ID-range 80000-80249

80000

Dead time exceeds maximum value.

 

Description

The specified dead time of the simulation drive is invalid. The dead time is defined in the parameter P-AXIS-00194 as a multiple of the cycle time of the geometry data processing task (s. axis parameters list [AXIS, Axis Parameter]).

Reaction

Class

1

Warning, dead time is reduced to maximum permissible value

Solution

Class

1

Correct the value of the dead time in the axis parameter list s. P-AXIS-00194

Parameter

%1:

Logical axis number [-]

Logical axis number of affected axis s. P-AXIS-00016

%2:

Actual value [-]

Specified value for the dead time s. P-AXIS-00194

%3:

Upper limit value [-]

Maximum permissible value for the dead time s. P-AXIS-00194

Error type

-

 

80001 / 80004

Troubleshooting classes

 

Description

This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer.

Reaction

Class

2

 

Solution

Class

8

Restart of NC-control necessary.

80005

Number of axis group exceeds range or is 0.

 

Description

When taking over the axis configuration, it was detected, that the number of the axis group is invalid. The axis groups are configured in the channel parameters list (s. [CHAN, Channel Parameter]). The control presently supports only one axis group.

Reaction

Class

3

Job processing aborted

Solution

Class

6

Correct the configuration of the axis groups in the channel parameters list.

Parameter

%1:

Logical axis number [-]

Logical axis number of affected axis s. P-CHAN-00035, P-AXIS-00016

%2:

Actual value [-]

Invalid axis group number

%3:

Upper limit value [-]

Maximum permissible number of axis groups

Error type

-

 

80006

Axis number already used.

 

Description

The given logical axis number is already used for a different axis or spindle.

Reaction

Class

3

Job processing aborted

Solution

Class

6

Correct axis configuration s. [CHAN]

Parameter

%1:

Logical axis number [-]

The logical axis number, which exists already s. P-CHAN-00035

%2:

Actual value [-]

index of axis

Error type

-

 

80007

Number of axes within group greater than ANZ_ACHSEN_IN_GR or equal to 0.

 

Description

The received axis number is greater than the maximum permissible number of axes in an axis group (application dependent) or it is zero.

Reaction

Class

3

Job processing aborted

Solution

Class

6

Correct axis configuration

Parameter

%1:

Actual value [-]

Invalid axis number

%2:

Upper limit value [-]

Maximum permissible number of axis in an axes group (application dependent)

Error type

-

 

80008

Axis index already used within group.

 

Description

Two or more axes of the axis group use the same axis index.

Reaction

Class

3

Job processing aborted

Solution

Class

6

Correct axis configuration

Parameter

%1:

Logical axis number [-]

Logical axis number of affected axis s. P-AXIS-00016

%2:

Actual value [-]

Axis index

%3:

Actual value [-]

Number of affected axis group

Error type

-

 

80009

No axis specified within axis data.

 

Description

No axis configured.

Reaction

Class

3

Job processing aborted

Solution

Class

6

Correct axis configuration

Error type

-

 

80010

Number of axis groups not coherent.

 

Description

The given numbers of axis groups are not coherent.

Reaction

Class

3

Job processing aborted

Solution

Class

6

Correct configuration of axis groups s. [CHAN]

Parameter

%1:

Actual value [-]

Expected axis group number

Error type

-

 

80011

Number of axis not coherent within group.

 

Description

The given numbers of axis are not coherent within axis group.

Example (extract from channel parameters list):

gruppe[0].achse[0].bezeichnung X ACHSE1
...
gruppe[0].achse[2].bezeichnung A
...
gruppe[0].achse[3].bezeichnung W1
...
Solution:
gruppe[0].achse[0].bezeichnung X ACHSE1
...
gruppe[0].achse[1].bezeichnung A
...
gruppe[0].achse[2].bezeichnung W1
...

Reaction

Class

3

Job processing aborted

Solution

Class

6

Correct axis configuration s. [CHAN]

Parameter

%1:

Actual value [-]

Number of affected axis group

%2:

Expected value [-]

Expected axis number

Error type

-

 

80016 - 80043

 

 

Description

This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer.

Reaction

Class

2

 

Solution

Class

8

Restart of NC-control necessary.

80044

Attenuation greater than 1.

 

Description

The attenuation value of the simulation drive (ANTR_TYP_SIMU) is invalid. It must be smaller than one.

The attenuation value is specified in the axis parameter list (s. [AXIS - Drive type simulation]) as quotient of the parameters P-AXIS-00051 and P-AXIS-00050.

Reaction

Class

1

Warning, attenuation value is reduced to maximum permissible value.

Solution

Class

1

Correct attenuation in the axis parameter

Parameter

%1:

Logical axis number [-]

Logical axis number of affected axis s. P-AXIS-00016

%2:

Actual value [-]

Specified attenuation value s. P-AXIS-00050, P-AXIS-00051

%3:

Limit value [-]

Maximum permissible attenuation value

%4:

Corrected value [-]

Corrected attenuation value

Error type

-