message from communication.

 

1000134

License server not available.

 

Description

 

Reaction

Class

3

 

Solution

Class

7

 

Parameter

%1:

Actual value [-]

 

Error type

-

 

1000135

License file not found.

 

Description

 

Reaction

Class

3

 

Solution

Class

7

 

Parameter

%1:

Actual value [-]

 

Error type

-

 

1000136

Syntax error in license file.

 

Description

 

Reaction

Class

3

 

Solution

Class

7

 

Parameter

%1:

Actual value [-]

 

Error type

-

 

1000137

Internal error during license key check.

 

Description

 

Reaction

Class

3

 

Solution

Class

7

 

Parameter

%1:

Actual value [-]

 

Error type

-

 

1000138

License key for function not valid.

 

Description

 

Reaction

Class

3

 

Solution

Class

7

 

Parameter

%1:

Actual value [-]

 

Error type

-

 

1000139

License key expired.

 

Description

 

Reaction

Class

3

 

Solution

Class

7

 

Parameter

%1:

Actual value [-]

 

Error type

-

 

1000140

Error by allocate of memory from the table administrator.

 

Description

 

Reaction

Class

3

 

Solution

Class

7

 

Parameter

%1:

Actual value [-]

 

Error type

-

 

1000141

Function to call specified twice in list.

 

Description

 

Reaction

Class

3

 

Solution

Class

7

 

Error type

6, Error message by data transfer into control device.

 

1000142 - 1000144

 

 

Description

This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer.

Reaction

Class

3

 

Solution

Class

8

Restart of NC-control necessary.

1000145

The minimum timer period of the operation system could not be read.

 

Description

 

Reaction

Class

3

 

Solution

Class

7

 

Parameter

%1:

Actual value [1 µsec]

 

Error type

2, Error message by data transfer from parameter list into control device.

 

1000146

The time slice is to small.

 

Description

 

Reaction

Class

3

 

Solution

Class

7

 

Parameter

%1:

Incorrect value [1 µsec]

 

Error type

2, Error message by data transfer from parameter list into control device.

 

1000147

The time slice is not an integral multiple of the timer value

 

Description

 

Reaction

Class

3

 

Solution

Class

7

 

Parameter

%1:

Incorrect value [1 µsec]

 

Error type

2, Error message by data transfer from parameter list into control device.

 

1000148

One second divided by the time slice must be a integral value.

 

Description

 

Reaction

Class

1

 

Solution

Class

1

 

Parameter

%1:

Incorrect value [1 µsec]

 

%2:

Corrected value [1 µsec]

 

Error type

2, Error message by data transfer from parameter list into control device.

 

1000149

The cycle time is to small.

 

Description

 

Reaction

Class

3

 

Solution

Class

7

 

Parameter

%1:

Incorrect value [1 µsec]

 

Error type

2, Error message by data transfer from parameter list into control device.

 

1000150

The ratio between cycle time and time slice is too small.

 

Description

 

Reaction

Class

3

 

Solution

Class

1

 

Parameter

%1:

Actual value [1 µsec]

 

%3:

Corrected value [1 µsec]

 

Error type

2, Error message by data transfer from parameter list into control device.

 

1000151

NC-parameter minimum windows time is smaller than one time slice.

 

Description

 

Reaction

Class

1

 

Solution

Class

1

 

Parameter

%1:

Actual value [1 µsec]

 

%3:

Corrected value [1 µsec]

 

Error type

2, Error message by data transfer from parameter list into control device.

 

1000152

The windows minimum time is to big.

 

Description

 

Reaction

Class

1

 

Solution

Class

1

 

Parameter

%1:

Incorrect value [1 µsec]

 

%2:

Corrected value [1 µsec]

 

Error type

2, Error message by data transfer from parameter list into control device.

 

1000153

The cycle time is no integral multiple of the parametrized time slice.

 

Description

 

Reaction

Class

1

 

Solution

Class

1

 

Parameter

%1:

Incorrect value [1 µsec]

 

%2:

Corrected value [1 µsec]

 

Error type

2, Error message by data transfer from parameter list into control device.

 

1000154

NC-parameter interrupt number is not specified.

 

Description

 

Reaction

Class

3

 

Solution

Class

7

 

Error type

2, Error message by data transfer from parameter list into control device.

 

1000155

Interrupt vector not attachable.

 

Description

 

Reaction

Class

3

 

Solution

Class

7

 

Parameter

%1:

Actual value [-]

 

Error type

-

 

1000156

Cannot create semaphore "SEM_RAISE_IRQ".

 

Description

 

Reaction

Class

3

 

Solution

Class

7

 

Error type

-

 

1000157

Cannot create semaphore "SEM_DROP_IRQ".

 

Description

 

Reaction

Class

3

 

Solution

Class

7

 

Error type

-

 

1000158

Cycle time of interpolation task different to NC cycle time.

 

Description

 

Reaction

Class

3

 

Solution

Class

7

 

Parameter

%1:

Expected value [-]

 

Error type

6, Error message by data transfer into control device.

 

1000159

To many axis as spindle configurated.

 

Description

The maximum number of spindles is exceeded. Please take contact to the control vendor, if more spindles necessary.

Reaction

Class

3

No startup possible

Solution

Class

7

Reduce number of spindles

Parameter

%1:

Actual value [-]

Number of configured spindles

%2:

Limit value [-]

Maximum number of spindles possible

Error type

-

 

1000160 / 1000161

 

 

Description

This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer.

Reaction

Class

3

 

Solution

Class

8

Restart of NC-control necessary.

1000162

Error by loading the Cam Tables.

 

Description

 

Reaction

Class

3

 

Solution

Class

7

 

Parameter

%1:

Actual value [-]

 

%2:

Actual value [-]

 

Error type

-

 

1000163

 

 

Description

This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer.

Reaction

Class

3

 

Solution

Class

8

Restart of NC-control necessary.

1000164

Type of variable must not be specified as sub element of structure.

 

Description

 

Reaction

Class

3

 

Solution

Class

1

 

Error type

6, Error message by data transfer into control device.

 

1000165

Flexible array must content at least two sub elements.

 

Description

 

Reaction

Class

3

 

Solution

Class

1

 

Error type

6, Error message by data transfer into control device.

 

1000166

Error by parametrization of the event-manager with the hardware config.

 

Description

 

Reaction

Class

3

 

Solution

Class

7

 

Parameter

%1:

Actual value [-]

 

%2:

Actual value [-]

 

Error type

-

 

1000167

Error by parametrization of the decoder with the hardware configuration.

 

Description

 

Reaction

Class

3

 

Solution

Class

7

 

Parameter

%1:

Actual value [-]

 

%2:

Actual value [-]

 

Error type

-

 

1000168

Error: Parametrization of the driver for transmission to the remote hardware.

 

Description

 

Reaction

Class

3

 

Solution

Class

7

 

Parameter

%1:

Actual value [-]

 

%2:

Actual value [-]

 

Error type

-

 

1000169

Forward-/backward drive not switch free. Contact control-device producer.

 

Description

 

Reaction

Class

1

 

Solution

Class

1

 

Error type

-

 

1000170 - 1000172

Troubleshooting classes

 

Description

This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer.

Reaction

Class

3

 

Solution

Class

8

Restart of NC-control necessary.

1000173

More SERCOS devices are defined as system can administrate.

 

Description

 

Reaction

Class

3

 

Solution

Class

7

 

Error type

-

 

1000174

Specified number of channels overstep the maximum number.

 

Description

 

Reaction

Class

1

 

Solution

Class

1

 

Parameter

%1:

Actual value [-]

 

%3:

Corrected value [-]

 

Error type

2, Error message by data transfer from parameter list into control device.

 

1000175

Error by update of PLCopen resolution units.

 

Description

 

Reaction

Class

3

 

Solution

Class

7

 

Parameter

%1:

Actual value [-]

 

%2:

Actual value [-]

 

Error type

-

 

1000176

Troubleshooting classes

 

Description

This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer.

Reaction

Class

3

 

Solution

Class

8

Restart of NC-control necessary.