ID-range 120500-120749

120500

Not all three axes of CS known. No active wsp monitoring possible.

 

Description

To use the workspace monitoring the first three main axes must be defined. Then these are used as X, Y and Z coordinates for the workspace monitoring.

Reaction

Class

2

Stop NC program execution

Solution

Class

6

Check your axis configuration

Error type

1, Error message from NC-program.

 

120501 - 120503

 

 

Description

This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer.

Reaction

Class

3

 

Solution

Class

8

Restart of NC-control necessary.

120504

Interpreter cannot evaluate given list.

 

Description

The list interpreter cannot evaluate a given file path or list file name in the start-up list during start-up of the control. Possibly some of these data are wrong.

Reaction

Class

3

Start-up of the control is aborted.

Solution

Class

7

Check the way of writing of the corresponding file path or list file name and correct it if necessary.

Error type

-

 

120505

Error while transfer scene-/collision-MDS to Bavo.

 

Description

Because of wrong or unknown data, the list interpreter can not evaluate the collision/scene list.

Reaction

Class

3

Start-up of the control or data update is aborted.

Solution

Class

7

Check the entries in the collision/scene list and correct it if necessary.

Error type

-

 

120506 / 120507

Troubleshooting classes

 

Description

This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer.

Reaction

Class

3

 

Solution

Class

8

Restart of NC-control necessary.

120508

List contains unknown list element.

 

Description

During interpretation of the collision-/scene-lists an unknown list element is detected.

Reaction

Class

3

NC start-up is continued.

Solution

Class

7

Remove or modify the unknown list element in the corresponding list.

Error type

-

 

120509

Troubleshooting classes

 

Description

This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer.

Reaction

Class

3

 

Solution

Class

8

Restart of NC-control necessary.

120512

Distance between two solids in collision detection smaller than warn level.

 

Description

During movement of axes the minimal distance of two objects is below the specified limit. The limit is defined through the following NC-command #COLL DEF[PAIR<name> … WARNING<distance>].

Reaction

Class

1

Raising of warning

Solution

Class

1

Change movement or increase limit for warning

Parameter

%1:

Actual value [-]

Name of first object

%2:

Actual value [-]

Name of second object

%3:

Actual value [0.1 µm or 0,0001°]

Actual distance of both objects

%4:

Limit value [0.1 µm or 0,0001°]

Given minimal warning limit

Error type

1, Error message from NC-program.

 

120513

Distance between two solids in collision detection smaller than error level.

 

Description

During movement of axes the minimal distance of two objects is below the specified error limit. The limit is defined through the following NC-command #COLL DEF[PAIR<name> … ERROR<distance>].

Reaction

Class

2

Break of NC-Program or stop and “wait for continue”

Solution

Class

0

Change movement

Parameter

%1:

Actual value [-]

Name of first object

%2:

Actual value [-]

Name of second object

%3:

Actual value [0.1 µm or 0,0001°]

Actual distance of both objects

%4:

Limit value [0.1 µm or 0,0001°]

Given minimal error limit

Error type

1, Error message from NC-program.

 

120514

Troubleshooting classes

 

Description

This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer.

Reaction

Class

2

 

Solution

Class

8

Restart of NC-control necessary.

120515

Cancellation of request without axis registration.

 

Description

A wrong axis was requested and this request already stopped e.g. by a reset.

Reaction

Class

1

Warning, no reaction

Solution

Class

1

Check NC-program regarding axes exchange

Parameter

%1:

Logical axis number [-]

Number of wrong axis, requested before

Error type

3, Error message from communication.

 

120516

No active collision detection.

 

Description

 

Reaction

Class

1

 

Solution

Class

1

 

Error type

1, Error message from NC-program.

 

120517

 

 

Description

This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer.

Reaction

Class

2

 

Solution

Class

8

Restart of NC-control necessary.

120518

Leading angle outside of the permissible range of value.

 

Description

 

Reaction

Class

2

 

Solution

Class

3

 

Parameter

%1:

Incorrect value [0.1 µm or 0,0001°]

 

%2:

Upper limit value [0.1 µm or 0,0001°]

 

%3:

Lower limit value [0.1 µm or 0,0001°]

 

Error type

1, Error message from NC-program.

 

120519

Incline angle outside of the permissible range of value.

 

Description

 

Reaction

Class

2

 

Solution

Class

3

 

Parameter

%1:

Incorrect value [0.1 µm or 0,0001°]

 

%2:

Upper limit value [0.1 µm or 0,0001°]

 

%3:

Lower limit value [0.1 µm or 0,0001°]

 

Error type

1, Error message from NC-program.

 

120521

Incline angle changes sign.

 

Description

 

Reaction

Class

1

 

Solution

Class

1

 

Parameter

%1:

Actual value [0.1 µm or 0,0001°]

 

%2:

Actual value [0.1 µm or 0,0001°]

 

Error type

1, Error message from NC-program.

 

120522 / 120523

Troubleshooting classes

 

Description

This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer.

Reaction

Class

2

 

Solution

Class

8

Restart of NC-control necessary.

120524

Intermediate point of contour mode not within start-/end-/corner-point.

 

Description

The calculated intermediate point of the contour curve is not within the convex hull of start-, end- and corner point.

Reaction

Class

2

Raising of warning message

Solution

Class

1

Check contour curve

Parameter

%1:

Incorrect value [0.1 µm or 0,0001°]

X-coordinate of intermediate point

%3:

Incorrect value [0.1 µm or 0,0001°]

Z-coordinate of intermediate point

%5:

Block number [0.1 µm or 0,0001°]

Number of following block

Error type

1, Error message from NC-program.

 

120525

Synchronous operation in Mirror Link Mode not allowed with polynomials

 

Description

During definition of an axes coupling by #SET AX LINK or #AX LINK [NBR] a mirroring by factor = -1 was defined. This mirroring is not possible with active polynomial curve.

Reaction

Class

2

Abort of the NC program processing.

Solution

Class

6

Check NC-program and deselect mirroring or polynomial contouring

Error type

1, Error message from NC-program.

 

120526 - 120528

 

 

Description

This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer.

Reaction

Class

3

 

Solution

Class

8

Restart of NC-control necessary.

120529

#SCENE PRINT [FILE=<file>] not implemented.

 

Description

The NC-command #SCENE PRINT [FILE=<file>] just can be executed synchronous manner.

Reaction

Class

3

Break of NC-command

Solution

Class

1

Change NC-program

Error type

1, Error message from NC-program.

 

120530

A collision pair exists out of two valid added g-objects.

 

Description

In the definition of a collision pair in the collision list not both graphical objects names are given. For the correct definition two names are necessary.

Reaction

Class

2

Break of collision initialization

Solution

Class

6

Correct collision list

Parameter

%1:

Actual value [-]

Name of collision pair

Error type

-

 

120531

File extension of geometry file not known.

 

Description

The file extension of geometrical hull defined by NC-command #SCENE ADD[GOBJECT<> ... FILE<name >] is wrong. As extension “dcp” is expected.

Reaction

Class

2

Break of NC-program

Solution

Class

6

Check correct name of file

Parameter

%1:

Incorrect value

name of geometrical description of collision object

Error type

1, Error message from NC-program.

 

120532

Not found the graphical file in g-object definition.

 

Description

The file for the geometrical hull description defined by NC-command #SCENE ADD[GOBJECT<> ... FILE<name >] is not found.

Reaction

Class

2

Break of NC-program

Solution

Class

6

Check correct name of file

Parameter

%1:

Incorrect value

Filename of geometrical hull description

%2:

Actual value

Name of graphical object

%3:

Actual value

Path to file

Error type

1, Error message from NC-program.

 

120533

The file in definition of G-object is not the needed format (Decomposed).

 

Description

The file for the geometrical hull description defined by NC-command #SCENE ADD[GOBJECT<> ... FILE<name >] has a wrong internal data format.

Reaction

Class

2

Break of NC-program

Solution

Class

6

Check correct data format of file, decompose geometrical object again.

Parameter

%1:

Incorrect value

Filename of geometrical hull description

%2:

Actual value

Name of graphical object

Error type

1, Error message from NC-program.

 

120534

Troubleshooting classes

 

Description

This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer.

Reaction

Class

6

 

Solution

Class

8

Restart of NC-control necessary.

120536

Existing, active Pair could not be updated.

 

Description

It was tried to define a collision pair by the NC-command #COLL DEF [PAIR=<>...], which already was existing.

Reaction

Class

2

Break of NC-program

Solution

Class

6

Check NC-program

Parameter

%1:

Actual value

Name of first graphical object

%2:

Actual value

Name of second graphical object

%3:

Actual value

Name of collision pair

Error type

1, Error message from NC-program.

 

120537

Graphical object for defining collision pair not found in scene database.

 

Description

The specified graphical object in the collision list already does not exist. The collision pair could not be generated.

Reaction

Class

2

Break of execution

Solution

Class

6

 

Parameter

%1:

Incorrect value [-]

Name of graphical object

%2:

Actual value [-]

Name of collision pair

Error type

-

 

120539

Max number of collisions pairs reached.

 

Description

The maximum number of collision pair is reached. No more pairs can be defined.

Reaction

Class

2

Break of execution

Solution

Class

6

Reduce number of collision pairs

Parameter

%1:

Actual value

Actual number of pairs

%2:

Incorrect value

Maximum number of pairs

Error type

1, Error message from NC-program.

 

120540

Max number of g-objects in collision detection reached.

 

Description

The maximum number of graphical objects is reached. No more graphical objects can be defined.

Reaction

Class

2

Break of execution

Solution

Class

6

Reduce number of graphical elements

Parameter

%1:

Actual value

Actual number of graphical elements

%2:

Incorrect value

Maximum number of graphical elements

Error type

1, Error message from NC-program.

 

120541

 

 

Description

This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer.

Reaction

Class

2

 

Solution

Class

8

Restart of NC-control necessary.

120542

Parameter change during active b-spline interpolation not possible.

 

Description

During active B-spline no change of B-spline parameters is possible (e.g. #HSC [BSPLINE TRACK_DEV=5 MERGE=0 AUTO_OFF_PATH=1]). Please turn off B-spline before parameters are changed.

Reaction

Class

1

The new value of the parameter is dismissed

Solution

Class

1

Change of NC-program

Parameter

%1:

Block number [-]

Block number of parameter change

%2:

Actual value [-]

Parametertype:

0x0040 PATH_DEV
0x0080 TRACK_DEV
0x0100 MAX_PATH_LENGTH
0x0200 MAX_ANGLE
0x0400 AUTO_OFF_G00
0x0800 MERGE_DEV
0x1000 MERGE_RETRY
0x2000 MERGE_WINDOW
0x4000 PATH_SPLIT or AUTO_OFF_PATH

0x8000 TRACK_SPLIT or AUTO_OFF_TRACK

0x10000 LIMIT_CORNER_DIST

%3:

Actual value [-]

Actual value of parameter

%4:

Incorrect value [-]

Wanted, new value of parameter

Error type

1, Error message from NC-program.

 

120543

 

 

Description

This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer.

Reaction

Class

2

 

Solution

Class

8

Restart of NC-control necessary.

120544

Given number of blocks for merge above limit.

 

Description

The maximum number of blocks for merging is above the internal limit (see #HSC [ ... MERGE_WINDOW<number>]).

Reaction

Class

1

New parameter for merge window is dismissed

Solution

Class

1

Reduce given merge window

Parameter

%1:

Block number [-]

Block number of parameter change

%2:

Actual value [-]

Actual value of parameter

%3:

Limit value [-]

Maximum size of merge window

%4:

Corrected value [-]

Limited, new value

Error type

1, Error message from NC-program.

 

120545 - 120547

Troubleshooting classes

 

Description

This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer.

Reaction

Class

2

 

Solution

Class

8

Restart of NC-control necessary.

120548

Buffer of FIFO is full.

 

Description

In CNC program sequence there are too many non-relevant blocks between two movement blocks which must be processed by pre segmentation. Non relevant blocks are CNC program blocks without movement information. M codes, parameter calculation or subprogram calls leads to non-relevant blocks. With too many non-relevant blocks internal buffer memory is limiting and spline interpolation cannot be done.

Reaction

Class

2

Program execution stop.

Solution

Class

6

Check CNC program, reduction of M codes, subprogram calls and parameter calculation between spline interpolation movement blocks.

Error type

1, Error message from NC-program.

 

120549 / 120550

Troubleshooting classes

 

Description

This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer.

Reaction

Class

3

 

Solution

Class

8

Restart of NC-control necessary.

120551

G-object is too complex for collision detection

 

Description

The number of faces or vertices is above the internal limit. By this limitation it is guaranteed that the collision detection may not handle to complex graphical objects.

Reaction

Class

2

Break of NC-program

Solution

Class

6

Reduce resolution of graphical object

Parameter

%1:

Actual value

Name of graphical object

%2:

Actual value

Actual number of faces and vertices

%3:

Limit value

Maximum number of faces and vertices

Error type

1, Error message from NC-program.

 

120552 / 120553

Troubleshooting classes

 

Description

This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer.

Reaction

Class

2

 

Solution

Class

8

Restart of NC-control necessary.

120554

Mirror link operation mode not allowed with oscillation axis

 

Description

The oscillation functionality (Z[OSC ON..]) is part of the axis specific functionalities of the CNC channel, the axis moves independently of the path axes. That´s the reason why path functionalities as soft gantry (#ENABLE AX LINK) are not supported fully.

The error is generated because soft gantry with link factor –1 is activated (mirror link mode) and the master axis is the oscillation axis. Soft gantry then only is possible if the link factor is 1.

Further information to soft gantry functionality see [PROG].

Reaction

Class

2

Program execution stop.

Solution

Class

6

Check CNC program and correct link operation mode (#SET AXLINK[]).

Parameter

%1:

Logical axis number [-]

Logical axis number of soft gantry slave axis.

%2:

Actual value [-]

Actual selected link operation mode of soft gantry.

Error type

1, Error message from NC-program.

 

120555

Preceding segment during BSpline calculation unknown, even start point is modified.

 

Description

 

Reaction

Class

2

 

Solution

Class

1

 

Error type

1, Error message from NC-program.

 

120556

Output of BSpline-segment without check of deviation.

 

Description

A B-spline segment is ready to be moved, but deviation of this segment not already has been checked.

Reaction

Class

2

Break of program execution

Solution

Class

6

Check maximum deviation in CNC program

Error type

1, Error message from NC-program.

 

120557

Could not allocate new BSpline-segment.

 

Description

During internal consideration of B-spline segments the next segment could not be allocated.

Reaction

Class

2

Break of NC-program

Solution

Class

6

E.g. force output of segments by reducing of MERGE_WINDOW.

Error type

1, Error message from NC-program.

 

120558

 

 

Description

This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer.

Reaction

Class

2

 

Solution

Class

8

Restart of NC-control necessary.

120559

Maximum number of buffer slots reached. Oldest segment is released.

 

Description

During preparation of B-spline segments for merge, the maximum number of segments has been reached.

Reaction

Class

1

Warning

Solution

Class

1

E.g. force output of segments by reducing of MERGE_WINDOW.

Error type

1, Error message from NC-program.

 

120560 / 120561

 

 

Description

This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer.

Reaction

Class

2

 

Solution

Class

8

Restart of NC-control necessary.

120562

Error during writing in file.

 

Description

Error during writing of scene/collisions file. The action has been initiated by a previous #SCENE PRINT SYN [FILE=<name>] or #COLL PRINT [FILE=<name>] command.

Reaction

Class

1

Warning

Solution

Class

1

Check name and path of output file

Parameter

%1:

Actual value [-]

Name of output file

Error type

1, Error message from NC-program.

 

120563

The weighting factor for jerk is oversize.

 

Description

The HSC-factor for weighting of jerk P-CHAN-00143 ( see hsc.gen.jerk_weighting in [0.1%]) is below minimum.

Reaction

Class

1

Warning

Solution

Class

1

Value is limited to minimum

Parameter

%1:

Actual value [0,1%]

Specified value

%2:

Limit value [0,1%]

 

%3:

Corrected value [0,1%]

 

Error type

-

 

120564

The minimum block length for dynamic segmentation is undersize.

 

Description

The HSC-value for relevant block length is below minimum limit. (see. hsc.gen.min_segment_length in [0.1um]). Blocks below this length are not further divided for dynamical considerations.

Reaction

Class

1

Warning

Solution

Class

1

Value is limited to minimum

Parameter

%1:

Actual value [0.1 µm or 0,0001°]

 

%2:

Limit value [0.1 µm or 0,0001°]

 

%3:

Corrected value [0.1 µm or 0,0001°]

 

Error type

-

 

120566

The contouring mode is only possible in the default config. of feed axis.

 

Description

For G61-contour mode the feed rate must be mapped by the first three coordinate-system axes.

Reaction

Class

2

Break of program

Solution

Class

6

Check of default setting in channel list P-CHAN-00011or #FGROUP-programing.

Parameter

%1:

Logical axis number [-]

Axis of with incorrect setting

%2:

Incorrect value [-]

 

%3:

Expected value [-]

 

Error type

1, Error message from NC-program.

 

120567

The change of feed axis is impossible by active contouring mode.

 

Description

The mapping of feed rate to the axis may not be changed during active G61 contour mode (see #FGROUP).

Reaction

Class

2

Break of program

Solution

Class

6

Check of default setting in channel list P-CHAN-00011or #FGROUP-programing.

Parameter

%1:

Logical axis number [-]

 

%2:

Block number [-]

Number of previous block in block transition

%3:

Actual value [-]

Setting in actual block, defining if axis is mapped to feed rate

%4:

Expected value [-]

Setting in previous block, defining if axis is mapped to feed rate

Error type

1, Error message from NC-program.

 

120568 / 120569

Troubleshooting classes

 

Description

This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer.

Reaction

Class

2

 

Solution

Class

8

Restart of NC-control necessary.

120570

Weighting factor for jerk is oversized.

 

Description

The HSC-factor for weighting of jerk P-CHAN-00143 (see hsc.gen.jerk_weighting in [0.1%]) is above maximum.

Reaction

Class

1

Warning

Solution

Class

1

Value is limited to maximum

Parameter

%1:

Actual value [0,1%]

Specified value

%2:

Limit value [0,1%]

 

%3:

Corrected value [0,1%]

 

Error type

-

 

120571

Weighting factor for jerk with kinem. transformation is undersized.

 

Description

The HSC-factor for weighting of jerk with kinematic transformation P-CHAN-00142 (see hsc.gen.jerk_weighting_5ax in [0.1%]) is below minimum.

Reaction

Class

1

Warning

Solution

Class

1

Value is limited to minimum

Parameter

%1:

Actual value [0,1%]

Specified value

%2:

Limit value [0,1%]

 

%3:

Corrected value [0,1%]

 

Error type

-

 

120572

Weighting factor for jerk with kinem. transformation is oversized.

 

Description

The HSC-factor for weighting of jerk with kinematic transformation P-CHAN-00142 (seehsc.gen.jerk_weighting_5ax in [0.1%]) is above maximum.

Reaction

Class

1

Warning

Solution

Class

1

Value is limited to maximum

Parameter

%1:

Actual value [0,1%]

Specified value

%2:

Limit value [0,1%]

 

%3:

Corrected value [0,1%]

 

Error type

-

 

120573

Leading angle of the end mill near zero.

 

Description

 

Reaction

Class

2

 

Solution

Class

3

 

Parameter

%1:

Incorrect value [0.1 µm or 0,0001°]

 

%2:

Upper limit value [0.1 µm or 0,0001°]

 

%3:

Lower limit value [0.1 µm or 0,0001°]

 

%4:

Upper limit value [0.1 µm or 0,0001°]

 

%5:

Lower limit value [0.1 µm or 0,0001°]

 

Error type

1, Error message from NC-program.

 

120574 / 120576

Troubleshooting classes

 

Description

This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer.

Reaction

Class

2

 

Solution

Class

8

Restart of NC-control necessary.

120577

Front-tracking inside the collisions monitoring removed.

 

Description

 

Reaction

Class

1

 

Solution

Class

1

 

Parameter

%1:

Actual value [-]

 

%2:

Actual value [-]

 

Error type

1, Error message from NC-program.

 

120578

 

 

Description

This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer.

Reaction

Class

6

 

Solution

Class

8

Restart of NC-control necessary.

120579

Plane change in work or protection area definition not permitted.

 

Description

A plane change within the definition of a work or protection area (s. [FCT-C14]) is not allowed.

Example:

#CONTROL AREA START [ID1 PROT CIRC MIN_EXCUR=-50 MAX_EXCUR=50]
G01 Y100 Z100 F1000
G19
G02 G162 Y100 Z100 J-100 F1000
#CONTROL AREA END

Correct:

G19
#CONTROL AREA START [ID1 PROT CIRC MIN_EXCUR=-50 MAX_EXCUR=50]
G01 Y100 Z100 F1000
G02 G162 Y100 Z100 J-100 F1000
#CONTROL AREA END

Reaction

Class

2

Break of execution

Solution

Class

6

Correction of NC program

Parameter

%1:

Ident number [-]

Identifier of affected work or protection area

Error type

1, Error message from NC-program.

 

120580 / 120581

Troubleshooting classes

 

Description

This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer.

Reaction

Class

2

 

Solution

Class

8

Restart of NC-control necessary.

120582

Maximum number of transformed work/protection areas exceeded.

 

Description

 

Reaction

Class

2

 

Solution

Class

6

 

Parameter

%1:

Ident number [-]

 

%2:

Incorrect value [-]

 

%3:

Upper limit value [-]

 

Error type

1, Error message from NC-program.

 

120583

Troubleshooting classes

 

Description

This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer.

Reaction

Class

2

 

Solution

Class

8

Restart of NC-control necessary.

120585

License: too much axes shall move at the same time.

 

Description

 

Reaction

Class

2

 

Solution

Class

7

 

Parameter

%1:

Limit value [-]

 

Error type

1, Error message from NC-program.

 

120586

Necessary function of path preparation not enabled in CNC-configuration list.

 

Description

 

Reaction

Class

2

 

Solution

Class

7

 

Parameter

%1:

Expected value [-]

 

%2:

Expected value [-]

 

%3:

Actual value [-]

 

%4:

State [-]

 

Error type

1, Error message from NC-program.

 

120587 - 120600

Troubleshooting classes

 

Description

This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer.

Reaction

Class

3

 

Solution

Class

8

Restart of NC-control necessary.

120602

<axis>[LIFT_END] programmed, althought no LIFT-movement started.

 

Description

 

Reaction

Class

2

 

Solution

Class

6

 

Error type

1, Error message from NC-program.

 

120603

Bound axis must not be programmed during bound movement.

 

Description

 

Reaction

Class

2

 

Solution

Class

6

 

Error type

1, Error message from NC-program.

 

120604

LIFT-movement START is not allowed to programmed by running LIFT-movement.

 

Description

 

Reaction

Class

2

 

Solution

Class

6

 

Error type

1, Error message from NC-program.

 

120605

Different axis by <axis>[LIFT_START] and <axis>[LIFT_END] programmed.

 

Description

 

Reaction

Class

2

 

Solution

Class

6

 

Error type

1, Error message from NC-program.

 

120606

Programmed NC-block is not allowed by active LIFT-movement.

 

Description

 

Reaction

Class

2

 

Solution

Class

6

 

Error type

1, Error message from NC-program.

 

120607

Axis-change of active LIFT-axis not allowed.

 

Description

 

Reaction

Class

2

 

Solution

Class

6

 

Error type

1, Error message from NC-program.

 

120608

 

 

Description

This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer.

Reaction

Class

2

 

Solution

Class

8

Restart of NC-control necessary.

120609

In this moment a selection by LIFT segments in block START by block search possible.

 

Description

 

Reaction

Class

2

 

Solution

Class

6

 

Error type

1, Error message from NC-program.

 

120611

In this moment in the LIFT-segments is a Akima-Spline not allowed.

 

Description

 

Reaction

Class

2

 

Solution

Class

6

 

Error type

1, Error message from NC-program.

 

120613

Error in the contour calculation for the lift movement.

 

Description

 

Reaction

Class

2

 

Solution

Class

6

 

Error type

1, Error message from NC-program.

 

120614

 

 

Description

This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer.

Reaction

Class

2

 

Solution

Class

8

Restart of NC-control necessary.

120615

Programming of MNS_NS with/without pre-output not possible in the same NC-block.

 

Description

 

Reaction

Class

2

 

Solution

Class

6

 

Error type

1, Error message from NC-program.

 

120617

It is impossible to produce a poly channel block type.

 

Description

 

Reaction

Class

2

 

Solution

Class

6

 

Error type

1, Error message from NC-program.

 

120618

Error in the index administration.

 

Description

 

Reaction

Class

2

 

Solution

Class

6

 

Error type

1, Error message from NC-program.