ID-range 110000-110249
110005 - 110033 |
| |||
| Description | This error message informs about internal states, error solutions and the place of error in the source.Please give the complete error message data to the CNC manufacturer. | ||
Reaction | Class | 2 |
| |
Solution | Class | 8 | Restart of NC-control necessary. | |
110034 | Illegal denominator for damping value. | ||||
| Description | The Eigen-damping (denominator) of simulation drives was initialized invalid. | |||
Reaction | Class | 1 | Element is initialized by default value. | ||
Solution | Class | 1 | Correct parameter list of axis. | ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Incorrect value [-] | ||||
| |||||
%3: | Limit value [-] | ||||
| |||||
%4: | Corrected value [-] | ||||
| |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110035 | Illegal numerator for damping value. | ||||
| Description | The damping (numerator) of simulation drives was initialized invalid. | |||
Reaction | Class | 1 | Element is initialized by default value. | ||
Solution | Class | 1 | Correct parameter list of axis. | ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Incorrect value [-] | ||||
| |||||
%3: | Limit value [-] | ||||
| |||||
%4: | Corrected value [-] | ||||
| |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110036 | Illegal denominator for inner frequency. | ||||
| Description | The Eigen-frequency (denominator) of simulation drives was initialized not valid. | |||
Reaction | Class | 1 | Element is initialized by default value. | ||
Solution | Class | 1 | Correct parameter list of axis. | ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Incorrect value [-] | ||||
| |||||
%3: | Limit value [-] | ||||
| |||||
%4: | Corrected value [-] | ||||
| |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110037 | Illegal numerator for inner frequency. | ||||
| Description | The Eigen-frequency (numerator) of simulation drives was initialized not valid. | |||
Reaction | Class | 1 | Element is initialized by default value. | ||
Solution | Class | 1 | Correct parameter list of axis. | ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Incorrect value [-] | ||||
| |||||
%3: | Limit value [-] | ||||
| |||||
%4: | Corrected value [-] | ||||
| |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110038 | Illegal denominator for time constant. | ||||
| Description | The time constant (denominator) of simulation drives was initialized invalid. | |||
Reaction | Class | 1 | Element is initialized by default value. | ||
Solution | Class | 1 | Correct parameter list of axis. | ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Incorrect value [-] | ||||
| |||||
%3: | Limit value [-] | ||||
| |||||
%4: | Corrected value [-] | ||||
| |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110039 | Illegal numerator for time constant. | ||||
| Description | The time constant (numerator) of simulation drives was initialized not valid. | |||
Reaction | Class | 1 | Element is initialized by default value. | ||
Solution | Class | 1 | Correct parameter list of axis. | ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Incorrect value [-] | ||||
| |||||
%3: | Limit value [-] | ||||
| |||||
%4: | Corrected value [-] | ||||
| |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110040 | Simu drive: dead time exceeds maximum limit. | ||||
| Description | The dead time of simulation drives was initialized invalid. | |||
Reaction | Class | 1 | Element is initialized by default value. | ||
Solution | Class | 1 | Correct parameter list of axis. | ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Incorrect value [-] | ||||
| |||||
%3: | Limit value [-] | ||||
| |||||
%4: | Corrected value [-] | ||||
| |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110041 | Simu drive: amplification factor is 0. | ||||
| Description | The proportional gain for simulation drives was set to zero. This is an illegal value. | |||
Reaction | Class | 1 | Element is initialized by default value. | ||
Solution | Class | 1 | Correct parameter list of axis. | ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Incorrect value [0.01/sec] | ||||
| |||||
%3: | Corrected value [0.01/sec] | ||||
| |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110042 | D/A-converter resolution is illegal (numerator). | ||||
| Description | The resolution for the digital/analog converter (numerator) is specified with zero. This value is illegal. | |||
Reaction | Class | 1 | Element is initialized by default value. | ||
Solution | Class | 1 | Correct parameter list of axis. | ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Incorrect value [-] | ||||
| |||||
%3: | Corrected value [-] | ||||
| |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110043 | D/A-converter resolution is illegal (denominator). | ||||
| Description | The resolution for the digital/analog converter (denominator) is specified with zero. This value is illegal. | |||
Reaction | Class | 1 | Element is initialized by default value. | ||
Solution | Class | 1 | Correct parameter list of axis. | ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Incorrect value [-] | ||||
| |||||
%3: | Corrected value [-] | ||||
| |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110048 | SERCOS-drive: illegal type of protocol. | ||||
| Description | The SERCOS telegram type S-0-00015 was specified with an illegal value. | |||
Reaction | Class | 1 | Element is set to user defined telegram typ 7. | ||
Solution | Class | 1 | Correct parameter list of axis. | ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Incorrect value [-] | ||||
| |||||
%3: | Limit value [-] | ||||
| |||||
%4: | Corrected value [-] | ||||
| |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110051 | Illegal axis modifier for axis of type "TRANSLATOR". | ||||
| Description | The axis mode P-AXIS-00015 (bitcoded) is not set to linear for the given translatoric axis. | |||
Reaction | Class | 1 | The axis mode is set to linear. | ||
Solution | Class | 1 | Correction of axis parameter list | ||
Parameter | %1: | Logical axis number [-] | |||
P-AXIS-00016 | |||||
%2: | Incorrect value [-] | ||||
P-AXIS-00015 | |||||
%3: | Corrected value [-] | ||||
P-AXIS-00015 | |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110052 | Difference of modulo less than or equal to 0. | ||||
| Description | The difference between upper P-AXIS-00126 and lower modulo limit P-AXIS-00127 is smaller 0. The modulo range for rotatoric axis or spindels at least must be bigger 0.0001°. | |||
Reaction | Class | 1 | The upper and lower modulo limit is initialized by a default value. | ||
Solution | Class | 1 |
| ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Incorrect value [0.1 µm or 0,0001°] | ||||
P-AXIS-00126 - P-AXIS-00127 | |||||
%3: | Limit value [0.1 µm or 0,0001°] | ||||
| |||||
%4: | Corrected value [0.1 µm or 0,0001°] | ||||
| |||||
%5: | Corrected value [0.1 µm or 0,0001°] | ||||
| |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110053 | Axis modifier illegal. | ||||
| Description | For a rotatoric axis the axis mode P-AXIS-00015 (bitcoded) at least must be set to linear / optimized alignment mode / modulo. | |||
Reaction | Class | 1 | The axis mode is set to linear. | ||
Solution | Class | 1 | Correction of axis parameter list | ||
Parameter | %1: | Logical axis number [-] | |||
P-AXIS-00016 | |||||
%2: | Actual value [-] | ||||
P-AXIS-00015 | |||||
%3: | Corrected value [-] | ||||
P-AXIS-00015 | |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110054 | Axis position greater than software limit switch. | ||||
| Description | The given axis positon P-AXIS-00017 is above the positive software limit switch P-AXIS-00178. | |||
Reaction | Class | 1 |
| ||
Solution | Class | 6 | Correct element in axis paramter list. | ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Incorrect value [0.1 µm or 0,0001°] | ||||
| |||||
%3: | Limit value [0.1 µm or 0,0001°] | ||||
| |||||
%4: | Corrected value [0.1 µm or 0,0001°] | ||||
| |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110055 | Axis position smaller than software limit switch. | ||||
| Description | The given axis positon P-AXIS-00017 is below the negative software limit switch P-AXIS-00177. | |||
Reaction | Class | 1 |
| ||
Solution | Class | 6 | Correct element in axis paramter list. | ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Incorrect value [0.1 µm or 0,0001°] | ||||
| |||||
%3: | Limit value [0.1 µm or 0,0001°] | ||||
| |||||
%4: | Corrected value [0.1 µm or 0,0001°] | ||||
| |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110059 | Limit of velocity for stand still is above maximum velocity of axis. | ||||
| Description | The limit velocity P-AXIS-00216 for display of stand still is above the maximum axis velocity. | |||
Reaction | Class | 1 |
| ||
Solution | Class | 1 |
| ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Incorrect value [0.1 µm or 0,0001°] | ||||
| |||||
%3: | Limit value [0.1 µm or 0,0001°] | ||||
| |||||
%4: | Corrected value [0.1 µm or 0,0001°] | ||||
| |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110060 | Unknown drive type. | ||||
| Description | The given axis type P-AXIS-00018 is unknown. Following types are valid: 1 – linear axis 2 – rotatory axis 4 – spindle | |||
Reaction | Class | 3 | Stop of actual job. | ||
Solution | Class | 7 | Set correct axis type in parameter list. | ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Incorrect value [-] | ||||
| |||||
Error type | - | ||||
| |||||
110061 | Turning rate at modulo error less than 0. | ||||
| Description | The number of modulo revolutions P-AXIS-00125 is zero. For a active modulo compensation P-AXIS-00120 the revolutions must be bigger zero. | |||
Reaction | Class | 1 | Initialization of Modulorevolutions with default value. | ||
Solution | Class | 1 | Correct value in paramter list. | ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Actual value [-] | ||||
| |||||
%3: | Limit value [-] | ||||
| |||||
%4: | Corrected value [-] | ||||
| |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110062 | Axis number may not be changed after having started the system. | ||||
| Description | The parameter P-AXIS-00016 for straightforward identification of axis in system cannot be changed while CNC kernel is running. The new logical axis number is not transfered, the previous active logical axis number remains valid. | |||
Reaction | Class | 1 | None. | ||
Solution | Class | 1 | Only change logical axis number P-AXIS-00016 in configuration mode or if CNC kernel does not run respectively. | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number P-AXIS-00016 of affected axis. | |||||
%2: | Actual value [-] | ||||
Current value of P-AXIS-00016. | |||||
%3: | Corrected value [-] | ||||
Corrected value of P-AXIS-00016. | |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110063 | Drive type may not be changed after having started the system. | ||||
| Description | The parameter P-AXIS-00020 for drive type of axis cannot be changed while CNC kernel is running. The new drive type is not transfered, the previous active drive type remains valid. | |||
Reaction | Class | 1 | None. | ||
Solution | Class | 1 | Only change drive type P-AXIS-00020 in configuration mode or if CNC kernel does not run respectively. | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number P-AXIS-00016 of affected axis. | |||||
%2: | Actual value [-] | ||||
Current value of P-AXIS-00020. | |||||
%3: | Corrected value [-] | ||||
Corrected value of P-AXIS-00020. | |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110064 | All axis have to have different axis numbers. | ||||
| Description | For two axes in system the same logical axis number setting P-AXIS-00016 is used. This is not allowed. The data transfer for the second axis with the same logical axis number is rejected. | |||
Reaction | Class | 1 | None. | ||
Solution | Class | 1 | Use for all the axes in system different logical axis numbers P-AXIS-00016. | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number P-AXIS-00016 of affected axis. | |||||
%2: | Actual value [-] | ||||
Current logical axis number. | |||||
%3: | Corrected value [-] | ||||
Corrected logical axis number P-AXIS-00016. | |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110065 | Unknown drive type. | ||||
| Description | The given drive type is not known. | |||
Reaction | Class | 3 |
| ||
Solution | Class | 7 | Check P-AXIS-00020 | ||
Parameter | %1: | Logical axis number [-] | |||
s. P-AXIS-00016 | |||||
%2: | Incorrect value [-] | ||||
s. P-AXIS-00020 | |||||
Error type | - | ||||
| |||||
110066 | Missing gear with specified number. | ||||
| Description | Try to select an unknown gear step, e.g. by G112 X<gear step>. | |||
Reaction | Class | 3 |
| ||
Solution | Class | 7 |
| ||
Parameter | %1: | Actual value [-] | |||
Gear Stepp | |||||
%2: | Logical axis number [-] | ||||
| |||||
%3: | Upper limit value [-] | ||||
Maximum number of gears | |||||
Error type | - | ||||
| |||||
110067 | Axis data for gear step incomplete. | ||||
| Description | The parameterlist of an axis is initialized incomplete. This can just happen, if the parameterset of an axis is passed in binary form to the CNC. | |||
Reaction | Class | 3 |
| ||
Solution | Class | 7 |
| ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Incorrect value [-] | ||||
incorrect bit | |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110068 | Hardware independent axis dates for position controller incomplete. | ||||
| Description | The parameterlist of an axis is initialized incomplete. This can just happen, if the parameterset of an axis is passed in binary form to the CNC. | |||
Reaction | Class | 3 |
| ||
Solution | Class | 7 |
| ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Incorrect value [-] | ||||
incorrect bit | |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110069 | Hardware dependent axis dates for position controller incomplete. | ||||
| Description | The parameterlist of an axis is initialized incomplete. This can just happen, if the parameterset of an axis is passed in binary form to the CNC. | |||
Reaction | Class | 3 |
| ||
Solution | Class | 7 |
| ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Incorrect value [-] | ||||
incorrect bit | |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110070 | Machine dates for path controller incomplete. | ||||
| Description | The parameterlist of an axis is initialized incomplete. This can just happen, if the parameterset of an axis is passed in binary form to the CNC. | |||
Reaction | Class | 3 |
| ||
Solution | Class | 7 |
| ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Incorrect value [-] | ||||
incorrect bit | |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110071 | Axis dates for acceleration and velocity precontrol incomplete. | ||||
| Description | The parameterlist of an axis is initialized incomplete. This can just happen, if the parameterset of an axis is passed in binary form to the CNC. | |||
Reaction | Class | 3 |
| ||
Solution | Class | 7 |
| ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Incorrect value [-] | ||||
incorrect bit | |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110073 | Parameters for digital drive interface incomplete. | ||||
| Description | The parameterlist of an axis is initialized incomplete. This can just happen, if the parameterset of an axis is passed in binary form to the CNC. | |||
Reaction | Class | 3 |
| ||
Solution | Class | 7 |
| ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Incorrect value [-] | ||||
incorrect bit | |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110074 | Parameters for manual operation mode incomplete. | ||||
| Description | The parameterlist of an axis is initialized incomplete. This can just happen, if the parameterset of an axis is passed in binary form to the CNC. | |||
Reaction | Class | 3 |
| ||
Solution | Class | 7 |
| ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Incorrect value [-] | ||||
incorrect bit | |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110075 | Parameters for position controller and interpolator incomplete. | ||||
| Description | The parameterlist of an axis is initialized incomplete. This can just happen, if the parameterset of an axis is passed in binary form to the CNC. | |||
Reaction | Class | 3 |
| ||
Solution | Class | 7 |
| ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Incorrect value [-] | ||||
incorrect bit | |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110076 | Axis number is 0. | ||||
| Description | The logical number of the axis parameter list must not be zero. | |||
Reaction | Class | 3 |
| ||
Solution | Class | 7 |
| ||
Parameter | %1: | Incorrect value [-] | |||
| |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110077 | Gear switch position exceeds positive software limit switch. | ||||
| Description | The gear switch position P-AXIS-00078 exceeds the positive software limit switch P-AXIS-00178. | |||
Reaction | Class | 1 | The gear switch position is set to the middle of both software limit switches. | ||
Solution | Class | 1 | Correct of value in parameter list. | ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Actual value [-] | ||||
| |||||
%3: | Limit value [-] | ||||
| |||||
%4: | Corrected value [-] | ||||
| |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110078 | Gear switch position exceeds negative software limit switch. | ||||
| Description | The gear switch position P-AXIS-00078 is below the negative software limit switch P-AXIS-00177. | |||
Reaction | Class | 1 | The gear switch position is set to the middle of both software limit switches. | ||
Solution | Class | 1 | Correct of value in parameter list. | ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Actual value [-] | ||||
| |||||
%3: | Limit value [-] | ||||
| |||||
%4: | Corrected value [-] | ||||
| |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110079 | maximum speed is not allowed to be 0. | ||||
| Description | The maximum velocityof the axis is given by 0. The maximum velocity must be greater 0. | |||
Reaction | Class | 1 | Initialization of parameter with default value. | ||
Solution | Class | 1 | Correct value in paramter list. | ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Incorrect value [1µm/sec or 0,001°/sec] | ||||
| |||||
%3: | Corrected value [1µm/sec or 0,001°/sec] | ||||
| |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110080 | maximum speed is greater than maximum speed defined in "spezif.inc". | ||||
| Description | The maximum velocity P-AXIS-00212 of the axis exceeds the maximum velocity of the CNC. | |||
Reaction | Class | 1 | Initialization of parameter with maximum velocity of CNC. | ||
Solution | Class | 1 | Correct value in paramter list. | ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Actual value [1µm/sec or 0,001°/sec] | ||||
| |||||
%3: | Limit value [1µm/sec or 0,001°/sec] | ||||
| |||||
%4: | Corrected value [1µm/sec or 0,001°/sec] | ||||
| |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110081 | maximum acceleration is not allowed to be 0. | ||||
| Description | The maximum acceleration P-AXIS-00008 of the axis is given by 0. The maximum acceleration must be greater 0. | |||
Reaction | Class | 1 | Initialization of parameter with minimum acceleration of CNC value. | ||
Solution | Class | 1 | Correct value in paramter list. | ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Actual value [1µm/sec or 0,001°/sec] | ||||
| |||||
%3: | Corrected value [1µm/sec or 0,001°/sec] | ||||
| |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110082 | maximum acceleration is greater than maximum value defined in "spezif.inc". | ||||
| Description | The maximum acceleration P-AXIS-00008 of the axis exceeds the maximum acceleration of the CNC. | |||
Reaction | Class | 1 | Initialization of parameter with default acceleration of CNC value. | ||
Solution | Class | 1 | Correct value in paramter list. | ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Actual value [1mm/sec^2 or 1°/sec^2] | ||||
| |||||
%3: | Limit value [1mm/sec^2 or 1°/sec^2] | ||||
| |||||
%4: | Corrected value [1mm/sec^2 or 1°/sec^2] | ||||
| |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110083 | Illegal SLOPE time. | ||||
| Description | The value for the slope time P-AXIS-00201 is not valid. | |||
Reaction | Class | 1 | Output of warning. The value for P-AXIS-00201 is set to the limit value. | ||
Solution | Class | 1 | Choose value for P-AXIS-00201 bigger than the limit value. | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number P-AXIS-00016 of affected axis. | |||||
%2: | Actual value [1 µsec] | ||||
Actual value of P-AXIS-00201. | |||||
%3: | Limit value [1 µsec] | ||||
Limit value of P-AXIS-00201. | |||||
%4: | Corrected value [1 µsec] | ||||
Corrected value of P-AXIS-00201. | |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110084 | Rapid feed rate is not allowed to be 0. | ||||
| Description | The rapid velocity P-AXIS-00209 of the axis is given by 0. The maximum velocity must be greater 0. | |||
Reaction | Class | 1 | Initialization of parameter with default value. | ||
Solution | Class | 1 | Correct value in paramter list. | ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Actual value [1µm/sec or 0,001°/sec] | ||||
| |||||
%3: | Corrected value [1µm/sec or 0,001°/sec] | ||||
| |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110085 | Rapid feed rate is greater than maximum feed rate. | ||||
| Description | The rapid feedrate P-AXIS-00209 lies above the maximum velocity of the axis. | |||
Reaction | Class | 1 | Initialization of parameter with maximum velocity of axis. | ||
Solution | Class | 1 | Correct value in paramter list. | ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Actual value [1µm/sec or 0,001°/sec] | ||||
| |||||
%3: | Limit value [1µm/sec or 0,001°/sec] | ||||
| |||||
%4: | Corrected value [1µm/sec or 0,001°/sec] | ||||
| |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110086 | Implausible contour resolution. | ||||
| Description | The denominator of the resolution P-AXIS-00233 of the measurement system is given with zero. This value must be initialized unequal zero. The resolution of the measurement system is given as factor between P-AXIS-00234 / P-AXIS-00233 in increments per 0,1 µm or per 0,0001°. | |||
Reaction | Class | 1 | Initialization of denominator with default value | ||
Solution | Class | 1 | Correct value in paramter list | ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Actual value [-] | ||||
| |||||
%3: | Corrected value [-] | ||||
| |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110087 | Implausible controller window. | ||||
| Description | The size of the window P-AXIS-00236 was given with zero. The window is used to display the “in position” state information of an axis, if the position lag is smaller than the specified window. | |||
Reaction | Class | 1 | Initialization of window with default value | ||
Solution | Class | 1 | Correct value in parameter list | ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Actual value [-] | ||||
| |||||
%3: | Corrected value [-] | ||||
| |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110088 | Acceleration step 1 is 0. | ||||
| Description | The acceleration P-AXIS-00011 of the first Step of the linear slope (not jerk limited) is given with zero. The acceleration must be bigger 0. | |||
Reaction | Class | 1 | Initialization of acceleration with default value | ||
Solution | Class | 1 | Correct value in parameter list | ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Actual value [1mm/sec^2 or 1°/sec^2] | ||||
| |||||
%3: | Corrected value [1mm/sec^2 or 1°/sec^2] | ||||
| |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110089 | Acceleration step 1 is greater than maximum acceleration. | ||||
| Description | The acceleration P-AXIS-00011 of the first Step of the linear slope (not jerk limited) is bigger than the maximum acceleration P-AXIS-00008 of the axis. | |||
Reaction | Class | 1 | Limitation of acceleration with maximum value | ||
Solution | Class | 1 | Correct value in parameter list | ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Actual value [1mm/sec^2 or 1°/sec^2] | ||||
| |||||
%3: | Upper limit value [1mm/sec^2 or 1°/sec^2] | ||||
| |||||
%4: | Corrected value [1mm/sec^2 or 1°/sec^2] | ||||
| |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110090 | Acceleration step 2 is 0. | ||||
| Description | The acceleration P-AXIS-00012 of the second Step of the linear slope (not jerk limited) is given with zero. The acceleration must be bigger 0. | |||
Reaction | Class | 1 | Initialization of acceleration with default value | ||
Solution | Class | 1 | Correct value in parameter list | ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Actual value [1mm/sec^2 or 1°/sec^2] | ||||
| |||||
%3: | Corrected value [1mm/sec^2 or 1°/sec^2] | ||||
| |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110091 | Acceleration step 2 is greater than maximum acceleration. | ||||
| Description | The acceleration P-AXIS-00012 of the second Step of the linear slope (not jerk limited) is bigger than the maximum acceleration P-AXIS-00008 of the axis. | |||
Reaction | Class | 1 | Limitation of acceleration with maximum value | ||
Solution | Class | 1 | Correct value in parameter list | ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Actual value [1mm/sec^2 or 1°/sec^2] | ||||
| |||||
%3: | Upper limit value [1mm/sec^2 or 1°/sec^2] | ||||
| |||||
%4: | Corrected value [1mm/sec^2 or 1°/sec^2] | ||||
| |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110092 | Acceleration limit step 1 is 0. | ||||
| Description | The current limit acceleration P-AXIS-00005 of the first Step of the linear slope (not jerk limited) is given with zero. The acceleration must be bigger 0. | |||
Reaction | Class | 1 | Initialization of acceleration with default value | ||
Solution | Class | 1 | Correct value in parameter list | ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Actual value [1mm/sec^2 or 1°/sec^2] | ||||
| |||||
%3: | Corrected value [1mm/sec^2 or 1°/sec^2] | ||||
| |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110093 | Acceleration limit step 1 is greater than maximum acceleration. | ||||
| Description | The current limit acceleration P-AXIS-00005 of the first Step of the linear slope (not jerk limited) is bigger than the maximum acceleration P-AXIS-00008 of the axis. | |||
Reaction | Class | 1 | Limitation of acceleration with maximum value | ||
Solution | Class | 1 | Correct value in parameter list | ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Actual value [1mm/sec^2 or 1°/sec^2] | ||||
| |||||
%3: | Upper limit value [1mm/sec^2 or 1°/sec^2] | ||||
| |||||
%4: | Corrected value [1mm/sec^2 or 1°/sec^2] | ||||
| |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110094 | Acceleration limit step 2 is 0. | ||||
| Description | The current limit acceleration P-AXIS-00006 of the second step of the linear slope (not jerk limited) is given with zero. The acceleration must be bigger 0. | |||
Reaction | Class | 1 | Initialization of acceleration with default value | ||
Solution | Class | 1 | Correct value in parameter list | ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Actual value [1mm/sec^2 or 1°/sec^2] | ||||
| |||||
%3: | Corrected value [1mm/sec^2 or 1°/sec^2] | ||||
| |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110095 | Acceleration limit step 2 is greater than maximum acceleration. | ||||
| Description | The current limit acceleration P-AXIS-00006 of the second step of the linear slope (not jerk limited) is bigger than the maximum acceleration P-AXIS-00008 of the axis. | |||
Reaction | Class | 1 | Limitation of acceleration with maximum value | ||
Solution | Class | 1 | Correct value in parameter list | ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Actual value [1mm/sec^2 or 1°/sec^2] | ||||
| |||||
%3: | Upper limit value [1mm/sec^2 or 1°/sec^2] | ||||
| |||||
%4: | Corrected value [1mm/sec^2 or 1°/sec^2] | ||||
| |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110096 | Switching feed rate is 0. | ||||
| Description | The velocity limit P-AXIS-00221 for change between acceleration of the first and second step of the linear slope (not jerk limited) is given with 0. The value must be bigger 0. | |||
Reaction | Class | 1 | Limitation of acceleration with maximum value | ||
Solution | Class | 1 | Correct value in parameter list | ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Actual value [1µm/sec or 0,001°/sec] | ||||
| |||||
%3: | Corrected value [1µm/sec or 0,001°/sec] | ||||
| |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110097 | Switching feed rate is greater than maximum feed rate. | ||||
| Description | The velocity limit P-AXIS-00221 for change between acceleration of the first and second step of the linear slope (not jerk limited) is bigger than the maximum acceleration P-AXIS-00008 of the axis. | |||
Reaction | Class | 1 | Limitation of acceleration with maximum value | ||
Solution | Class | 1 | Correct value in parameter list | ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Actual value [1µm/sec or 0,001°/sec] | ||||
| |||||
%3: | Upper limit value [1µm/sec or 0,001°/sec] | ||||
| |||||
%4: | Corrected value [1µm/sec or 0,001°/sec] | ||||
| |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110098 | Switching feed rate is 0. | ||||
| Description | The velocity limit P-AXIS-00211 for change between current limit acceleration of the first and second step of the linear slope (not jerk limited) is given with 0. The value must be bigger 0. | |||
Reaction | Class | 1 | Limitation of acceleration with maximum value | ||
Solution | Class | 1 | Correct value in parameter list | ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Actual value [1µm/sec or 0,001°/sec] | ||||
| |||||
%3: | Corrected value [1µm/sec or 0,001°/sec] | ||||
| |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110099 | Switching feed rate is greater than maximum feed rate. | ||||
| Description | The velocity limit P-AXIS-00211 for change between current limit acceleration of the first and second step of the linear slope (not jerk limited) is bigger than the maximum acceleration P-AXIS-00008 of the axis. | |||
Reaction | Class | 1 | Limitation of velocity with maximum value | ||
Solution | Class | 1 | Correct value in parameter list | ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Actual value [1µm/sec or 0,001°/sec] | ||||
| |||||
%3: | Upper limit value [1µm/sec or 0,001°/sec] | ||||
| |||||
%4: | Corrected value [1µm/sec or 0,001°/sec] | ||||
| |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110100 | Acceleration is 0. | ||||
| Description | The acceleration P-AXIS-00001 of the non linear slope (jerk limited) is given with zero. The acceleration must be bigger 0. | |||
Reaction | Class | 1 | Initialization of acceleration with default value | ||
Solution | Class | 1 | Correct value in parameter list | ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Actual value [1mm/sec^2 or 1°/sec^2] | ||||
| |||||
%3: | Corrected value [1mm/sec^2 or 1°/sec^2] | ||||
| |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110101 | Acceleration is greater than maximum acceleration. | ||||
| Description | The acceleration P-AXIS-00001 of the non linear slope (jerk limited) is bigger than the maximum acceleration P-AXIS-00008 of the axis. | |||
Reaction | Class | 1 | Limitation of acceleration with maximum value | ||
Solution | Class | 1 | Correct value in parameter list | ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Actual value [1mm/sec^2 or 1°/sec^2] | ||||
| |||||
%3: | Upper limit value [1mm/sec^2 or 1°/sec^2] | ||||
| |||||
%4: | Corrected value [1mm/sec^2 or 1°/sec^2] | ||||
| |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110102 | Deceleration is 0. | ||||
| Description | The deceleration P-AXIS-00002 of the non linear slope (jerk limited) is given with zero. The acceleration must be bigger 0. | |||
Reaction | Class | 1 | Initialization of acceleration with default value | ||
Solution | Class | 1 | Correct value in parameter list | ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Actual value [1mm/sec^2 or 1°/sec^2] | ||||
| |||||
%3: | Corrected value [1mm/sec^2 or 1°/sec^2] | ||||
| |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110103 | Deceleration is greater than maximum value. | ||||
| Description | The deceleration P-AXIS-00002 of the non linear slope (jerk limited) is bigger than the maximum acceleration P-AXIS-00008 of the axis. | |||
Reaction | Class | 1 | Limitation of acceleration with maximum value | ||
Solution | Class | 1 | Correct value in parameter list | ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Actual value [1mm/sec^2 or 1°/sec^2] | ||||
| |||||
%3: | Upper limit value [1mm/sec^2 or 1°/sec^2] | ||||
| |||||
%4: | Corrected value [1mm/sec^2 or 1°/sec^2] | ||||
| |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110104 | SLOPE time for increasing acceleration is too small. | ||||
| Description | The (time for reaching the maximum acceleration P-AXIS-00196 (ramp time) of jerk limited slope is smaller than the minimal ramp time P-AXIS-00201 of the axis. | |||
Reaction | Class | 1 | Limitation of ramp time with minimal value | ||
Solution | Class | 1 | Correct value in parameter list | ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Actual value [1 µsec] | ||||
| |||||
%3: | Lower limit value [1 µsec] | ||||
| |||||
%4: | Corrected value [1 µsec] | ||||
| |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110105 | SLOPE time for decreasing acceleration is too small. | ||||
| Description | The time for decreasing the maximum acceleration P-AXIS-00196 to zero (ramp time) of jerk limited slope is smaller than the minimal ramp time P-AXIS-00201 of the axis. | |||
Reaction | Class | 1 | Limitation of ramp time with minimal value | ||
Solution | Class | 1 | Correct value in parameter list | ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Actual value [1 µsec] | ||||
| |||||
%3: | Lower limit value [1 µsec] | ||||
| |||||
%4: | Corrected value [1 µsec] | ||||
| |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
|
|
| |||
110106 | SLOPE time for increasing deceleration is too small. | ||||
| Description | The time for reaching the maximum deceleration P-AXIS-00198 (ramp time) of jerk limited slope is smaller than the minimal ramp time P-AXIS-00201 of the axis. | |||
Reaction | Class | 1 | Limitation of ramp time with minimal value | ||
Solution | Class | 1 | Correct value in parameter list | ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Actual value [1 µsec] | ||||
| |||||
%3: | Lower limit value [1 µsec] | ||||
| |||||
%4: | Corrected value [1 µsec] | ||||
| |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110107 | SLOPE time for decreasing deceleration is too small. | ||||
| Description | The time for decreasing the maximum deceleration P-AXIS-00197 to zero (ramp time) of jerk limited slope is smaller than the minimal ramp time P-AXIS-00201 of the axis. | |||
Reaction | Class | 1 | Limitation of ramp time with minimal value | ||
Solution | Class | 1 | Correct value in parameter list | ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Actual value [1 µsec] | ||||
| |||||
%3: | Lower limit value [1 µsec] | ||||
| |||||
%4: | Corrected value [1 µsec] | ||||
| |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110110 | Difference of software limit switches is 0. | ||||
| Description | The movement range between the software limit switches is zero. | |||
Reaction | Class | 1 | The the software limit switches are set to default values | ||
Solution | Class | 1 | Correct value in parameter list. | ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Actual value [-] | ||||
| |||||
%3: | Actual value [-] | ||||
| |||||
%4: | Incorrect value [-] | ||||
Actual range | |||||
%5: | Corrected value [-] | ||||
Corrected range | |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110111 | Speed override is 0. | ||||
| Description | The parameter P-AXIS-00109 for maximum axis specific velocity override is smaller than permissible minimum value. The parameter value is set to default minimum value. | |||
Reaction | Class | 1 | None. | ||
Solution | Class | 1 | Parameter setting of P-AXIS-00109 bigger than or equal to lower limit value. | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number P-AXIS-00016 of affected axis. | |||||
%2: | Actual value [-] | ||||
Current permille value P-AXIS-00109. | |||||
%3: | Corrected value [-] | ||||
Corrected permille value P-AXIS-00109. | |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110112 | Speed override exceeds limit. | ||||
| Description | The parameter P-AXIS-00109 for maximum axis specific velocity override is smaller than permissible minimum value. The parameter value is set to default maximum value. | |||
Reaction | Class | 1 | None. | ||
Solution | Class | 1 | Parameter setting of P-AXIS-00109 smaller than or equal to upper limit value. | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number P-AXIS-00016 of affected axis. | |||||
%2: | Actual value [-] | ||||
Current parameter value P-AXIS-00109. | |||||
%3: | Limit value [-] | ||||
Upper parameter limit value. | |||||
%4: | Corrected value [-] | ||||
Corrected parameter value P-AXIS-00109. | |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110113 | Measureing feed rate is 0. | ||||
| Description | The parameter P-AXIS-00215 for feed of measurement movement is smaller than minimum permissible value. The parameter value is set to default value. | |||
Reaction | Class | 1 | None. | ||
Solution | Class | 1 | Setting of feed for measurement bigger than minimum value. | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number P-AXIS-00016 of affected axis. | |||||
%2: | Actual value [1µm/sec or 0,001°/sec] | ||||
Current feed for measurement movement P-AXIS-00215. | |||||
%3: | Corrected value [1µm/sec or 0,001°/sec] | ||||
Corrected feed for measurement movement P-AXIS-00215. | |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110114 | Measureing feed rate exceeds limit. | ||||
| Description | The parameter P-AXIS-00215 for feed of measurement movement is bigger than maximum permissible value. The parameter value is set to default value. | |||
Reaction | Class | 1 | None. | ||
Solution | Class | 1 | Setting of feed for measurement smaller than maximum value. | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number P-AXIS-00016 of affected axis. | |||||
%2: | Actual value [1µm/sec or 0,001°/sec] | ||||
Current active feed for measurement P-AXIS-00215. | |||||
%3: | Limit value [1µm/sec or 0,001°/sec] | ||||
Upper limit for measurement feed. | |||||
%4: | Corrected value [1µm/sec or 0,001°/sec] | ||||
Corrected feed for measurement P-AXIS-00215. | |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110115 | Number of gear step is 0. | ||||
| Description | The parameter P-AXIS-00079 for active gear step after startup of CNC is set to zero. The gear step is set to default gear step. | |||
Reaction | Class | 1 | None. | ||
Solution | Class | 1 | Gear step bigger than 0. | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number P-AXIS-00016 of affected axis. | |||||
%2: | Actual value [-] | ||||
Current value for gear step P-AXIS-00079. | |||||
%3: | Corrected value [-] | ||||
Corrected gear step P-AXIS-00079. | |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110116 | Illegal measureing method. Only one method may be selected. | ||||
| Description |
| |||
Reaction | Class | 1 |
| ||
Solution | Class | 1 |
| ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Actual value [-] | ||||
| |||||
%3: | Actual value [-] | ||||
| |||||
%4: | Corrected value [-] | ||||
| |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110117 | Measuring via SERCOS-protocol only for kenngr.antr_typ equal to ANTR_TYP_SERCOS. | ||||
| Description | Invalid parameter setting for P-AXIS-00116 for SERCOS -measurement is used. The parameter P-AXIS-00116 is set to default value. | |||
Reaction | Class | 1 | None. | ||
Solution | Class | 1 | Only use parameter P-AXIS-00116 if drive type P-AXIS-00020 setting is SERCOS drive. | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number of affected axis P-AXIS-00016. | |||||
%2: | Actual value [-] | ||||
Current value of P-AXIS-00020 | |||||
%3: | Drive type [-] | ||||
Corrected value of P-AXIS-00116. | |||||
%4: | Corrected value [-] | ||||
| |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110118 | At least one measureing method has to be defined. | ||||
| Description | If one axis is marked as measurement axis P-AXIS-00118 also the measurement method has to be parameterized. The parameter P-AXIS-00117 is set to value 1. | |||
Reaction | Class | 1 | None. | ||
Solution | Class | 1 | Depending on drive type P-AXIS-00020 at least one measurement method has to be parameterized or P-AXIS-00118 has to be set to zero. | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number of affected axis P-AXIS-00016. | |||||
%2: | Corrected value [-] | ||||
Current drive type P-AXIS-00020. | |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110119 | Assignment of 0 to parameter is not permitted. | ||||
| Description | The parameter P-AXIS-00023 for control of display function in position controller is set to invalid value. The parameter P-AXIS-00023 is set to lower limit value. | |||
Reaction | Class | 1 | None. | ||
Solution | Class | 1 | Only use parameter setting of P-AXIS-00023 bigger than 0. | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number of affected axis P-AXIS-00016. | |||||
%2: | Actual value [-] | ||||
Current value P-AXIS-00023. | |||||
%3: | Corrected value [-] | ||||
Corrected value P-AXIS-00023. | |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110120 | Parameter value exceeds limit. | ||||
| Description | The parameter P-AXIS-00023 for control of display function in position controller is set to invalid high value. The parameter P-AXIS-00023 is set to upper limit value. | |||
Reaction | Class | 1 | None. | ||
Solution | Class | 1 | Only use parameter setting of P-AXIS-00023 smaller than upper limit value. | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number of affected axis P-AXIS-00016. | |||||
%2: | Actual value [-] | ||||
Current value P-AXIS-00023. | |||||
%3: | Limit value [-] | ||||
Upper limit value. | |||||
%4: | Corrected value [-] | ||||
Corrected value P-AXIS-00023. | |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110121 | Illegal modifier of precontrol. | ||||
| Description | The given kind of the feed forward control is incorrect. You just can specify the values (see P-AXIS-00223) described in the description. | |||
Reaction | Class | 1 |
| ||
Solution | Class | 1 |
| ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Actual value [-] | ||||
Bit coded variable P-AXIS-00223 | |||||
%3: | Limit value [-] | ||||
| |||||
%4: | Corrected value [-] | ||||
| |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110122 | Numerator of velocity feed forward factor is 0. | ||||
| Description | The numerator of the factor for normalization of the velocity feed forward control P-AXIS-00228 was given with zero. | |||
Reaction | Class | 1 |
| ||
Solution | Class | 1 |
| ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Actual value [-] | ||||
| |||||
%3: | Corrected value [-] | ||||
| |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
Numerator is initialized with default value. | |||||
110123 | Denominator of velocity feed forward factor is 0. | ||||
| Description | The denominator of the factor for normalization of the velocity feed forward control P-AXIS-00226 was given with zero. | |||
Reaction | Class | 1 |
| ||
Solution | Class | 1 |
| ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Actual value [-] | ||||
| |||||
%3: | Corrected value [-] | ||||
| |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
Denominator is initialized with defaultvalue. | |||||
110124 | Hand wheel resolution is smaller than lower limit. | ||||
| Description | The axis specific resolution parameter with active manual mode P-AXIS-00025 has to set to value > 0. | |||
Reaction | Class | 1 | None. | ||
Solution | Class | 1 | Only use manual mode resolution P-AXIS-00025 > 0. | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number P-AXIS-00016 of affected axis. | |||||
%2: | Actual value [-] | ||||
Current resolution P-AXIS-00025. | |||||
%3: | Corrected value [-] | ||||
Corrected resolution P-AXIS-00025. | |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110125 | Maximum feed rate for manual mode is not allowed to be 0. | ||||
| Description | The maximum velocity P-AXIS-00213 with active manual mode operation is zero. The maximum velocity is set to default value. | |||
Reaction | Class | 1 | None. | ||
Solution | Class | 1 | Maximum velocity setting for manual mode P-AXIS-00213 bigger than 0. | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number P-AXIS-00016 of affected axis. | |||||
%2: | Actual value [1µm/sec or 0,001°/sec] | ||||
Current maximum velocity P-AXIS-00213. | |||||
%3: | Corrected value [1µm/sec or 0,001°/sec] | ||||
Corrected maximum velocity P-AXIS-00213. | |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110126 | Maximum feed rate for manual mode exceeds limit. | ||||
| Description | The maximum velocity P-AXIS-00213 with active manual mode operation excceds upper limit value. The maximum velocity is set to default value. | |||
Reaction | Class | 1 | None. | ||
Solution | Class | 1 | Maximum velocity setting for manual mode P-AXIS-00213 smaller than P-AXIS-00212. | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number P-AXIS-00016 of affected axis. | |||||
%2: | Actual value [1µm/sec or 0,001°/sec] | ||||
Current maximum velocity P-AXIS-00213. | |||||
%3: | Limit value [1µm/sec or 0,001°/sec] | ||||
Upper limit value of velocity. | |||||
%4: | Corrected value [1µm/sec or 0,001°/sec] | ||||
Corrected maximum velocity P-AXIS-00213 | |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110127 | Maximum feed rate for manual mode is not allowed to be 0. | ||||
| Description | The acceleration P-AXIS-00009 for active manual mode operation is smaller than the minimum permissible value of the axis. The acceleration is set to minimum permissible value. | |||
Reaction | Class | 1 | None. | ||
Solution | Class | 1 | Use acceleration setting bigger than minimum value. | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number P-AXIS-00016 of affected axis. | |||||
%2: | Actual value [1mm/sec^2 or 1°/sec^2] | ||||
Current setting of P-AXIS-00009. | |||||
%3: | Corrected value [1mm/sec^2 or 1°/sec^2] | ||||
Corrected setting of P-AXIS-00009. | |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110128 | Maximum feed rate for manual mode exceeds limit. | ||||
| Description | The acceleration P-AXIS-00009 for active manual mode operation is bigger than the maximum acceleration P-AXIS-00008 of the axis. The acceleration is limited to P-AXIS-00008. | |||
Reaction | Class | 1 | None. | ||
Solution | Class | 1 | Use acceleration setting smaller than P-AXIS-00008 | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number P-AXIS-00016 of affected axis. | |||||
%2: | Actual value [1mm/sec^2 or 1°/sec^2] | ||||
Current setting of P-AXIS-00009. | |||||
%3: | Upper limit value [1mm/sec^2 or 1°/sec^2] | ||||
Upper limit value for acceleration P-AXIS-00008. | |||||
%4: | Corrected value [1mm/sec^2 or 1°/sec^2] | ||||
Limited acceleration P-AXIS-00009. | |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110129 | Percentage for manual mode feed rate in manual mode too small. | ||||
| Description | While active manual mode with parallel interpolation (G201) the axis dynamic values are distributed with percentage value between path interpolation and axis specific manual mode interpolator. The percentage share value of maximum velocity P-AXIS-00212 for manual mode interpolator is made via P-AXIS-00083. The percentage share value of maximum velocity for manual mode is set to lower limit value. | |||
Reaction | Class | 1 | None | ||
Solution | Class | 1 | Percentage share value setting of P-AXIS-00083 bigger than lower limit value. | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number P-AXIS-00016 of affected axis. | |||||
%2: | Actual value [0,1%] | ||||
Current percentage share value P-AXIS-00083. | |||||
%3: | Lower limit value [0,1%] | ||||
Lower limit value for percentage share value. | |||||
%4: | Corrected value [0,1%] | ||||
Corrected percentage share value P-AXIS-00083. | |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110130 | Percentage for manual mode feed rate in manual mode too big. | ||||
| Description | While active manual mode with parallel interpolation (G201) the axis dynamic values are distributed with percentage value between path interpolation and axis specific manual mode interpolator. The percentage share value of maximum velocity P-AXIS-00212 for manual mode interpolator is made via P-AXIS-00083. The percentage share value of maximum velocity for manual mode is set to default upper limit value. | |||
Reaction | Class | 1 | None. | ||
Solution | Class | 1 | Percentage share value setting of P-AXIS-00083 smaller than upper limit value. | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number P-AXIS-00016 of affected axis. | |||||
%2: | Actual value [0,1%] | ||||
Current percentage share value P-AXIS-00083. | |||||
%3: | Upper limit value [0,1%] | ||||
Upper limit value for percentage share value. | |||||
%4: | Corrected value [0,1%] | ||||
Corrected percentage share value P-AXIS-00083. | |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110131 | Percentage for manual mode acceleration in manual mode too small. | ||||
| Description | While active manual mode with parallel interpolation (G201) the axis dynamic values are distributed with percentage value between path interpolation and axis specific manual mode interpolator. The percentage share value of maximum acceleration P-AXIS-00008 for manual mode interpolator is made via P-AXIS-00082. The percentage share value of maximum velocity for manual mode is set to lower limit value. | |||
Reaction | Class | 1 | None. | ||
Solution | Class | 1 | Percentage share value setting of P-AXIS-00082 bigger than lower limit value. | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number P-AXIS-00016 of affected axis. | |||||
%2: | Actual value [0,1%] | ||||
Current percentage share value P-AXIS-00082. | |||||
%3: | Lower limit value [0,1%] | ||||
Lower limit value for percentage share value. | |||||
%4: | Corrected value [0,1%] | ||||
Corrected percentage share value P-AXIS-00082. | |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110132 | Percentage for manual mode acceleration in manual mode too big. | ||||
| Description | While active manual mode with parallel interpolation (G201) the axis dynamic values are distributed with percentage value between path interpolation and axis specific manual mode interpolator. The percentage share value of maximum acceleration P-AXIS-00008 for manual mode interpolator is made via P-AXIS-00082. The percentage share value of maximum velocity for manual mode is set to upper limit value. | |||
Reaction | Class | 1 | None. | ||
Solution | Class | 1 | Percentage share value setting of P-AXIS-00082 smaller than upper limit value. | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number P-AXIS-00016 of affected axis. | |||||
%2: | Actual value [0,1%] | ||||
Current percentage share value P-AXIS-00082. | |||||
%3: | Upper limit value [0,1%] | ||||
Upper limit value for percentage share value. | |||||
%4: | Corrected value [0,1%] | ||||
Corrected percentage share value P-AXIS-00082. | |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110133 | Percentage for interpolation feed rate in manual mode too small. | ||||
| Description | While active manual mode with parallel interpolation (G201) the axis dynamic values are distributed with percentage value between path interpolation and axis specific manual mode interpolator. The percentage share value of maximum velocity P-AXIS-00212 for path interpolator is made via P-AXIS-00095. The percentage share value of maximum velocity for manual mode is set to lower limit value. | |||
Reaction | Class | 1 | None. | ||
Solution | Class | 1 | Percentage share value setting of P-AXIS-00095 bigger than lower limit value. | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number P-AXIS-00016 of affected axis. | |||||
%2: | Actual value [0,1%] | ||||
Current percentage share value P-AXIS-00095. | |||||
%3: | Lower limit value [0,1%] | ||||
Lower limit value for percentage share value. | |||||
%4: | Corrected value [0,1%] | ||||
Corrected percentage share value P-AXIS-00095. | |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110134 | Percentage for interpolation feed rate in manual mode too big. | ||||
| Description | While active manual mode with parallel interpolation (G201) the axis dynamic values are distributed with percentage value between path interpolation and axis specific manual mode interpolator. The percentage share value of maximum velocity P-AXIS-00212 for path interpolator is made via P-AXIS-00095. The percentage share value of maximum velocity for manual mode is set to upper limit value. | |||
Reaction | Class | 1 | None. | ||
Solution | Class | 1 | Percentage share value setting of P-AXIS-00095 smaller than upper limit value. | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number P-AXIS-00016 of affected axis. | |||||
%2: | Actual value [0,1%] | ||||
Current percentage share value P-AXIS-00095. | |||||
%3: | Upper limit value [0,1%] | ||||
Upper limit value for percentage share value. | |||||
%4: | Corrected value [0,1%] | ||||
Corrected percentage share value P-AXIS-00095. | |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110135 | Percentage for interpolation acceleration in manual mode too small. | ||||
| Description | While active manual mode with parallel interpolation (G201) the axis dynamic values are distributed with percentage value between path interpolation and axis specific manual mode interpolator. The percentage share value of maximum acceleration P-AXIS-00008 for path interpolator is made via P-AXIS-00094. The percentage share value of maximum velocity for manual mode is set to lower limit value. | |||
Reaction | Class | 1 | None. | ||
Solution | Class | 1 | Percentage share value setting of P-AXIS-00094 bigger than lower limit value. | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number P-AXIS-00016 of affected axis. | |||||
%2: | Actual value [0,1%] | ||||
Current percentage share value P-AXIS-00094. | |||||
%3: | Lower limit value [0,1%] | ||||
Lower limit value for percentage share value. | |||||
%4: | Corrected value [0,1%] | ||||
Corrected percentage share value P-AXIS-00094. | |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110136 | Percentage for interpolation acceleration in manual mode too big. | ||||
| Description | While active manual mode with parallel interpolation (G201) the axis dynamic values are distributed with percentage value between path interpolation and axis specific manual mode interpolator. The percentage share value of maximum acceleration P-AXIS-00008 for path interpolator is made via P-AXIS-00094. The percentage share value of maximum velocity for manual mode is set to upper limit value. | |||
Reaction | Class | 1 | None. | ||
Solution | Class | 1 | Percentage share value setting of P-AXIS-00094 smaller than upper limit value. | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number P-AXIS-00016 of affected axis. | |||||
%2: | Actual value [0,1%] | ||||
Current percentage share value P-AXIS-00094. | |||||
%3: | Upper limit value [0,1%] | ||||
Upper limit value for percentage share value. | |||||
%4: | Corrected value [0,1%] | ||||
Corrected percentage share value P-AXIS-00094. | |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110137 | Filtering time is not allowed to be 0 for operating mode "hand wheel". | ||||
| Description | While active manual mode in operation mode handwheel the parameter P-AXIS-00069 defines the number of CNC cycles which are used for average filtering of handwheel increments. The parameter P-AXIS-00069 is set to default minimum value. | |||
Reaction | Class | 1 | None. | ||
Solution | Class | 1 | Only use filter time setting P-AXIS-00069 bigger than 0. | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number P-AXIS-00016 of affected axis. | |||||
%2: | Actual value [1 µsec] | ||||
Current filter time P-AXIS-00069. | |||||
%3: | Corrected value [1 µsec] | ||||
Corrected filter time P-AXIS-00069. | |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110138 | Filtering time is exceeds limit for operating mode "hand wheel". | ||||
| Description | While active manual mode in operation mode handwheel the parameter P-AXIS-00069 defines the number of CNC cycles which are used for average filtering of handwheel increments. The parameter P-AXIS-00069 is limited by permissible maximum value. | |||
Reaction | Class | 1 | None. | ||
Solution | Class | 1 | Only use filter time setting P-AXIS-00069 smaller than upper limit value. | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number P-AXIS-00016 of affected axis. | |||||
%2: | Actual value [1 µsec] | ||||
Current filter time P-AXIS-00069. | |||||
%3: | Upper limit value [1 µsec] | ||||
Corrected filter time P-AXIS-00069. | |||||
%4: | Corrected value [1 µsec] | ||||
| |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110139 | Rapid feed rate for operating mode "incremental mode" is 0. | ||||
| Description | While active manual mode in operation mode continuous jog the parameter P-AXIS-00210 defines the rapid velocity. The parameter P-AXIS-00210 is set to minimum value. | |||
Reaction | Class | 1 | None. | ||
Solution | Class | 1 | Only use setting for P-AXIS-00210 bigger than 0. | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number P-AXIS-00016 of affected axis. | |||||
%2: | Actual value [1µm/sec or 0,001°/sec] | ||||
Current rapid velocity P-AXIS-00210. | |||||
%3: | Corrected value [1µm/sec or 0,001°/sec] | ||||
Corrected rapid velocity P-AXIS-00210. | |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110140 | Rapid feed rate for operating mode "incremental mode" exceeds limit. | ||||
| Description | While active manual mode in operation mode continuous jog the parameter P-AXIS-00210 defines the rapid velocity. The parameter P-AXIS-00210 is set to maximum permissible value. | |||
Reaction | Class | 1 | None. | ||
Solution | Class | 1 | Only use setting for P-AXIS-00210 smaller than maximum value. | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number P-AXIS-00016 of affected axis. | |||||
%2: | Actual value [1µm/sec or 0,001°/sec] | ||||
Current rapid velocity P-AXIS-00210. | |||||
%3: | Upper limit value [1µm/sec or 0,001°/sec] | ||||
Maximum permissible velocity. | |||||
%4: | Corrected value [1µm/sec or 0,001°/sec] | ||||
Corrected rapid velocity P-AXIS-00210. | |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110141 | Incremental feed rate greater than maximum incremental feed rate. | ||||
| Description | While active manual mode in operation mode continuous jog the parameter P-AXIS-00077 defines the continuous jog velocity. The parameter P-AXIS-00077 is set to maximum permissible value. | |||
Reaction | Class | 1 | None. | ||
Solution | Class | 1 | Only use setting for P-AXIS-00077 smaller than maximum value. | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number P-AXIS-00016 of affected axis. | |||||
%2: | Actual value [1µm/sec or 0,001°/sec] | ||||
Current velocity P-AXIS-00077. | |||||
%3: | Upper limit value [1µm/sec or 0,001°/sec] | ||||
Maximum permissible velocity. | |||||
%4: | Corrected value [1µm/sec or 0,001°/sec] | ||||
Corrected velocity P-AXIS-00077. | |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110142 | Jog step distance has to be positive. | ||||
| Description | While active manual mode in operation mode incremental jog the parameter P-AXIS-00232 defines the incremental jog path. The parameter P-AXIS-00232 is set to minimum permissible value. | |||
Reaction | Class | 1 | None. | ||
Solution | Class | 1 | Only use setting for P-AXIS-00232 bigger than minimum value. | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number P-AXIS-00016 of affected axis. | |||||
%2: | Actual value [0.1 µm or 0,0001°] | ||||
Current incremental jog path P-AXIS-00232. | |||||
%3: | Corrected value [0.1 µm or 0,0001°] | ||||
Corrected incremental jog path P-AXIS-00232. | |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110143 | Jog step distance greater than maximum jog step distance. | ||||
| Description | While active manual mode in operation mode incremental jog the parameter P-AXIS-00076 defines the jog velocity. The parameter P-AXIS-00076 is set to maximum permissible value. | |||
Reaction | Class | 1 | None. | ||
Solution | Class | 1 | Only use setting for P-AXIS-00076 smaller than maximum value. | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number P-AXIS-00016 of affected axis. | |||||
%2: | Actual value [1µm/sec or 0,001°/sec] | ||||
Current incremental jog velocity P-AXIS-00076. | |||||
%3: | Upper limit value [1µm/sec or 0,001°/sec] | ||||
Maximum permissible incremental jog velocity. | |||||
%4: | Corrected value [1µm/sec or 0,001°/sec] | ||||
Corrected incremental jog velocity P-AXIS-00076. | |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110144 | Positive and negative manual mode offset limits are 0. | ||||
| Description | Both positive and negative offset limits P-AXIS-00138, P-AXIS-00137 for movement range with active manual mode operation are zero. The offset limits are corrected according to specific limit values. | |||
Reaction | Class | 1 | None. | ||
Solution | Class | 1 | Setting of positive offset limit P-AXIS-00138 bigger than 0, setting of negative offset limit P-AXIS-00137 smaller than 0. | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number P-AXIS-00016 of affected axis. | |||||
%2: | Corrected value [-] | ||||
Corrected value for positive offset limit P-AXIS-00138. | |||||
%3: | Corrected value [-] | ||||
Corrected value für negative offset limit P-AXIS-00137. | |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110145 | Positive manual mode offset limit negative. | ||||
| Description | The positive offset limit P-AXIS-00138 for positive movement range with active manual mode operation is smaller than 0. The offset limit is corrected according to specific default value. | |||
Reaction | Class | 1 | None. | ||
Solution | Class | 1 | Setting of positive offset limit P-AXIS-00138 bigger than 0 | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number P-AXIS-00016 of affected axis. | |||||
%2: | Actual value [-] | ||||
Current value of P-AXIS-00138. | |||||
%3: | Corrected value [-] | ||||
Corrected value of P-AXIS-00138. | |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110146 | Negative manual mode offset limit positive. | ||||
| Description | The negative offset limit P-AXIS-00137 for negative movement range with active manual mode operation is positive. The offset limit is corrected according to specific default value. | |||
Reaction | Class | 1 | None. | ||
Solution | Class | 1 | Setting of negative offset limit P-AXIS-00137 smaller than 0 | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number P-AXIS-00016 of affected axis. | |||||
%2: | Actual value [-] | ||||
Current value of P-AXIS-00137. | |||||
%3: | Corrected value [-] | ||||
Corrected value of P-AXIS-00137. | |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110147 | maximum feed rate in machine reference search greater than vb_max. | ||||
| Description | The fast homing speed for CNC controlled homing exceeds the maximum velocity of the axis. | |||
Reaction | Class | 1 | The homing velocity is limited to the maximum velocity. | ||
Solution | Class | 1 |
| ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Actual value [1µm/sec or 0,001°/sec] | ||||
| |||||
%3: | Limit value [1µm/sec or 0,001°/sec] | ||||
| |||||
%4: | Corrected value [1µm/sec or 0,001°/sec] | ||||
| |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110148 | minimum feed rate in machine reference search greater than vb_max. | ||||
| Description | The slow homing speed for CNC controlled homing exceeds the maximum velocity of the axis. | |||
Reaction | Class | 1 | The homing velocity is limited to the maximum velocity. | ||
Solution | Class | 1 |
| ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Actual value [1µm/sec or 0,001°/sec] | ||||
| |||||
%3: | Limit value [1µm/sec or 0,001°/sec] | ||||
| |||||
%4: | Corrected value [1µm/sec or 0,001°/sec] | ||||
| |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110149 | minimum feed rate in machine reference search greater than maximum feed rate. | ||||
| Description | The slow homing speed for CNC controlled homing exceeds the fast homing velocity. | |||
Reaction | Class | 1 | The slow homing velocity is limited to the fast homing velocity. | ||
Solution | Class | 1 |
| ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Actual value [1µm/sec or 0,001°/sec] | ||||
| |||||
%3: | Limit value [1µm/sec or 0,001°/sec] | ||||
| |||||
%4: | Corrected value [1µm/sec or 0,001°/sec] | ||||
| |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110150 | Amplifier factor is 0. | ||||
| Description | The proportional gain was set to zero. This is an illegal value. | |||
Reaction | Class | 1 | Element is initialized by default value. | ||
Solution | Class | 1 | Correct parameter list of axis. | ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Incorrect value [0.01/sec] | ||||
| |||||
%3: | Corrected value [0.01/sec] | ||||
| |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110151 | D/A converter resolution (denominator) is 0. | ||||
| Description | The resolution for the digital/analog converter (denominator) is specified with zero. This value is illegal. | |||
Reaction | Class | 1 | Element is initialized by default value. | ||
Solution | Class | 1 | Correct parameter list of axis. | ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Actual value [-] | ||||
| |||||
%3: | Corrected value [-] | ||||
| |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110153 | Illegal value for minimum position lag/software limit switch. | ||||
| Description | The minimal position lag limit P-AXIS-00169 is set to big. The value is limited by a quarter of the overall movement range (distance between negative and positive software limit switches). | |||
Reaction | Class | 1 | Limitation to a quarter of movement range | ||
Solution | Class | 1 | Decrease of value in parameterlist. | ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Actual value [0.1 µm or 0,0001°] | ||||
| |||||
%3: | Limit value [0.1 µm or 0,0001°] | ||||
P-AXIS-00177, P-AXIS-00178 | |||||
%4: | Corrected value [0.1 µm or 0,0001°] | ||||
| |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110154 | Dynamical position lag exceeds range of permissible values. | ||||
| Description | The factor P-AXIS-00167 of the position lag monitoring has been initialized to big. The factor has dependent on the type of position lag monitoring P-AXIS-00172 an different meaning. | |||
Reaction | Class | 1 | The position lag factor is limited by the maximum value. | ||
Solution | Class | 1 | Decrease of value in parameterlist. | ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Actual value [-] | ||||
| |||||
%3: | Limit value [-] | ||||
| |||||
%4: | Corrected value [-] | ||||
| |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110162 | Interpreter can not evaluate given list. | |||
| Description | CNC wants evaluate an axis parameter list or compensation value list, which should be exist as file, but detects that the file doesn’t exist in path. | ||
Reaction | Class | 3 |
| |
Solution | Class | 1 | · If the message appear during startup sequence the pathes given by parameters P-STUP-00015 and P-STUP-00017 have to be checked. · If the message appears after an order to access a file, check the path send by the order. | |
Error type | - | |||
| ||||
110163 - 110181 |
| |||
| Description | This error message informs about internal states, error solutions and the place of error in the source.Please give the complete error message data to the CNC manufacturer. | ||
Reaction | Class | 2 |
| |
Solution | Class | 8 | Restart of NC-control necessary. | |
110182 | Factor for spindle speed is 0. | ||||
| Description | The given factor for the monitoring of the spindle revolution P-AXIS-00217 equals zero. | |||
Reaction | Class | 1 | Value is initialized with a default. | ||
Solution | Class | 1 | Correct value in parameter list. | ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Incorrect value [-] | ||||
| |||||
%3: | Corrected value [-] | ||||
| |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110183 | Type of axis may not be changed after system booted. | ||||
| Description | The parameter P-AXIS-00018 for type of axis cannot be changed while CNC kernel is running. The new axis type is not transfered, the previous active axis type remains valid. | |||
Reaction | Class | 1 | None. | ||
Solution | Class | 1 | Only change axis type P-AXIS-00018 in configuration mode or if CNC kernel does not run respectively. | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number P-AXIS-00016 of affected axis. | |||||
%2: | Actual value [-] | ||||
Current value of P-AXIS-00018. | |||||
%3: | Corrected value [-] | ||||
Corrected value of P-AXIS-00018. | |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110184 - 110198 |
| |||
| Description | This error message informs about internal states, error solutions and the place of error in the source.Please give the complete error message data to the CNC manufacturer. | ||
Reaction | Class | 3 |
| |
Solution | Class | 8 | Restart of NC-control necessary. | |
110199 | Received unknown axis. | ||||
| Description |
| |||
Reaction | Class | 3 |
| ||
Solution | Class | 6 |
| ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
Error type | - | ||||
| |||||
110200 - 110209 |
| |||
| Description | This error message informs about internal states, error solutions and the place of error in the source.Please give the complete error message data to the CNC manufacturer. | ||
Reaction | Class | 2 |
| |
Solution | Class | 8 | Restart of NC-control necessary. | |
110210 | Corrected unknown type of axis to "ACHSTYP_TRANSLATOR". | ||||
| Description | The axis type P-AXIS-00018 in the paramter list is not known. | |||
Reaction | Class | 1 | The type is set to TRANSLATOR (=1) | ||
Solution | Class | 1 | Correct value in parameter list. | ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Actual value [-] | ||||
| |||||
%3: | Corrected value [-] | ||||
| |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110211 | Corrected unknown drive type to "ACHSTYP_SIMU". | ||||
| Description | The specified drive type is unknown. | |||
Reaction | Class | 1 | The type is set to SIMULATION (= 4) | ||
Solution | Class | 1 | Correct value in parameter list. | ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Actual value [-] | ||||
| |||||
%3: | Corrected value [-] | ||||
| |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110212 |
| |||
| Description | This error message informs about internal states, error solutions and the place of error in the source.Please give the complete error message data to the CNC manufacturer. | ||
Reaction | Class | 3 |
| |
Solution | Class | 8 | Restart of NC-control necessary. | |
110213 | Unknown characteristic acceleration curve. | ||||
| Description | An unknown type P-AXIS-00202 for acceleration characteristic curve was given. Following types are allowed: 0 – off 1 – Hyperbel 4. Grades 2 – Polynom 3. Grades 3 – corresponding to asynchronous motor 1/n bzw. 1/n² | |||
Reaction | Class | 1 | Turn off type. | ||
Solution | Class | 1 | Correct the typ in the parameter list. | ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Incorrect value [-] | ||||
| |||||
%3: | Corrected value [-] | ||||
| |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110214 | Limit of rotational speed is smaller than permissible value. | ||||
| Description | The limit revolution P-AXIS-00103 for acceleration characteristic curve was given to big. | |||
Reaction | Class | 1 | Turn off type. | ||
Solution | Class | 1 | Correct the limit revolution in the axis list. | ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Incorrect value [1µm/sec or 0,001°/sec] | ||||
| |||||
%3: | Lower limit value [1µm/sec or 0,001°/sec] | ||||
| |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110215 | Acceleration limit is greater than permissible value. | ||||
| Description | Acceleration limit P-AXIS-00007 of acceleration characteristic curve was specified to big. This value must not be above the maximum axis acceleration P-AXIS-00008. | |||
Reaction | Class | 1 | Limitation of value | ||
Solution | Class | 1 | Correct specified acceleration in the parameter list. | ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Actual value [1µm/sec or 0,001°/sec] | ||||
| |||||
%3: | Limit value [1µm/sec or 0,001°/sec] | ||||
| |||||
%4: | Corrected value [1µm/sec or 0,001°/sec] | ||||
| |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110216 | Acceleration minimum is smaller than permissible value. | ||||
| Description | Minimim acceleration P-AXIS-00010 of acceleration characteristic curve was specified to big. This value must not be above the constant acceleration P-AXIS-00007. | |||
Reaction | Class | 1 | Limitation of value | ||
Solution | Class | 1 | Correct specified acceleration in the parameter list. | ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Actual value [1µm/sec or 0,001°/sec] | ||||
| |||||
%3: | Limit value [1µm/sec or 0,001°/sec] | ||||
| |||||
%4: | Incorrect value [1µm/sec or 0,001°/sec] | ||||
| |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110217 | Number of sections within list for leadscrew error compensation. | ||||
| Description | Within the list for leadscrew error compensation there is the parameter P-COMP-00020 (siehe [COMP]) which is used to specify the number of entries into that list. During interpretation of that list by the CNC it is checked if the specified number of list entries exceeds the lower or upper number of entries that are necessary or maximal possible to correctly use the leadscrew error compensation. | |||
Reaction | Class | 3 | The reaction of the CNC depends whether the number given by P-COMP-00020 exceeds the lower or upper limit for the number of list entries. If the value of P-COMP-00020 is · 0 CNC recovers using 2 entries that are initialized with 0 · 1 CNC recovers adding internal 1 entry and initializes him with the data of the first entry. · > obere Grenze | ||
Solution | Class | 7 | Check the value given by parameter P-COMP-00020. The value must be≥2 und≤ the value that is displayed as parameter 2 of this message. | ||
Parameter | %1: | Logical axis number [-] | |||
From user by parameter P-COMP-00020 specified number of entries in the list for compensation of leadscrew errors. | |||||
%2: | Incorrect value [-] | ||||
Shows how many list entries are used to do the leadscrew error compensation. | |||||
%3: | Lower limit value [-] | ||||
| |||||
%4: | Upper limit value [-] | ||||
| |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110218 | Illegal grating of sections for leadscrew error compensation. | ||||
| Description | The interval between 2 interpolation points out of the list with correction values for leadscrew error compensation is defined by parameter P-COMP-00009. The message appears, because the value for the interval is < 0. | |||
Reaction | Class | 3 | Correction of the value | ||
Solution | Class | 7 | User has to define a value≥0 at parameter P-COMP-00009. | ||
Parameter | %1: | Logical axis number [-] | |||
The value the user defined at parameter P-COMP-00009. | |||||
%2: | Incorrect value [Increment] | ||||
The CNC uses this value instead the user defined value. | |||||
%3: | Lower limit value [Increment] | ||||
| |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110219 | Maximum speed of manual mode exceeds axis limit. | ||||
| Description | The given maximum velocity for manual mode P-AXIS-00213 exceeds the general maximum velocity of the axis P-AXIS-00212. | |||
Reaction | Class | 1 | Velocity is limited to maximum axis velocity. | ||
Solution | Class | 1 | Correct parameter in axis list. | ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Incorrect value [1µm/sec or 0,001°/sec] | ||||
| |||||
%3: | Corrected value [1µm/sec or 0,001°/sec] | ||||
| |||||
%4: | Instance [-] | ||||
Actual gear Step P-AXIS-00136 | |||||
%5: | Upper limit value [1µm/sec or 0,001°/sec] | ||||
Maximum axis velocity P-AXIS-00212 | |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110220 | Rapid traverse rate of manual mode exceeds axis limit. | ||||
| Description | The given maximum velocity for rapid speed manual mode P-AXIS-00210 exceeds the general maximum velocity of the axis P-AXIS-00212. | |||
Reaction | Class | 1 | Velocity is limited to maximum axis velocity for rapid speed. | ||
Solution | Class | 1 | Correct parameter in axis list. | ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Actual value [1µm/sec or 0,001°/sec] | ||||
| |||||
%3: | Corrected value [1µm/sec or 0,001°/sec] | ||||
| |||||
%4: | Instance [-] | ||||
Actual gear Step P-AXIS-00136 | |||||
%5: | Upper limit value [1µm/sec or 0,001°/sec] | ||||
Maximum axis velocity P-AXIS-00209 | |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110221 | Tip speed exceeds max. speed of axis. | ||||
| Description | The given maximum velocity for continuous manual mode P-AXIS-00077 exceeds the general maximum velocity of the axis P-AXIS-00213. | |||
Reaction | Class | 1 |
| ||
Solution | Class | 1 |
| ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Actual value [1µm/sec or 0,001°/sec] | ||||
| |||||
%3: | Corrected value [1µm/sec or 0,001°/sec] | ||||
| |||||
%4: | Instance [-] | ||||
Actual gear Step P-AXIS-00136 | |||||
%5: | Upper limit value [1µm/sec or 0,001°/sec] | ||||
Maximum axis velocity in manaul mode P-AXIS-00213 | |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110222 | Jog speed exceeds max. speed of axis. | ||||
| Description | The given maximum velocity for incremental manual mode P-AXIS-00076 exceeds the general maximum velocity of the axis P-AXIS-00213. | |||
Reaction | Class | 1 |
| ||
Solution | Class | 1 |
| ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Actual value [1µm/sec or 0,001°/sec] | ||||
| |||||
%3: | Corrected value [1µm/sec or 0,001°/sec] | ||||
| |||||
%4: | Instance [-] | ||||
Actual gear Step P-AXIS-00136 | |||||
%5: | Upper limit value [1µm/sec or 0,001°/sec] | ||||
Maximum axis velocity in manaul mode P-AXIS-00213 | |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110225 - 110227 |
| |||
| Description | This error message informs about internal states, error solutions and the place of error in the source.Please give the complete error message data to the CNC manufacturer. | ||
Reaction | Class | 2 |
| |
Solution | Class | 8 | Restart of NC-control necessary. | |
110228 | Logical axis number in axis parameter list and in command-PDU not equal. | ||||
| Description | CNC gets an order to parametrize an axis with a data set from a given list. The message appears, because the number of the logical axis in the list isn’t the same as that of the axis. | |||
Reaction | Class | 3 | Abort interpretation of the list. | ||
Solution | Class | 7 | Check which list to use for axis parametrization. May be you have to change the number of the logical axis in the list or have to use another list. | ||
Parameter | %1: | Actual value [-] | |||
Number of logical axis. The list that should be interpreted contains that number. | |||||
%2: | Expected value [-] | ||||
Number of logical axis, which should be parametrized with the values contained in list. | |||||
Error type | - | ||||
| |||||
110229 | Logical axis number in compensation data list and in command-PDU not equal. | ||||
| Description | A logical axis should use a list with compensation values. Therefore this list is interpreted. While interpreting it is detected, that the number of the logical axis of the compensation value list isn’t that number of the logical axis that should use this list. | |||
Reaction | Class | 3 | Abort interpretation of the compensation value list. | ||
Solution | Class | 7 | Check which list to use for compensation. May be you have to change the number of the logical axis in the list or have to use another list. | ||
Parameter | %1: | Actual value [-] | |||
Number of logical axis. The compensation list that should be interpreted contains that number (P-COMP-00001). | |||||
%2: | Expected value [-] | ||||
Number of logical axis, which should use the compensation list (P-STUP-00036). | |||||
Error type | - | ||||
| |||||
110230 | Number of gear steps of a C-axis out of range. | ||||
| Description | In axis with axis type spindle P-AXIS-00018 the entry for default CAX gear step P-AXIS-00052 has invalid value. With use of CNC command < #CAX > this default gear step is used for the rotary C-axis. The CAX gear step is set to default value. Further information to CAX functionality see [PROG]. | |||
Reaction | Class | 1 | None. | ||
Solution | Class | 1 | Use correct entry for default gear step P-AXIS-00052. | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number P-AXIS-00016 of affected axis. | |||||
%2: | Actual value [-] | ||||
Current default gear step P-AXIS-00052. | |||||
%3: | Limit value [-] | ||||
Maximum value of gear step. | |||||
%4: | Corrected value [-] | ||||
Corrected value for default CAX gear step P-AXIS-00052. | |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110231 | A translatory axis cannot be a C-axis. | ||||
| Description | Within the axis mode P-AXIS-00015 (bitcoded) the translatoric axis is specified as C-axis. This is just possible for rotatory axis or spindles. | |||
Reaction | Class | 1 | The axis mode is set to linear. C-axis bit is cleared. | ||
Solution | Class | 1 | Correction of axis parameter list | ||
Parameter | %1: | Logical axis number [-] | |||
P-AXIS-00016 | |||||
%2: | Incorrect value [-] | ||||
P-AXIS-00015 | |||||
%3: | Corrected value [-] | ||||
P-AXIS-00015 | |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110232 | hw_addr_index out of range. | ||||
| Description | The given default hardware number of the gear step is not valid. | |||
Reaction | Class | 1 | Hardwarenumber ist set to default value. | ||
Solution | Class | 1 | Correct value in parameter list. | ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Actual value [-] | ||||
| |||||
%3: | Upper limit value [-] | ||||
| |||||
%4: | Corrected value [-] | ||||
| |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110233 / 110234 |
| |||
| Description | This error message informs about internal states, error solutions and the place of error in the source.Please give the complete error message data to the CNC manufacturer. | ||
Reaction | Class | 3 |
| |
Solution | Class | 8 | Restart of NC-control necessary. | |
110236 | Led screw error compensation without correction value list. | ||||
| Description | CNC detects inconsistent parametrization concerning leadscrew error compensation. Within an axis configuration list by parameter P-AXIS-00175 leadscrew error compensation ist activated. Therefore CNC expects correct data in which path to get a list with compensation values and what’s the name of file. User provides that data by parameter P-STUP-00016, P-STUP-00017, P-STUP-00036 of the startup list. In the corresponding compensation value list it is necessary to provide correct values by parameter P-COMP-00001 and P-COMP-00020 for the leadscrew error compensation. | |||
Reaction | Class | 1 | CNC deactivates lead screw error compensation. | ||
Solution | Class | 1 | · Check parameters · If you don’t need leadscrew error compensation set parameter P-AXIS-00175 to 0. | ||
Parameter | %1: | Logical axis number [-] | |||
Parameter P-AXIS-00016 from a axis configuration list which have lead screw error compensation configured by setting P-AXIS-00175 to 1. | |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110237 | Order of filter too big. | ||||
| Description | The specified order of the filter is too high. | |||
Reaction | Class | 1 | Warning, the filter order is set to the maximum permissible value. | ||
Solution | Class | 1 | Correct the filter order | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number P-AXIS-00016 of affected axis | |||||
%2: | Actual value [-] | ||||
Number of the affected filter | |||||
%3: | Actual value [-] | ||||
Filter type | |||||
%4: | Incorrect value [-] | ||||
Invalid filter order | |||||
%5: | Corrected value [-] | ||||
Corrected filter order | |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110238 | Filter prototype not permitted. | ||||
| Description | The specified prototype of the filter is unknown. | |||
Reaction | Class | 1 | The filter prototype is set to 1 (critical damping). | ||
Solution | Class | 1 | Correct the filter prototype P-AXIS-00153 | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis numberof affected axis | |||||
%2: | Actual value [-] | ||||
Number of affected filter | |||||
%3: | Actual value [-] | ||||
Invalid filter prototype | |||||
%4: | Corrected value [-] | ||||
Corrected filter prototype P-AXIS-00153 | |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110239 | Filter type not permitted. | ||||
| Description | The specified filter type is unknown. You just can specify the described filter types. | |||
Reaction | Class | 3 | The filter is deactivated. | ||
Solution | Class | 7 | Correct the filter type P-AXIS-00204 | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number P-AXIS-00016 of affected axis | |||||
%2: | Actual value [-] | ||||
Number of affected filter | |||||
%3: | Incorrect value [-] | ||||
Invalid filter type | |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110240 | Filter share exceeds permissible range. | ||||
| Description | The parameter defines the signal share in percent, which is processed by the filter. The given part for the signal is out of range. | |||
Reaction | Class | 1 | The signal share is set to the corresponding limit (0 or 100 percent). | ||
Solution | Class | 1 |
| ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number P-AXIS-00016 of affected axis | |||||
%2: | Actual value [0,1%] | ||||
Number of affected filter | |||||
%3: | Actual value [0,1%] | ||||
Invalid filter share P-AXIS-00164 | |||||
%4: | Corrected value [-] | ||||
Corrected filter share P-AXIS-00164 | |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110241 | Acceleration at current limit is 0. | ||||
| Description | The acceleration for rapid movements P-AXIS-00004 of the non linear slope (jerk limited) is given with zero. The acceleration must be bigger 0. | |||
Reaction | Class | 1 | Initialization of acceleration with default value | ||
Solution | Class | 1 | Correct value in parameter list | ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Actual value [1mm/sec^2 or 1°/sec^2] | ||||
| |||||
%3: | Corrected value [1mm/sec^2 or 1°/sec^2] | ||||
| |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110242 | Acceleration at current limit is greater than axis acceleration. | ||||
| Description | The acceleration P-AXIS-00004 for rapid movemnts of the non linear slope (jerk limited) is bigger than the maximum acceleration P-AXIS-00008 of the axis. | |||
Reaction | Class | 1 | Limitation of acceleration with maximum value | ||
Solution | Class | 1 | Correct value in parameter list | ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Actual value [1mm/sec^2 or 1°/sec^2] | ||||
| |||||
%3: | Upper limit value [1mm/sec^2 or 1°/sec^2] | ||||
| |||||
%4: | Corrected value [1mm/sec^2 or 1°/sec^2] | ||||
| |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110243 | Ramp time for acceleration at current limit too small. | ||||
| Description | The time P-AXIS-00200 (ramp time) for in-/decreasing the maximum current limit acceleration P-AXIS-00004 of the jerk limited slope is smaller than the minimal ramp time P-AXIS-00201 of the axis. | |||
Reaction | Class | 1 | Limitation of ramp time with minimal value | ||
Solution | Class | 1 | Correct value in parameter list | ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Actual value [1 µsec] | ||||
| |||||
%3: | Lower limit value [1 µsec] | ||||
| |||||
%4: | Corrected value [1 µsec] | ||||
| |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
110244 | Logical axis number of master axis is missing for GANTRY operation. | ||||
| Description | The axis is marked as slave axis of a gantry link with P-AXIS-00015 but the correct master axis entry P-AXIS-00070 is missing. | |||
Reaction | Class | 3 | None. | ||
Solution | Class | 7 | Use correct entry for logical axis number P-AXIS-00070 of leading master axis. | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number P-AXIS-00016 of affected axis. | |||||
%2: | Logical axis number [-] | ||||
Current logical axis number of leading master axis P-AXIS-00070. | |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||