ID-range 140000-140249
140000 - 140016 | ||||
| Description | This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer. | ||
Reaction | Class | 3 |
| |
Solution | Class | 8 | Restart of NC-control necessary. | |
140017 | Index of field data requested exceeds the limit of field definition. | ||||
| Description | The maximum permissible length of an ident was exceeded while reading the ident. | |||
Reaction | Class | 1 | Output of a warning. | ||
Solution | Class | 1 | Check length of the ident in the drive. | ||
Parameter | %1: | Actual value [-] | |||
Current length of the ident. | |||||
%2: | Limit value [-] | ||||
Maximum permissible length of an ident. | |||||
%3: | Actual value [-] | ||||
Index of the SERCOS axis. | |||||
%4: | Ident number [-] | ||||
Number of the ident. | |||||
Error type | - | ||||
| |||||
140018 | ||||
| Description | This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer. | ||
Reaction | Class | 3 |
| |
Solution | Class | 8 | Restart of NC-control necessary. | |
140021 | Start of procedure command not possible. | ||||
| Description | An error occurred during the execution of a command. | |||
Reaction | Class | 1 | Output of a warning. | ||
Solution | Class | 1 | Read error diagnostic of drive (ident 95). | ||
Parameter | %1: | Status [-] | |||
Logical axis number (P-AXIS-00016). | |||||
%2: | Logical axis number [-] | ||||
Number of the erroneous command. | |||||
%3: | Ident number [-] | ||||
| |||||
Error type | - | ||||
| |||||
140023 | Procedure command active for requested service channel. | |||
| Description | During the execution of a SERCOS-command was detected that the service channel was already occupied | ||
Reaction | Class | 1 | Output of a warning. | |
Solution | Class | 1 | Abort old command before starting new command. | |
Error type | - | |||
| ||||
140024 | A command which is requested to be erased is already erased. | ||||
| Description | A SERCOS-command that shall be erased is already erased. | |||
Reaction | Class | 1 | Output of a warning. | ||
Solution | Class | 1 |
| ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Ident number [-] | ||||
| |||||
Error type | - | ||||
| |||||
140025 | ||||
| Description | This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer. | ||
Reaction | Class | 3 |
| |
Solution | Class | 8 | Restart of NC-control necessary. | |
140026 | No device with this logical number available. | ||||
| Description |
| |||
Reaction | Class | 1 |
| ||
Solution | Class | 1 |
| ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
Error type | - | ||||
| |||||
140027 | Abort of procedure command not possible, because there is no command active. | ||||
| Description | No SERCOS procedure commands can be aborted, because there are no active commands present. | |||
Reaction | Class | 1 | Output of a warning. | ||
Solution | Class | 1 | No further action necessary. | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number (P-AXIS-00016). | |||||
Error type | - | ||||
| |||||
140028 | ||||
| Description | This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer. | ||
Reaction | Class | 3 |
| |
Solution | Class | 8 | Restart of NC-control necessary. | |
140029 | Error while phase switch to CP 0. | |||
| Description | An error occurred while switching to phase 0. | ||
Reaction | Class | 1 | Output of a warning. | |
Solution | Class | 1 | Check SERCOS ring: Ring closed Power supply for all drives switched on? | |
Error type | - | |||
| ||||
140030 | Error while phase switch to CP 1. | |||
| Description | The SERCOS ring could not be switched in phase 1. | ||
Reaction | Class | 1 | Output of warning. | |
Solution | Class | 1 |
| |
Error type | - | |||
| ||||
140031 | Error while phase switch to CP 2. | |||
| Description | The SERCOS ring could not be switched in phase 2. | ||
Reaction | Class | 1 | Output of warning. | |
Solution | Class | 1 |
| |
Error type | - | |||
| ||||
140032 | Error while reading ident. | |||
| Description | There was an error while trying to read an SERCOS ident from a drive. | ||
Reaction | Class | 1 | Output of a warning. | |
Solution | Class | 1 | Check if the ident that was tied to read is present in the drive. | |
Error type | - | |||
| ||||
140033 | Error while reading slave arrangement. | |||
| Description | SEROS- ident 96 (SLKN) could not be read from the drive. | ||
Reaction | Class | 1 | Output of a warning. | |
Solution | Class | 1 | Check if SERCOS ident 96 is supported by the drive. | |
Error type | - | |||
| ||||
140034 | Error while time slot calculation. | |||
| Description | The time slot calculation for the cyclic SERCOS telegram was not successful. | ||
Reaction | Class | 1 | Output of a warning. | |
Solution | Class | 1 | Check time slot parameter of the drive. | |
Error type | - | |||
| ||||
140035 | Error while writing an ident. | |||
| Description | An error occurred while writing a SERCOS ident. Possible reasons are: · Ident is not present in the drive · Ident is write protected by a password (see Ident 279, list of password protected data) · Ident can only be written in phase 2. | ||
Reaction | Class | 1 | Output of a warning. | |
Solution | Class | 1 | Cancel password protection (Ident 267) or switch to phase 2 before writing the ident. | |
Error type | - | |||
| ||||
140036 | Error while writing a drive telegram. | |||
| Description | An error occurred while writing the drive telegram in the drive. Possible reasons are:
| ||
Reaction | Class | 1 | Output of warning. | |
Solution | Class | 1 | Correction of the invalid values | |
Error type | - | |||
| ||||
140037 | Error while writing MDT start address (IDN 9). | |||
| Description | An error occurred while writing ident 9. | ||
Reaction | Class | 1 | Output of a warning. | |
Solution | Class | 1 |
| |
Error type | - | |||
| ||||
140038 | Error in transition check for communication phase 3 (command 127). | |||
| Description | SERCOS-command 127 (Preparation of switch to phase 3) returns with a error. This means that during the check of the parameters for phase 3 an invalid value was detected. A list with the idents of the invalid parameters can be read in ident 21 (list of invalid idents in phase 3). | ||
Reaction | Class | 1 | Output of warning. | |
Solution | Class | 1 | Read ident 21 (list of invalid idents in phase 3) and correct erroneous values. | |
Error type | - | |||
| ||||
140039 | Error while phase switch to CP 3. | |||
| Description | The SERCOS ring could not be switched in phase 3. | ||
Reaction | Class | 1 | Output of warning. | |
Solution | Class | 1 | Check parameters valid in phase 3 with the command ‚preparation of switch to phase 3’ (ident 127) and correct the erroneous values. | |
Error type | - | |||
| ||||
140040 | Error in transition check for communication phase 4 (command 128). | |||
| Description | SERCOS-command 128 (Preparation of switch to phase 4) returns with a error. This means that during the check of the parameters for phase 4 an invalid value was detected. A list with the idents of the invalid parameters can be read in ident 22 (list of invalid idents in phase 4). | ||
Reaction | Class | 1 | Output of warning. | |
Solution | Class | 1 | Read ident 22 (list of invalid idents in phase 4) and correct erroneous values. | |
Error type | - | |||
| ||||
140041 | Error while phase switch to CP 4. | |||
| Description | The SERCOS ring could not be switched in phase 4. | ||
Reaction | Class | 1 | Output of warning. | |
Solution | Class | 1 | Check parameters valid in phase 4 with the command ‚preparation of switch to phase 4’ (ident 128) and correct the erroneous values. | |
Error type | - | |||
| ||||
140042 | PDU with unknown logical axis number received. | ||||
| Description |
| |||
Reaction | Class | 1 |
| ||
Solution | Class | 1 |
| ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
Error type | 3, Error message from communication. | ||||
| |||||
140043 | PDU with invalid logical axis number received. | ||||
| Description |
| |||
Reaction | Class | 1 |
| ||
Solution | Class | 1 |
| ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
Error type | 3, Error message from communication. | ||||
| |||||
140047 |
| |||
| Description | This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer. | ||
Reaction | Class | 3 |
| |
Solution | Class | 8 | Restart of NC-control necessary. | |
140048 | You can switch to CP2 only in the moment. Instruction was corrected. | ||||
| Description | The service channel is still blocked by an action that was commanded before, so a communication phase switch can only be done to communication phase 2. Therefore the phase switch is stopped in communication phase 2. | |||
Reaction | Class | 1 | Output of a warning. | ||
Solution | Class | 1 | Abort the previous service channel command in communication phase 2 and then start phase switch again. | ||
Parameter | %1: | Actual value [-] | |||
Internal code for the commanded communication phase. | |||||
%2: | Corrected value [-] | ||||
Internal code for communication phase 2. | |||||
Error type | 3, Error message from communication. | ||||
| |||||
140050 | SERCOS-I/O channel type is not supported yet. | ||||
| Description |
| |||
Reaction | Class | 1 |
| ||
Solution | Class | 1 |
| ||
Parameter | %1: | Ident number [-] | |||
| |||||
%2: | Actual value [-] | ||||
| |||||
Error type | - | ||||
| |||||
140051 | Notice: Manufacturer specific SERCOS-I/O channel type. | ||||
| Description |
| |||
Reaction | Class | 1 |
| ||
Solution | Class | 1 |
| ||
Parameter | %1: | Ident number [-] | |||
| |||||
%2: | Actual value [-] | ||||
| |||||
Error type | - | ||||
| |||||
140052 | Given address of SERCOS-instruction (via PDU) is unknown. | ||||
| Description | The SERCOS service channel instruction cannot be executed, because the content of the instruction cannot be read. | |||
Reaction | Class | 1 | Output of a warning. | ||
Solution | Class | 1 |
| ||
Parameter | %1: | Actual value [-] | |||
Memory address to the content of the SERCOS instruction. | |||||
%2: | Expected value [-] | ||||
| |||||
%3: | Logical axis number [-] | ||||
| |||||
Error type | - | ||||
| |||||
140053 | Multiple use of same SERCOS drive address (configuration error). | ||||
| Description | In the configuration data two SERCOS axis are configured with the same drive address. | |||
Reaction | Class | 3 | Output error message, but nevertheless the operation is continued. | ||
Solution | Class | 6 | Check drive address in the configuration data. | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number of first axis (P-AXIS-00016). | |||||
%2: | Actual value [-] | ||||
Drive address of first axis(P-AXIS-00019). | |||||
%3: | Logical axis number [-] | ||||
Logical axis number of second axis (P-AXIS-00016). | |||||
%4: | Actual value [-] | ||||
Drive address of second axis(P-AXIS-00019) | |||||
Error type | - | ||||
| |||||
140054 | Timeout: Not terminated procedure command is aborted. | ||||
| Description |
| |||
Reaction | Class | 1 |
| ||
Solution | Class | 1 |
| ||
Parameter | %1: | Status [-] | |||
| |||||
%2: | Logical axis number [-] | ||||
| |||||
%3: | Ident number [-] | ||||
| |||||
%4: | Actual value [-] | ||||
| |||||
%5: | Upper limit value [-] | ||||
| |||||
Error type | - | ||||
| |||||