ID-range 292000-292249
ID-range 292000-292249
292000 |
| |||
| Description | This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer. | ||
Reaction | Class | 6 |
| |
Solution | Class | 8 | Restart of NC-control necessary. |
292001 | Kinematic transformation: Division by 0. | |||
| Description | Selection of kinematic transformation (#RTCP ON, #TRAFO ON) with wrong or incomplete parameters has lead to calculation error. If machine is not referenced this error also can occur because of wrong or invalid axis positions. Further information to kinematic transformation see [PROG], [KITRA]. | ||
Reaction | Class | - | Depending on module where error occurs - Program execution stop - Movement stop of axis | |
Solution | Class | - | Check axis positions, axis configuration and parameters of kinematic transformation. | |
Error type | - | |||
|
292002 | Kinematic transformation: Negative root. | |||
| Description | Selection of kinematic transformation (#RTCP ON, #TRAFO ON) with wrong or incomplete parameters has lead to calculation error. If machine is not referenced this error also can occur because of wrong or invalid axis positions. Further information to kinematic transformation see [PROG], [KITRA]. | ||
Reaction | Class | - | Depending on module where error occurs - Program execution stop - Movement stop of axis | |
Solution | Class | - | Check axis positions, correction of axis configuration and parameters of kinematic transformation. | |
Error type | - | |||
|
292003 | Kinematic transformation: Illegal argument for asin. | |||
| Description | Selection of kinematic transformation (#RTCP ON, #TRAFO ON) with wrong or incomplete parameters has lead to calculation error. If machine is not referenced this error also can occur because of wrong or invalid axis positions. Further information to kinematic transformation see [PROG], [KITRA] | ||
Reaction | Class | - | Depending on module where error occurs - Program execution stop - Movement stop of axis | |
Solution | Class | - | Check axis positions, correction of axis configuration and parameters of kinematic transformation. | |
Error type | - | |||
|
292004 | Kinematic transformation: Illegal argument for acos. | |||
| Description | Selection of kinematic transformation (#RTCP ON, #TRAFO ON) with wrong or incomplete parameters has lead to calculation error. If machine is not referenced this error also can occur because of wrong or invalid axis positions. Further information to kinematic transformation see [PROG], [KITRA]. | ||
Reaction | Class | - | Depending on module where error occurs - Program execution stop - Movement stop of axis | |
Solution | Class | - | Check axis positions, correction of axis configuration and parameters of kinematic transformation. | |
Error type | - | |||
|
292005 | Kinematic transformation: Illegal kinematic ID. | |||
| Description | Selection of kinematic transformation (#RTCP ON, #TRAFO ON) with invalid kinematic identifier. Further information to kinematic transformation see [PROG], [KITRA]. | ||
Reaction | Class | - | Depending on module where error occurs - Program execution stop - Movement stop of axis | |
Solution | Class | - | Use valid kinematic identifier in CNC command [#KIN ID] or if selection is done by tool selection in machine parameters of tool. | |
Error type | - | |||
|
292006 | Kinematic transformation: Transformation not available. | |||
| Description | With this kinematic.type and active kinematic transformation (#RTCP ON, #TRAFO ON) a utility functionality is not supported. Example: Use of #TOOL ORI CS command with tripod kinematic. wrong: %trafo N10 KIN ID[12] N20 #TRAFO ON N20 #TOOL ORI CS N30 G01 G90 X0 Y0 Z100 F2000 N40 M30 correct: %trafo N10 KIN ID[1] N20 #TRAFO ON N20 #TOOL ORI CS N30 G01 G90 X0 Y0 Z100 F2000 N40 M30 Further information to kinematic transformation see [PROG], [KITRA]. | ||
Reaction | Class | - | Depending on module where error occurs - Program execution stop - Movement stop of axis | |
Solution | Class | - | Do not use the utility functionality with this kinematic type. | |
Error type | - | |||
|
292007 | Kinematic transformation: Illegal vector. | |||
| Description | Selection of kinematic transformation (#RTCP ON, #TRAFO ON) with wrong or incomplete parameters has lead to calculation error. If machine is not referenced this error also can occur because of wrong or invalid axis positions. Further information to kinematic transformation see [PROG], [KITRA]. | ||
Reaction | Class | - | Depending on module where error occurs - Program execution stop - Movement stop of axis | |
Solution | Class | - | Check axis positions, correction of axis configuration and parameters of kinematic transformation. | |
Error type | - | |||
|
292008 | Kinematic transformation: Illegal angle phi. | |||
| Description | Moving to invalid axis positions with active kinematic transformation (#RTCP ON, #TRAFO ON). If machine is not referenced this error also can occur because of wrong or invalid axis positions. Further information to kinematic transformation see [PROG], [KITRA]. | ||
Reaction | Class | - | Depending on module where error occurs - Program execution stop - Movement stop of axis | |
Solution | Class | - | Move in valid axis position range. | |
Error type | - | |||
|
292009 | Kinematic transformation: Inadmissible number of transformation axes. | |||
| Description | The used CNC version does not support the selected kinematic transformation. Further information to kinematic transformation see [PROG], [KITRA]. | ||
Reaction | Class | - | Depending on module where error occurs - Program execution stop - Movement stop of axis | |
Solution | Class | - | Contact CNC manufacturer. | |
Error type | - | |||
|
292010 | Kinematic transformation: Inadmissible kinematic parameter. | |||
| Description | Selection of kinematic transformation (#RTCP ON, #TRAFO ON) with wrong or incomplete parameters has lead to calculation error. Further information to kinematic transformation see [PROG], [KITRA]. | ||
Reaction | Class | - | Depending on module where error occurs - Program execution stop - Movement stop of axis | |
Solution | Class | - | Check and correct parameters of kinematic transformation. | |
Error type | - | |||
|
292011 | Kinematic transformation: Inadmissible axis position. | |||
| Description | Selection of kinematic transformation (#RTCP ON, #TRAFO ON) with wrong or incomplete parameters has lead to calculation error. If machine is not referenced this error also can occur because of wrong or invalid axis positions. Further information to kinematic transformation see [PROG], [KITRA]. | ||
Reaction | Class | - | Depending on module where error occurs - Program execution stop - Movement stop of axis | |
Solution | Class | - | Check axis positions, correction of axis configuration and parameters of kinematic transformation. | |
Error type | - | |||
|
292012 | Kinematic transformation: Illegal argument for ATAN. | |||
| Description |
| ||
Reaction | Class | - |
| |
Solution | Class | - |
| |
Error type | - | |||
|
292013 | Kinematic transformation: Illegal argument for TAN. | |||
| Description | Moving to invalid axis positions with active kinematic transformation (#RTCP ON, #TRAFO ON). If machine is not referenced this error also can occur because of wrong or invalid axis positions. Further information to kinematic transformation see [PROG], [KITRA]. | ||
Reaction | Class | - | Depending on module where error occurs - Program execution stop - Movement stop of axis | |
Solution | Class | - | Move in valid axis position range. | |
Error type | - | |||
|
292014 | Kinematic transformation: Invalid WCS orientation. | |||
| Description |
| ||
Reaction | Class | - |
| |
Solution | Class | - |
| |
Error type | - | |||
|