ID-range 270000-270249

270000 / 270001

 

 

Description

This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer.

Reaction

Class

3

 

Solution

Class

8

Restart of NC-control necessary.

270018

Object does not exist.

 

Description

A communication object needed for startup is missing in the parameter lists for HMI-Objects or BF Channel.

This error only occurs, if the startup list is changed. The new parameterlists for HMI-objects or BF Channel are not complete.

Reaction

Class

3

 

Solution

Class

7

Setting parameter P-STUP-00024up to P-STUP-00027 to the default values, described in [STUP].

Error type

-

 

270021

Transition for this mode in actual state not allowed.

 

Description

The selected transition is not possible in the actual operation mode.In the documentation [HLI] (operation mode) is described, which transitions are allowed.

State diagramm for all operation modes

An easier way using the operation modes is to use an additional interface implemented called mode-state unit. The selected switch into the new mode and state will be done. All necessary transitions between the states (and the mode) is done by the control itself.

Reaction

Class

1

 

Solution

Class

1

Correct selection of the transition, which is possible in the actual state. Change of the order in the PLC or HMI.

Error type

-

 

270022

Unknown state or mode.

 

Description

The selected state in the order for switching the state or the operation mode is not known. The possible states are described in [HLI] (operation modes).

Reaction

Class

1

The order is rejected

Solution

Class

1

Change order by HMI or PLC

Error type

-

 

270023

Choosen mode is invalid.

 

Description

The choosen operation mode is not known. The operation modes are described in [HLI] (operation modes).

Reaction

Class

1

The request is ignored

Solution

Class

1

Change of the order and new request by HMI or PLC.

Error type

-

 

270024

Object cannot be written.

 

Description

The Request cannot be executed. The necessary communication object was not writeable.

One cause of the error message is a multiple request, which cannot be calculated in the actual cycle.

Reaction

Class

3

The request is ignored

Solution

Class

1

Send new request by HMI or PLC

Error type

-

 

270029 / 270030

 

 

Description

This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer.

Reaction

Class

3

 

Solution

Class

8

Restart of NC-control necessary.

270031

BF-Pin cannot connect with HLD from an axis.

 

Description

A BF could not be connected to the High Level Driver of the PLC interface.

Reaction

Class

3

Command is aborted.

Solution

Class

7

Restart system.

Error type

-

 

270032

BF-Pin cannot connect with HLD from CTM-plug.

 

Description

A BF could not be connected to the CTM.

Reaction

Class

3

Command is aborted.

Solution

Class

7

Restart system.

Error type

-

 

270033

Check reset of NC-channel without explict order over MCM.

 

Description

The NC-channel was commanded to do a reset, although the MCM did not command any.

Reaction

Class

1

Output of a warning.

Solution

Class

1

Check reset command.

Error type

-

 

270034 - 270036

 

 

Description

This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer.

Reaction

Class

3

 

Solution

Class

8

Restart of NC-control necessary.

270037

PLC-RUN-Mode: PLC must run before CNC startup.

 

Description

After startup of the control the cnc tests every cycle, in which control units of the HLI [HLI] enable is set or not. So the internal unit simulation is switched on or off, the HMI requests are send to the PLC or direct to the CNC.

With parameter P-STUP-00032it can be selected which units will be serviced by the PLC at startup time.A later registration is not possible.

It is necessary, that the PLC is started before startup of the CNC.

Reaction

Class

3

Transition in error state, no communication with PLC possible.

Solution

Class

7

Set parameters P-STUP-00032to 0.

Error type

-

 

270039

Initialisation of work data from HLDX (in PLC_RUN_MODE) failed.

 

Description

 

Reaction

Class

3

 

Solution

Class

7

 

Error type

-

 

270040

Initialisation of work data from HLDX (in PLC_RUN_MODE) failed.

 

Description

 

Reaction

Class

3

 

Solution

Class

7

 

Error type

-

 

270041

Initialisation of work data from HLDX (in PLC_TEST_MODE) failed.

 

Description

The initialization of the axis specific working data of the High Level Driver for the PLC interface failed.

Reaction

Class

3

Command is aborted.

Solution

Class

7

Restart system.

Error type

-

 

270042

Initialisation of work data from HLDX (in PLC_TEST_MODE) failed.

 

Description

 

Reaction

Class

3

 

Solution

Class

7

 

Error type

-

 

270045

 

 

Description

This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer.

Reaction

Class

3

 

Solution

Class

8

Restart of NC-control necessary.

270046

Interpreter cannot cannot evaluate the PLC-I/O-mapping list.

 

Description

There was an error during interpretation of the PLC-I/O mapping list, e.g. wrong token.

Reaction

Class

3

Command is aborted.

Solution

Class

1

Check PLC-I/O mapping list.

Error type

-

 

270047

Error while checking the new mapping list.

 

Description

An error was detected in the parameter of the new PLC-I/O mapping list.

Reaction

Class

3

Command is aborted.

Solution

Class

1

Check parameter in the new PLC-I/O mapping list.

Parameter

%1:

Actual value [-]

Current state of the interpreter.

Error type

-

 

270048

 

 

Description

This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer.

Reaction

Class

3

 

Solution

Class

8

Restart of NC-control necessary.

270049

No mapping declaration for SERCOS-Ident (output) found.

 

Description

There is no mapping rule configured in the PLC-I/O mapping list for the cyclic SERCOS output ident.

Reaction

Class

3

Command is aborted.

Solution

Class

1

Check PLC-I/O mapping list.

Parameter

%1:

Actual value [-]

Incorrect SERCOS ident.

Error type

-

 

270050

No mapping declaration for SERCOS-Ident (input) found.

 

Description

There is no mapping rule configured in the PLC-I/O mapping list for the cyclic SERCOS input ident.

Reaction

Class

3

Command is aborted.

Solution

Class

1

Check PLC-I/O mapping list.

Parameter

%1:

Actual value [-]

Incorrect SERCOS ident.

Error type

-

 

270051

Global transfer memory does not exist.

 

Description

The number of the I/O-devices could not be read, because there was no access to the global transfer memory.

Reaction

Class

3

Command is aborted.

Solution

Class

7

Restart the system.

Parameter

%1:

Actual value [-]

Size of PLC-I/O transfer memory.

Error type

-

 

270052

The I/O-interface of the PLC cannot be allocated.

 

Description

The shared memory to transport the cyclic PLC-I/O data between NC and PLC could not be allocated.

Reaction

Class

3

Command is aborted.

Solution

Class

7

Restart the system.

Parameter

%1:

Actual value [-]

Size of PLC-I/O transfer memory.

Error type

-

 

270053

CNC monitors PLC - No sign of life of PLC.

 

Description

The live counter of the PLC was tested cyclic by the CNC. The live counter test has failed, the PLC has exceeded the programmed runtime.

The PLC has activated the runtime test and doesn’t acknowledge the execution in the programmed time.

The runtime of the PLC has to be tested, the check time has to be adjusted ([HLI]).

Reaction

Class

-

 

Solution

Class

-

 

Error type

-

 

270054

 

 

Description

This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer.

Reaction

Class

3

 

Solution

Class

8

Restart of NC-control necessary.

270055

Interpreter cannot evaluate the device list.

 

Description

There is an error in the parameter of the device list.

Reaction

Class

1

Command is aborted.

Solution

Class

1

Check the parameter of the device list.

Error type

-

 

270056 / 270057

 

 

Description

This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer.

Reaction

Class

3

 

Solution

Class

8

Restart of NC-control necessary.

270059

The actual operation mode differs from the expected one.

 

Description

Requesting the operation mode / state switch, the actual operation mode differs from the expected one.

The operation mode switch will not be executed.

The values included in the mode-state unit [HLI] have to be corrected.

Possibilities:

1. Use of the correct operation mode (fromMode)

2. Setting this value to “0”. The operation mode switch will be executed independend on the actual operation mode.

Reaction

Class

3

The transition will not be done

Solution

Class

1

Correction of …FromMode in ModeState Unit

Create new request

Error type

-

 

270060

The actual state differs from the expected one.

 

Description

Requesting the operation mode / state switch, the actual state differs from the expected one.

The operation mode switch will not be executed.

The values included in the mode-state unit [HLI] have to be corrected.

Possibilities:

1. Use of the correct state (fromState)

2. Setting this value to “0”. The operation mode switch will be executed independend on the actual operation mode/state.

Reaction

Class

3

The transition will not be done

Solution

Class

1

Correction of …FromState in ModeState Unit

Create new request

Error type

-

 

270061

Given destination state in transition not allowed.

 

Description

The destination state in the transition order is not allowed or unknown. Which states are allowed in whoch operation mode is described in [HLI] (operation mode).

State diagramm of one operation mode

Reaction

Class

3

The transition will not be executed

Solution

Class

1

Correct the destination state and start new request

Error type

-

 

270062

Destination state could not be reached in an appropriate time.

 

Description

Switching in the destination state could not be done in the appropriate time. The timeout aborts the transition.

Reaction

Class

1

The transition is not completely done.

Solution

Class

1

New request of the transition

Error type

-

 

270063 - 270069

 

 

Description

This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer.

Reaction

Class

6

Command is aborted.

Solution

Class

8

Restart of NC-control necessary.

270070

An error message could not be written to the HLI (channel interface).

 

Description

The PLC has enabled the errormessage unit in the HLI (s. [HLI]). But the PLC task is to slow to get all errormessages. Therefor some of the errormessages get lost.

To read all errormessages by the PLC, the PLC-task should get higher priority and/or lower cycle time.

Reaction

Class

3

Creating a new errormessage

Solution

Class

7

The PLC-task should get higher priority and/or lower cycle time.

Parameter

%1:

Actual value [-]

Error-id of the missing errormessage

Error type

-

 

270071

An error message could not be written to the HLI (axis interface).

 

Description

The PLC has enabled the errormessage unit in the HLI (s. [HLI]). But the PLC task is to slow to get all errormessages. Therefor some of the errormessages get lost.

To read all errormessages by the PLC, the PLC-task should get higher priority and/or lower cycle time.

Reaction

Class

3

Creating a new errormessage

Solution

Class

7

The PLC-task should get higher priority and/or lower cycle time.

Parameter

%1:

Actual value [-]

Error-id of the missing errormessage

%2:

Logical axis number [-]

 

Error type

-

 

270073

No PDU-buffer for SERCOS service available.

 

Description

There is no PDU-buffer anymore for the PLC High Level Driver. Therefore the SERCOS service channel command cannot be posted.

Reaction

Class

3

Command is aborted.

Solution

Class

7

Do reset.

Error type

-

 

270074

Output of PDU for SERCOS service failed.

 

Description

The PLC High Level Driver could not send the SERCOS service channel command.

Reaction

Class

3

Command is aborted.

Solution

Class

7

Do reset.

Parameter

%1:

Logical axis number [-]

 

Error type

-

 

270075

 

 

Description

This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer.

Reaction

Class

3

 

Solution

Class

8

Restart of NC-control necessary.

270076

CNC-reset triggered by user.

 

Description

A CNC-reset was activated by the HMI or PLC.

This message will be created, if a transition causes a reset of the control.

By analysing this message, error events can be synchronized. Older errormessages are no longer valid.

Reaction

Class

-

-

Solution

Class

-

-

Error type

-

 

270077

Activation job for manual mode was not processed by PLC (control unit not empty).

 

Description

CNC tries to forward data from another application (e.g. HMI) to the PLC. The order contains data which device (e. g. key, handwheel) commands a specific axis in manual mode.

This order to link a device to an axis couldn’t sent via a control unit of the interface to the PLC within a defined number of CNC cyles, because the related control unit is occupied by a former order.

The PLC application has to be checked, to be sure that

1) the request semaphore of the control unit has to be set to FALSE after each transfer of data concerning an activation job for manual mode.

2) The PLC has cyclical to check if there are data in the control unit.

3) if you don’t want to handle activations jobs for manual mode by the PLC the enable flag of the concerning control unit is set to FALSE.

See [HLI], keyword „Activation of operating device“

Reaction

Class

3

 

Solution

Class

1

 

Error type

-

 

270078

Continuous jog parameter was not processed by PLC (control unit not empty).

 

Description

CNC tries to forward data to parametrize continuous jog to the PLC, which another application (e. g. HMI) sends. This data couldn’t be transmitted to the PLC via the interface within a defined number of CNC cycles, because the related control unit is occupied by former written parametrization data.

Reaction

Class

3

 

Solution

Class

1

The PLC application has to be checked, to be sure that

4) the request semaphore of the control unit has to be set to FALSE after the PLC took the parametrization data.

5) The PLC has cyclical to check if there are new data for parametrization in the control unit.

6) if you don’t want to handle keys by the PLC the enable flag of the concerning control unit is set to FALSE.

See [HLI], keyword „Programming Jog mode“

Error type

-

 

270079

Incremental jog parameter was not processed by PLC (control unit not empty).

 

Description

CNC tries to forward data to the PLC, which another application (e. g. HMI) sends, to parametrize incremental jog mode. This data couldn’t be transmitted to the PLC via the interface within a defined number of CNC cycles, because the related control unit is occupied by a former order to parametrize incremental jog mode.

The PLC application has to be checked, to be sure that

7) the request semaphore of the control unit is set to FALSE after each transfer of parametrization data into the PLC.

8) the PLC cyclical checks, if there are new parametrization data in the control unit.

9) if you don’t want to handle parametrization of incremental job mode by the PLC, the enable flag of the concerning control unit is set to FALSE.

See [HLI], keyword „ Programming Inching mode“

Reaction

Class

3

 

Solution

Class

1

 

Error type

-

 

270080

Handwheel parameter was not processed by PLC (control unit not empty).

 

Description

CNC tries to forward data to the PLC, which another application (e. g. HMI) sends, to parametrize handwheel mode. This data couldn’t be transferred to the PLC via the interface within a defined number of CNC cycles, because the related control unit is occupied by a former order to parametrize handwheel mode.

Reaction

Class

3

 

Solution

Class

1

The PLC application has to be checked, to be sure that

10) the request semaphore of the control unit is set to FALSE after each transfer of parametrization data into the PLC.

11) the PLC cyclical checks, if there are new parametrization data in the control unit.

12) if you don’t want to handle handwheel parametrization by the PLC the enable flag of the concerning control unit is set to FALSE.

See [HLI], keyword „ Programming handwheel mode”

Error type

-

 

270081

Key press was not processed by PLC (control unit not empty).

 

Description

CNC tries to forward data, about a pressed key to the PLC. The pressed key was detected within another application (e. g. HMI). The CNC couldn’t write the data within a defined number of CNC cycles into the interface to the PLC, because the related control unit is occupied by former data concerning a pressed key.

Reaction

Class

3

 

Solution

Class

1

The PLC application has to be checked, to be sure that

13) the request semaphore of the control unit is set to FALSE after each transfer of data concerning a pressed key into the PLC.

14) the PLC cyclical checks, if there are new data concerning a pressed key in the control unit.

15) if you don’t want to handle keys by the PLC the enable flag of the concerning control unit ist set to FALSE.

See [HLI], keyword „Ensuring compliance with a keystroke”

Error type

-

 

270082

Rapid mode key press was not processed by PLC (control unit not empty).

 

Description

CNC tries to forward data, about a pressed rapid key to the PLC. The pressed rapid key was detected within another application (e. g. HMI). The CNC couldn’t write the data within a defined number of CNC cycles into the interface to the PLC, because the related control unit is occupied by former data transfer concerning a pressed rapid key.

Reaction

Class

3

 

Solution

Class

1

The PLC application has to be checked, to be sure that

16) the request semaphore of the control unit is set to FALSE after each transfer of data concerning a pressed rapid key into the PLC.

17) the PLC cyclical checks, if there are new data concerning a pressed rapid key in the control unit.

18) if you don’t want to handle rapid key by the PLC, the enable flag of the concerning control is set to FALSE.

See [HLI], keyword „Rapid traverse speed during traverse motion”

Error type

-

 

270083 / 270085

 

 

Description

This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer.

Reaction

Class

6

 

Solution

Class

8

Restart of NC-control necessary.

270086

File name is too long.

 

Description

 

Reaction

Class

-

 

Solution

Class

-

 

Error type

-

 

270091

 

 

Description

This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer.

Reaction

Class

3

 

Solution

Class

8

Restart of NC-control necessary.

270092

BF-Pin cannot connect with HLD from I/O-station.

 

Description

A BF could not be connected to the High Level Driver of the PLC I/O-interface.

Reaction

Class

3

Command is aborted.

Solution

Class

7

Restart the system.

Error type

-

 

270093

Index of PLC-I/O-station exceeds limits.

 

Description

 

Reaction

Class

3

 

Solution

Class

1

 

Parameter

%1:

Actual value [-]

 

%2:

Lower limit value [-]

 

%3:

Upper limit value [-]

 

Error type

-

 

270094

Index of PLC-I/O-slots exceeds limits.

 

Description

 

Reaction

Class

3

 

Solution

Class

1

 

Parameter

%1:

Actual value [-]

 

%2:

Lower limit value [-]

 

%3:

Upper limit value [-]

 

Error type

-

 

270095

Index of PLC-I/O-data exceeds limits.

 

Description

 

Reaction

Class

3

 

Solution

Class

1

 

Parameter

%1:

Actual value [-]

 

%2:

Lower limit value [-]

 

%3:

Upper limit value [-]

 

Error type

-

 

270096

Trace of IPO data in zero channel configuration not possible.

 

Description

 

Reaction

Class

3

 

Solution

Class

1

 

Error type

-

 

270097

List contains unknown elements.

 

Description

During interpretation of the mapping list of the IO devices an unknown list element is detected.

Reaction

Class

1

 

Solution

Class

1

Remove or modify the unknown list element in the corresponding list.

Error type

-

 

270098 - 270102

 

 

Description

This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer.

Reaction

Class

3

 

Solution

Class

8

Restart of NC-control necessary.