ID-range 130000-130249

130000 - 130006

Troubleshooting classes

 

Description

This error message informs about internal states, error solutions and the place of error in the source.Please give the complete error message data to the CNC manufacturer.

Reaction

Class

3

 

Solution

Class

8

Restart of NC-control necessary.

130007

Internal participant engaged maximum number of buffer locations.

 

Description

While sending a PDU the system participant cannot get any PDU-buffer anymore.

Reaction

Class

3

Output of a warning.

Solution

Class

1

Wait, because later there may be any PDU-buffer again and then repeat instruction.

Parameter

%1:

Actual value [-]

Current number of PDU buffers.

%2:

Expected value [-]

Maximum number of PDU buffers for this system participant.

Error type

-

 

130008 - 130104

Troubleshooting classes

 

Description

This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer.

Reaction

Class

3

 

Solution

Class

8

Restart of NC-control necessary.

130105

Timeout for writing PDU to receiver.

 

Description

The receiver doesn’t answers and doesn’t take the message.

Possible cause of this error is a PLC which runs to slow., but has enabled the message unit in the HLI.

Reaction

Class

1

 

Solution

Class

1

 

Parameter

%1:

Actual value [-]

 

Error type

3, Error message from communication.

 

130106

Timeout for writing PDU to receiver.

 

Description

The receiver doesn’t answers and doesn’t take the message.

Possible cause of this error is a PLC which runs to slow., but has enabled the message unit in the HLI.

Reaction

Class

1

 

Solution

Class

1

 

Parameter

%1:

Actual value [-]

 

Error type

3, Error message from communication.

 

130107 - 130119

Troubleshooting classes

 

Description

This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer.

Reaction

Class

3

 

Solution

Class

8

Restart of NC-control necessary.

130120

Invalid receiver of PDU-message.

 

Description

The message cannot be delivered to the receiver.

Check the programmed receiver ID in the #MSG order, possible use the documented [PROG] key words.

Reaction

Class

3

 

Solution

Class

3

 

Parameter

%1:

Actual value [-]

 

Error type

1, Error message from NC-program.

 

130121

Message can not be handled by receiver.

 

Description

The programmed receiver doesn’t understand the message. The message will be ignored.

Reaction

Class

1

 

Solution

Class

1

 

Parameter

%1:

Actual value [-]

 

Error type

3, Error message from communication.

 

130122 - 130124

Troubleshooting classes

 

Description

This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer.

Reaction

Class

3

 

Solution

Class

8

Restart of NC-control necessary.

130125

PDU-receiver not announced or unknown.

 

Description

The receiver of this message isn’t announced until now or is unknown. The message is undeliverable and ignored.

Possible cause of this error is an unknown receiver programmed in the #MSG-report.

Reaction

Class

3

 

Solution

Class

1

 

Parameter

%1:

Actual value [-]

 

%2:

Incorrect value [-]

 

%3:

Actual value [-]

 

%4:

Actual value [-]

 

%5:

Actual value [-]

 

Error type

3, Error message from communication.

 

130126

PDU not deliverable. PDU dismissed.

 

Description

The specified receiver doesn’t understand the message. He has sent the message back to the sender, who notices the message undeliverable.

Possible cause of the error is a wrong programmed receiver. The receiver didn’t understand the message

Reaction

Class

3

 

Solution

Class

3

 

Error type

3, Error message from communication.

 

130127

Participant already announced.

 

Description

Every communication participant has to announce after startup of the control. Then he can sent or receive messages.

A double announcement isn’t allowed, after next startup of the control the participant must register again.

Reaction

Class

1

 

Solution

Class

1

 

Parameter

%1:

Actual value [-]

 

Error type

-

 

130128 - 130133

Troubleshooting classes

 

Description

This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer.

Reaction

Class

3

 

Solution

Class

8

Restart of NC-control necessary.

130134

New SIGNAL/WAIT-event could not be saved.

 

Description

There are to much open signal- and wait-events. The control memory is full.

Depending on the configuration 50 / 100 open signal- and wait- events are possible [SYSP].

Reaction

Class

3

 

Solution

Class

7

Modify the cnc program and use less of synchronization events. Delete open synchronization events which are no longer used.

Parameter

%1:

Actual value [-]

 

Error type

3, Error message from communication.

 

130135

Troubleshooting classes

 

Description

This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer.

Reaction

Class

3

 

Solution

Class

8

Restart of NC-control necessary.