ID-range 70250-70499
70250 | Invalid resolution of master axis for cross compensation. | ||||
| Description | The correction values for cross compensation (s. [FCT-C5 - Cross compensation])were specified in increments in the corresponding compensation data list (s. [COMP, Axis Compensation]). Increments are only allowed for path resolutions of the measuring system of one (s. P-AXIS-00234, P-AXIS-00233). However, the master axis (the axis, which position influences the slave axis) uses a different path resolution than one. Solution:
| |||
Reaction | Class | 3 | Warning, compensation is turned off for the slave axis | ||
Solution | Class | 1 | Adjust parameter P-COMP-00003 and the compensation values | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number of the slave axis s. P-AXIS-00016 | |||||
%2: | Logical axis number [-] | ||||
Logical axis number of affected master axis s. P-AXIS-00016, P-COMP-00005 | |||||
%3: | Incorrect value [-] | ||||
Path resolution of the measuring system of the master axis s. P-AXIS-00233, P-AXIS-00234 | |||||
%4: | Expected value [Increment] | ||||
Expected path resolution of the measuring system s. P-AXIS-00233, P-AXIS-00234 | |||||
Error type | 11, Error message from position controller. | ||||
| |||||
70251 | Invalid resolution of master axis for plane compensation. | ||||
| Description | The correction values for plane compensation (s. [FCT-C5 - Plane compensation]) were specified in increments in the corresponding compensation data list (s. [COMP]). Increments are only allowed for path resolutions of the measuring system of one (s. P-AXIS-00234, P-AXIS-00233). However, one of the master axes (the axes, which position influences the slave axis) uses a different path resolution than one. Solution:
| |||
Reaction | Class | 3 | Warning, compensation is turned off for the slave axis | ||
Solution | Class | 1 | Adjust parameter P-COMP-00008 and the compensation values | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number of affected slave axis s. P-AXIS-00016 | |||||
%2: | Logical axis number [-] | ||||
Logical axis number of affected master axis s. P-AXIS-00016, P-COMP-00014, P-COMP-00015 | |||||
%3: | Incorrect value [-] | ||||
Path resolution of the measuring system of the master axis s. P-AXIS-00233, P-AXIS-00234 | |||||
%4: | Expected value [Increment] | ||||
Expected path resolution of the measuring system s. P-AXIS-00233, P-AXIS-00234 | |||||
Error type | 11, Error message from position controller. | ||||
| |||||
70252 | Counter axis can not be commanded with command values. | ||||
| Description | An axis that is configured as counter axis only was commanded to do a motion. | |||
Reaction | Class | 5 | Immediate axis stop | ||
Solution | Class | 6 | Do reset. Check motion command respectively configuration setting for this axis. | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number P-AXIS-00016 of the axis. | |||||
%2: | Drive type [-] | ||||
Drive type P-AXIS-00020 | |||||
%3: | Actual value [-] | ||||
BF LR command bit field | |||||
%4: | Block number [-] | ||||
Block number of the NC program respectively instruction number, in which the error occurred. | |||||
Error type | 11, Error message from position controller. | ||||
| |||||
70253 | Active program in channel: Switch on/off of axis compensation is delayed. | ||||
| Description | An axis compensation was turned on or off during actualizing the axis parameters. Therefore, it is necessary to modify the command and actual positions in the position controller for this axis. Since there is program executed in the NC channel, the compensation is turned on or off at program end to prevent an interfering with the program. See parameters:
| |||
Reaction | Class | 1 | Warning, activation or deactivation of compensation for the affected axis is delayed until program end. | ||
Solution | Class | 1 |
| ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number of affected slave axis s. P-AXIS-00016 | |||||
%2: | Actual value [-] | ||||
State of axis compensation before actualizing the axis parameters (0 = inactive, 1 = active) | |||||
%3: | Actual value [-] | ||||
State of axis compensation after actualizing the axis parameters (0 = inactive, 1 = active) | |||||
Error type | 11, Error message from position controller. | ||||
| |||||
70254 | Axis is to be compensated, although the required drive releases are missing. | ||||
| Description | One or more axis compensations (s. [FCT-C5, Axis compensations]) are active for the affected axis. Its position is to be corrected, since the position of one master axis has changed. However, the axis cannot move, since the required drive releases are missing. | |||
Reaction | Class | 7 | Controlled stop of the affected axis. | ||
Solution | Class | 5 | Set drive releases or turn axis compensation(s) off | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number of affected slave axis s. P-AXIS-00016 | |||||
%2: | Drive type [-] | ||||
Drive type of affected axis s. P-AXIS-00020 | |||||
%3: | Block number [-] | ||||
Logical axis number of moved master axis P-COMP-00005, P-COMP-00014, P-COMP-00015 | |||||
%4: | Logical axis number [-] | ||||
Block number of the NC program in the channel of the master axis, in which the error occurred. | |||||
Error type | 11, Error message from position controller. | ||||
| |||||
70255 | Axis is to be compensated, but a movement of the drive is not possible. | ||||
| Description | One or more axis compensations (s. [FCT-C5]) are active for the affected axis. Its position must be corrected, since the position of one master axis has changed. However, the axis cannot move, since an axis-specific or channel-specific feedhold is set for the axis by the PLC. | |||
Reaction | Class | 7 | Controlled stop of the affected axis. | ||
Solution | Class | 5 | Remove feedhold or turn axis compensation(s) off | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number of affected slave axis s. P-AXIS-00016 | |||||
%2: | Drive type [-] | ||||
Drive type of affected axis s. P-AXIS-00020 | |||||
%3: | Block number [-] | ||||
Logical axis number of moved master axis P-COMP-00005, P-COMP-00014, P-COMP-00015 | |||||
%4: | Logical axis number [-] | ||||
Block number of the NC program in the channel of the master axis, in which the error occurred. | |||||
Error type | 11, Error message from position controller. | ||||
| |||||
70256 | Number of cycles for smooth coupling/decoupling of plane comp. exceeds max limit. | ||||
| Description | The given number of filter cycles (s. P-COMP-00027) in the compensation data list (s. [COMP - Plane compensation]) is greater than the maximum permissible cycles. The filter is used in the plane compensation (s. [FCT-C5 - Plane compensation]) for driving out the compensation value in several position controller cycles. The number of filter cycles is reduced to the maximum permissible value. | |||
Reaction | Class | 1 | Warning, reduction of filter cycles on maximum permissible value. | ||
Solution | Class | 1 | Reduce the filter cycles in the axis compensation list s. P-COMP-00027 | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number of affected slave axis s. P-AXIS-00016 | |||||
%2: | Actual value [-] | ||||
Number of filter cycles given in the compensation data list s. P-COMP-00027 | |||||
%3: | Corrected value [-] | ||||
Number of maximum permissible filter cycles | |||||
%4: | Block number [-] | ||||
Block number of the NC program, in which the error occurred. | |||||
Error type | 11, Error message from position controller. | ||||
| |||||
70259 | Coefficient (gradient) of temperature compensation exceeds valid range. | ||||
| Description | The temperature compensation (s. [FCT-C5]) uses a linear straight line to approximate the correction values. The gradient of the straight line is given in the parameter P-AXIS-00274 in dependency of temperature. Alternatively it can be written over a direct ADS access to the task GEO (port 551, TEMPC::coefficient IGrp = 0x20300 IOffs = 0x10043). The actual value of gradient however is not within valid range. | |||
Reaction | Class | 1 | Warning, automatic correction of gradient to maximum or minimum permissible value. | ||
Solution | Class | 1 | Correct value for gradient (via ADS or by actualizing the axis parameter list). | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number of affected axis (s. P-AXIS-00016) | |||||
%2: | Incorrect value [-] | ||||
Incorrect value of P-AXIS-00274 | |||||
%3: | Limit value [-] | ||||
Maximum permissible value for gradient P-AXIS-00274 | |||||
%4: | Limit value [-] | ||||
Minimum permissible value for gradient P-AXIS-00274 | |||||
%5: | Corrected value [-] | ||||
Corrected value for parameter P-AXIS-00274 | |||||
Error type | 11, Error message from position controller. | ||||
| |||||
70261 | Terminal signals error. | ||||
| Description | In the status byte delivered from an intelligent bus terminal the error indication is set. With this flag an internal error in the bus terminal is indicated. | |||
Reaction | Class | 8 | Output of error message, stop of axis. | ||
Solution | Class | 6 | Correct error condition in the bus terminal. Further information about the error cause might be seen on LEDs directly at the bus terminal or might be read out with diagnosis software from the terminal. Look at manufacturer documentation. | ||
Parameter | %1: | Actual value [-] | |||
Logical axis number of affected axis (s. P-AXIS-00016) | |||||
%2: | Actual value [-] | ||||
String indicating the terminal type, e. g. KL2541. | |||||
%3: | Actual value [-] | ||||
Status value from the terminal that caused the error. | |||||
Error type | - | ||||
| |||||
70262 | No position encoder configured for this axis. | ||||
| Description | In the cyclic telegram of the actual values of the axis no actual position is configured. Only spindles can be operated without position sensors. | |||
Reaction | Class | 5 | Output of error message, stop of axis. | ||
Solution | Class | 7 | If the axis is no spindle axis configure an actual positioning the cyclic telegram. If axis is a spindle set parameter P-AXIS-00018 to 4. | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number of affected axis (s. P-AXIS-00016) | |||||
%2: | Incorrect value [-] | ||||
Configured axis type (P-AXIS-00018). | |||||
%3: | Logical axis number [-] | ||||
| |||||
Error type | - | ||||
| |||||
70263 | Homing method (homing_type) of master-/slave axis is different. | ||||
| Description | Entry P-AXIS-00299 has for master- and slave axis of different values. | |||
Reaction | Class | 1 | Output of error message, P-AXIS-00299 of the slave axis is set to the value of the master axis.. | ||
Solution | Class | 1 | Assign the same value for P-AXIS-00299 of master and slave axis. | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number of slave axis (P-AXIS-00016). | |||||
%2: | Logical axis number [-] | ||||
Logical axis number of master axis (P-AXIS-00016). | |||||
%3: | Incorrect value [-] | ||||
Entry for P-AXIS-00299 for slave axis. | |||||
%4: | Incorrect value [-] | ||||
Entry for P-AXIS-00299 for master axis. | |||||
%5: | Corrected value [-] | ||||
Corrected value of P-AXIS-00299 for slave axis. | |||||
Error type | - | ||||
| |||||
70264 | An axis collision was detected for an axis of a GANTRY system. | ||||
| Description | This is a subsequent error message of the collision monitoring function (s. [FCT-C3]) after the detection of a possible axis collision (s. 70092: “Collision of two axes detected.”). It is displayed due to the internal error handling of the control, if the affected axis is part of a gantry system. | |||
Reaction | Class | 7 | Controlled stop of the gantry system | ||
Solution | Class | 6 | s. error message 70092 “Collision of two axes detected” | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number of affected gantry axis s. P-AXIS-00016 | |||||
Error type | 11, Error message from position controller. | ||||
| |||||
70265 | Geparkter Antrieb soll bewegt werden. | ||||
| Description | An axis shall be interpolated although the axis is parked by an HLI-command. See also [HLI - MCControlBoolUnitMode0]. | |||
Reaction | Class | 5 | Immediate Stopp of axis. | ||
Solution | Class | 6 | Reset “park axis” (MCControlBoolUnitMode0) signal on the HLI before interpolating axis. | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number of affected gantry axis s. P-AXIS-00016 | |||||
%2: | Actual value [-] | ||||
Actual value of state word 2 (ZSW2) of the drive. | |||||
%3: | Block number [-] | ||||
Block number in NC-program. | |||||
Error type | 11, Error message from position controller. | ||||
| |||||
70266 | Drive shall be moved although encoder is parked. | ||||
| Description | An axis shall be moved although the encoder of the axis is parked via a HLI-command. See also [HLI - MCControlBoolUnit_Mode1 ] . | |||
Reaction | Class | 5 | Immediate stop of axis. | ||
Solution | Class | 6 | Reset command park encoder ([HLI - MCControlBoolUnit_Mode1]) on the HLI before moving the axis. | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number of affected gantry axis s. P-AXIS-00016 | |||||
%2: | Block number [-] | ||||
Value of encoder state word (GX_ZSW) | |||||
%3: | Block number [-] | ||||
Block number in NC-Program. | |||||
Error type | 11, Error message from position controller. | ||||
| |||||
70267 | Timeout while reading absolute position from drive. | ||||
| Description | When requesting the absolute position from an PROFIDRIVE the value was not delivered within the timeout limit. | |||
Reaction | Class | 5 | Immediate stop of axis. | ||
Solution | Class | 6 |
| ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number of affected gantry axis s. P-AXIS-00016 | |||||
%2: | Actual value [-] | ||||
Value of encoder state word GX_ZSW. | |||||
%3: | Upper limit value [1 µsec] | ||||
Timeout limit. | |||||
Error type | - | ||||
| |||||
70268 | No actual position configured in the cyclic telegram for this operation mode. | ||||
| Description | For this axis there are no actual positions transmitted from the drive to the numerical control. However, the numerical control needs actual positions for the parameterized operation mode (e.g. position control, s. P-AXIS-00320). Solution: Correct the configuration of the cyclic telegram, in order that actual positions are transmitted from the drive. | |||
Reaction | Class | 5 | The start of the numerical control is aborted. | ||
Solution | Class | 7 | Correct the cyclic telegram configuration. | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number of affected axis s. P-AXIS-00016 | |||||
%2: | Drive type [-] | ||||
Drive type of affected axis s. P-AXIS-00020 | |||||
%3: | Actual value [-] | ||||
Parameterized operation mode s. P-AXIS-00320 | |||||
Error type | - | ||||
| |||||
70269 | No command velocity configured in the cyclic telegram for this operation mode. | ||||
| Description | The in the numerical control for this axis computed command velocity is not transmitted to the drive. However, for the parameterized operation mode (e.g. position control, s. P-AXIS-00320) the command velocity must be transmitted. Solution: Correct the configuration of the cyclic telegram, in order that the computed command velocity is transmitted to the drive. | |||
Reaction | Class | 5 | The start of the numerical control is aborted | ||
Solution | Class | 7 | Correct the configuration of the cyclic telegram | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number of affected axis s. P-AXIS-00016 | |||||
%2: | Drive type [-] | ||||
Drive type of affected axis s. P-AXIS-00020 | |||||
%3: | Actual value [-] | ||||
Parameterized operation mode s. P-AXIS-00320 | |||||
Error type | - | ||||
| |||||
70271 |
| |||
| Description | This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer. | ||
Reaction | Class | 5 |
| |
Solution | Class | 8 | Restart of NC-control necessary. | |
70272 | Invalid name for EtherCAT master process. | ||||
| Description | The specified process name of the EtherCAT master for the real-time operation system INtime is invalid (s. P-AXIS-00372). The process name is dependent of the used network interface. Valid names are:
| |||
Reaction | Class | 5 | Correct the process name P-AXIS-00372 | ||
Solution | Class | 7 | Abortion of start-up | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number of affected axis s. P-AXIS-00016 | |||||
%2: | Incorrect value [-] | ||||
Invalid process name | |||||
Error type | - | ||||
| |||||
70273 | Different names for EtherCAT master process. | ||||
| Description | The given names for the EtherCAT Master process (real-time operation system Intime) of two or more axis are different. However, at present the numerical control supports only one EtherCAT Master process. | |||
Reaction | Class | 5 | Abortion of start-up | ||
Solution | Class | 7 | Use identical process name P-AXIS-00372 for all axis | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number of affected axis s. P-AXIS-00372 | |||||
%2: | Incorrect value [-] | ||||
Specified process name s. P-AXIS-00372 | |||||
%3: | Expected value [-] | ||||
Expected process name s. P-AXIS-00372 | |||||
Error type | - | ||||
| |||||
70274 | Invalid memory identifier (memory_ident) for memory region. | ||||
| Description |
| |||
Reaction | Class | 5 |
| ||
Solution | Class | 7 |
| ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Incorrect value [-] | ||||
| |||||
Error type | - | ||||
| |||||
70275 | Timeout during execution of a #DRIVE command. | ||||
| Description | The execution of the #DRIVE command (see also [PROG]) was not acknowledged by the drive within the given time limit. | |||
Reaction | Class | 7 | Abortion of program. | ||
Solution | Class | 6 | Check in drive amplifier why command was not executed and correct cause. | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number of affected axis s. P-AXIS-00016 | |||||
%2: | Limit value [-] | ||||
Time limit. | |||||
Error type | 11, Error message from position controller. | ||||
| |||||
70276 | Invalid parameter set number at parameter set switching. | ||||
| Description | In a #DRIVE command for parameter set switching an invalid parameter set number was entered in PARAM_SET. See also [PROG]. | |||
Reaction | Class | 7 | Abortion of program. | ||
Solution | Class | 6 | Enter correct parameter set number in NC program. | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number of affected axis s. P-AXIS-00016 | |||||
%2: | Incorrect value [-] | ||||
Erroneous parameter set number from NC program. | |||||
%3: | Lower limit value [-] | ||||
Minimal admissible parameter set number. | |||||
%4: | Upper limit value [-] | ||||
Maximal admissible parameter set number. | |||||
Error type | 11, Error message from position controller. | ||||
| |||||
70277 | Invalid motor number at motor switching. | ||||
| Description | In a #DRIVE command for motor switching an invalid motor number was entered in MOTOR. See also [PROG]. | |||
Reaction | Class | 7 | Abortion of program. | ||
Solution | Class | 6 | Enter correct motor set number in NC program. | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number of affected axis s. P-AXIS-00016 | |||||
%2: | Incorrect value [-] | ||||
Erroneous motor number from NC program. | |||||
%3: | Lower limit value [-] | ||||
Minimal admissible motor number. | |||||
%4: | Upper limit value [-] | ||||
Maximal admissible motor number. | |||||
Error type | 11, Error message from position controller. | ||||
| |||||
70278 | The command #DRIVE is not supported by this drive type. | ||||
| Description | The command #DRIVE was used for an axis whose drive type does not support this command. | |||
Reaction | Class | 7 | Abortion of program. | ||
Solution | Class | 6 | Change NC program. | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number of affected axis s. P-AXIS-00016 | |||||
%2: | Logical axis number [-] | ||||
Drive type of axis, s. P-AXIS-00020. | |||||
Error type | 11, Error message from position controller. | ||||
| |||||
70279 | Programmed telegram element not found in configured telegram. | ||||
| Description | In a #DRIVE WR [] command (see also [PROG]) for element TELEGR_ELEM a telegram element name was programmed which is not configured in the cyclic nominal value telegram of the drive. | |||
Reaction | Class | 1 | Program is aborted. | ||
Solution | Class | 1 | Correct NC program and use the correct telegram element name or extend the cyclic telegram for the needed telegram element. | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number of affected axis s. P-AXIS-00016 | |||||
%2: | Actual value [-] | ||||
In #DRIVE command programmed, unknown telegram element. | |||||
%3: | Actual value [-] | ||||
| |||||
%4: | Incorrect value [-] | ||||
| |||||
Error type | - | ||||
| |||||
70280 | ISG_ERR_TXT: Value of user ident out of range. | ||||
| Description | It was tried with a #DRIVE WR [... TELEGR_ELEM=XXX VAL= ...] command to assign telegram element XXX a value which is outside the valid range for this telegram element. | |||
Reaction | Class | 7 | Abortion of program. | ||
Solution | Class | 6 | Adjust value of VAL in the NC-program. | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number of affected axis s. P-AXIS-00016 | |||||
%2: | Incorrect value [-] | ||||
In VAL-element programmed, erroneous value | |||||
%3: | Lower limit value [-] | ||||
Minimum admissible value. | |||||
%4: | Upper limit value [-] | ||||
Maximum admissible value. | |||||
Error type | 11, Error message from position controller. | ||||
| |||||
70281 |
| |||
| Description | This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer. | ||
Reaction | Class | 7 |
| |
Solution | Class | 8 | Restart of NC-control necessary. | |
70282 | Drive error during initialization of zero pulse search. | ||||
| Description | During the initialization of the zero pulse search an error in the drive occurred. Consult the documentation of the drive manufacturer for a further error diagnosis. | |||
Reaction | Class | 7 | Closed-loop controlled halt of axis | ||
Solution | Class | 6 | Consult the documentation of the drive manufacturer | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number of affected axis s. P-AXIS-00016 | |||||
%2: | Drive type [-] | ||||
Drive type of affected axis s. P-AXIS-00020 | |||||
%3: | Actual value [-] | ||||
| |||||
%4: | Block number [-] | ||||
Block number of the NC program, in which the error occurred. | |||||
Error type | 11, Error message from position controller. | ||||
| |||||
70283 | Drive error during zero pulse search. | ||||
| Description | During the zero pulse search an error in the drive occurred. Consult the documentation of the drive manufacturer for a further error diagnosis. | |||
Reaction | Class | 7 | Closed-loop controlled halt of axis | ||
Solution | Class | 6 | Consult the documentation of the drive manufacturer | ||
Parameter | %1: | Actual value [-] | |||
Logical axis number of affected axis s. P-AXIS-00016 | |||||
%2: | Drive type [-] | ||||
Drive type of affected axis s. P-AXIS-00020 | |||||
%3: | Block number [-] | ||||
Block number of the NC program, in which the error occurred. | |||||
Error type | 11, Error message from position controller. | ||||
| |||||
70284 | Calculated absolute position out of range. | ||||
| Description | The CNC computes a new absolute axis position during setting the homing position (s. [HLI] or during reading the absolute position from a profidrive. The computed result however is greater than permissible. Possible causes:
| |||
Reaction | Class | 7 | Closed-loop controlled stop of axis, setting of homing position is aborted | ||
Solution | Class | 6 |
| ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number P-AXIS-00016 of affected axis. | |||||
%2: | Actual value [Increment] | ||||
Calculated absolute position in increments. | |||||
%3: | Lower limit value [-] | ||||
Minimum permissible position value | |||||
%4: | Upper limit value [-] | ||||
Maximum permissible position value | |||||
Error type | - | ||||
| |||||
70285 | Programmierte Antriebsfunktion nicht in den konfigurierten Daten gefunden. | ||||
| Description | In a #DRIVE WR SYN [... KEY=XXX VAL= ...] command the function key XXX was not found in the configuration date of the axis. | |||
Reaction | Class | 7 | Abortion of program. | ||
Solution | Class | 6 | Adjust used function key in the NC-program or add the function key used in the NC program to the configuration data. | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number of affected axis s. P-AXIS-00016 | |||||
%2: | Actual value [-] | ||||
In KEY-element programmed, unknown value. | |||||
Error type | 11, Error message from position controller. | ||||
| |||||
70286 | Communication type not supported by drive type. | ||||
| Description | The configured communication type for the drive function is not supported for this drive type. | |||
Reaction | Class | 7 | Abortion of program. | ||
Solution | Class | 6 | Change configuration, use a communication type that is supported for this drive type. | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number of affected axis s. P-AXIS-00016 | |||||
%2: | Incorrect value [-] | ||||
Configured, not supported communication type: | |||||
0 | Cyclic communication | ||||
1 | Acyclic communication. | ||||
%3: | Actual value [-] | ||||
Function key of e drive function, for which the erroneous communication type was configured. | |||||
%4: | Drive type [-] | ||||
Drive type, see P-AXIS-00020 | |||||
Error type | - | ||||
| |||||
70287 | Different data types in parameter list and configured telegram. | ||||
| Description | The data type configured for a drive function does not fit to the data type that was configured in the cyclic telegram for the transmission of the drive function. | |||
Reaction | Class | 7 | Abortion of program. | ||
Solution | Class | 6 | Change configuration, the data type configured for the drive function must fit to the data type of the telegram element which is used for transmission of the drive function in the cyclic telegram. | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number of affected axis s. P-AXIS-00016 | |||||
%2: | Actual value [-] | ||||
Name of configured drive function with the wrong data type. | |||||
%3: | Incorrect value [-] | ||||
Data type configured in the drive function. | |||||
%4: | Actual value [-] | ||||
Data type configured in the cyclic telegram. | |||||
%5: | Incorrect value [-] | ||||
| |||||
Error type | - | ||||
| |||||
70288 | The configured data type is not supported | ||||
| Description | The data type of a configured drive function is not supported. | |||
Reaction | Class | 1 | Abortion of program. | ||
Solution | Class | 1 | Change configuration, use a communication type that is supported for this drive type. | ||
Parameter | %1: | Actual value [-] | |||
Logical axis number of affected axis s. P-AXIS-00016 | |||||
%2: | Actual value [-] | ||||
Name of the drive function | |||||
%3: | Incorrect value [-] | ||||
Data type not supported. | |||||
Error type | - | ||||
| |||||
70290 | Fehler beim Schreiben einer SERCOS-Ident aufgetreten. | ||||
| Description | An error occurred while writing a SERCOS parameter during the execution of a drive command. | |||
Reaction | Class | 5 | Abortion of program. | ||
Solution | Class | 6 | Check number and value of SERCOS parameter written. | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number of affected axis s. P-AXIS-00016 | |||||
%2: | Actual value [-] | ||||
Number of the written SERCOS parameter. | |||||
%3: | Actual value [-] | ||||
Value of the written SERCOS parameter. | |||||
%4: | Actual value [-] | ||||
Name of the drive function. | |||||
Error type | 11, Error message from position controller. | ||||
| |||||
70291 | The functionality is not supported by this drive type. | ||||
| Description | In the #DRIVE command a drive functionality was programmed which is not supported by the drive. | |||
Reaction | Class | 7 | Abortion of program. | ||
Solution | Class | 6 | Change NC program. | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number of affected axis s. P-AXIS-00016 | |||||
%2: | Incorrect value [-] | ||||
Drive type see P-AXIS-00020. | |||||
%3: | Incorrect value [-] | ||||
Unsupported drive functionality that was programmed in the #DRIVE command. | |||||
Error type | 11, Error message from position controller. | ||||
| |||||
70292 | Reference cam signal is not configured in cyclic telegram. | ||||
| Description | Parameter P-AXIS-00321 was set up to read the reference cam signal directly from the drive. However, the necessary elements to transmit the digital inputs from the drive to the control are not configured in the cyclic telegram. | |||
Reaction | Class | 5 |
| ||
Solution | Class | 1 | Configure elements for the transmission of the digital inputs in the drive’s cyclic actual values telegram. | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number of affected axis s. P-AXIS-00016 | |||||
%2: | Incorrect value [-] | ||||
Name of digital input set up in P-AXIS-00321. | |||||
%3: | Drive type [-] | ||||
Block number of the NC program, in which the error occurred. | |||||
Error type | - | ||||
| |||||
70293 | Error when starting probing command in the drive. | ||||
| Description | An error occurred in a SERCOS drive when a probing command was started. | |||
Reaction | Class | 7 |
| ||
Solution | Class | 6 | Detect the error cause in the drive by using the drive manufacturers diagnostic tools. | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number of affected axis s. P-AXIS-00016 | |||||
%2: | Actual value [-] | ||||
Return value 1 of the drive command. | |||||
%3: | Actual value [-] | ||||
Return value 1 of the drive command. | |||||
%4: | Actual value [-] | ||||
Command state. | |||||
%5: | Block number [-] | ||||
Block number. | |||||
Error type | 11, Error message from position controller. | ||||
| |||||
70294 | Correction movement was aborted. | ||||
| Description | A correction movement of an axis was aborted due to one of the following reasons:
| |||
Reaction | Class | 1 |
| ||
Solution | Class | 1 | Change PLC program resp. fieldbus configuration. | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number of affected axis s. P-AXIS-00016 | |||||
%2: | Block number [-] | ||||
Block number. | |||||
Error type | 11, Error message from position controller. | ||||
| |||||
70295 | No homing on zero pulse possible with the configured telegram. | ||||
| Description | Axis was set up for homing with zero pulse (P-AXIS-00084) but the necessary telegram elements are not configured in the cyclic drive telegram. In the drive telegram must be configured: latched zero pulse value, latch control word, latch status word. Homing on zero pulse is deactivated after output of this warning. | |||
Reaction | Class | 7 |
| ||
Solution | Class | 1 | Determine with the values 2 .. 4 of the error messages which values are missing in the drive telegram and change drive telegram accordingly. | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number of affected axis s. P-AXIS-00016 | |||||
%2: | Actual value [-] | ||||
Value is set to 1 if zero pulse value is configured in the cyclic telegram. | |||||
%3: | Actual value [-] | ||||
Value is set to 1 if latch status word is configured in the cyclic telegram. | |||||
%4: | Actual value [-] | ||||
Value is set to 1 if latch control word is configured in the cyclic telegram. | |||||
%5: | Corrected value [-] | ||||
Corrected value of P-AXIS-00084. | |||||
Error type | 11, Error message from position controller. | ||||
| |||||
70296 | The wr_ident[0] set up is not a valid SERCOS ident. | ||||
| Description | The SERCOS ident string set up in the parameter list is not a valid SERCOS parameter identifier. | |||
Reaction | Class | 7 | Abortion of program. | ||
Solution | Class | 6 | Change parameter identifier in the parameter list. Valid parameter identifiers are of the form. [S|s|P|p]-[0..7]-[1 .. 04095]. Examples: S-0-47 or P-7-3650. | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number of affected axis s. P-AXIS-00016 | |||||
%2: | Actual value [-] | ||||
Name of the drive function. | |||||
%3: | Incorrect value [-] | ||||
Set up parameter identifier. | |||||
Error type | - | ||||
| |||||
70297 | Traversing range of axis is bigger than the value range of the absolute encoder. | ||||
| Description | For a PROFIDRIVE with absolute encoder the traversing range of the axis, which is defined by the software limit switches (P-AXIS-00177/P-AXIS-00178) is bigger than the value range of the absolute encoder, which is defined by P-AXIS-00092 und P-AXIS-00336. In this case the mapping of the encoder position to the axis position is not unique. | |||
Reaction | Class | 5 | System error, reboot of control necessary | ||
Solution | Class | 7 | Correct P-AXIS-00336. The number of determinable revolutions of the absolute encoder must be taken from the drive documentation. In some cases that value can be read from the drive (P979 subindex 5). | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number of affected axis s. P-AXIS-00016 | |||||
%2: | Actual value [0.1 µm or 0,0001°] | ||||
Set up traversing range of the axis. | |||||
%3: | Actual value [0.1 µm or 0,0001°] | ||||
Maximum expressible traversing range of encoder (P-AXIS-00336 * P-AXIS-00092). | |||||
%4: | Actual value [-] | ||||
Value of P-AXIS-00336. | |||||
%5: | Actual value [Increment] | ||||
Value of P-AXIS-00092. | |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
70298 | The operation mode of the drive could not be read. | ||||
| Description | The drive-controlled homing for CANopen requires that the mode of operation in the drive is switched to mode “homing”. Before changing the mode of operation and for verifying afterwards, the active mode of operation in the drive must be read. One of these reading attempts failed however. | |||
Reaction | Class | 5 | Abortion of homing | ||
Solution | Class | 6 | Consult the documentation of the drive manufacturer | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number of affected axis s. P-AXIS-00016 | |||||
%2: | Drive type [-] | ||||
Drive type of affected axis s. P-AXIS-00020 | |||||
%3: | Block number [-] | ||||
Block number, in which the error occurred | |||||
Error type | - | ||||
| |||||
70299 | The operation mode of the drive could not be changed. | ||||
| Description | The drive-controlled homing for CANopen requires that the mode of operation in the drive is switched to homing mode. Changing the mode of operation in the drive failed however. | |||
Reaction | Class | 5 | Abortion of homing | ||
Solution | Class | 6 | Consult the documentation of the drive manufacturer | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number of affected axis s. P-AXIS-00016 | |||||
%2: | Drive type [-] | ||||
Drive type of affected axis s. P-AXIS-00020 | |||||
%3: | Block number [-] | ||||
Block number, in which the error occurred | |||||
Error type | - | ||||
| |||||
70300 | A drive error occurred during homing. | ||||
| Description | An error occurred in the CANopen drive during drive-controlled homing. Consult the documentation of the drive manufacturer for a further error diagnostics. | |||
Reaction | Class | 5 | Abrupt stop of the axis | ||
Solution | Class | 6 | Consult the documentation of the drive manufacturer | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number of affected axis s. P-AXIS-00016 | |||||
%2: | Drive type [-] | ||||
Drive type of affected axis s. P-AXIS-00020 | |||||
%3: | Actual value [-] | ||||
Status word of the drive | |||||
%4: | Block number [-] | ||||
Block number, in which the error occurred. | |||||
Error type | - | ||||
| |||||
70301 |
| |||
| Description | This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer. | ||
Reaction | Class | 5 |
| |
Solution | Class | 8 | Restart of NC-control necessary. | |
70302 | Drive controlled homing could not be terminated. | ||||
| Description | For the drive-controlled CANopen homing the operation mode of the drive must be switched to mode homing. After homing is finished, the original operation mode must be restored in the drive. If an error occurred, the reference traverse cannot be finished and the axis cannot be moved. Possible solutions:
| |||
Reaction | Class | 5 | Abrupt stop of the axis | ||
Solution | Class | 6 | Command another reset. Restart the control. | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number of affected axis s. P-AXIS-00016 | |||||
%2: | Drive type [-] | ||||
Drive type of affected axis s. P-AXIS-00020 | |||||
Error type | - | ||||
| |||||
70304 | Axis command positions inconsistent after abortion of an correction movement | ||||
| Description | A correction movement of the axis, triggered by a rising edge of drive enable, was aborted during an active program and afterwards the axis should be moved by the interpolator. If an axis correction movement is active while a program is started the target position of this movement is used a command position to initialize the axis positions of the NC channel. With the abortion of the correction movement this target position is not reached which leads to a permanent offset in the axis position. To prevent this position offset an error message is output if the axis shall be moved in this state by the interpolator. An abortion of a correction movement is triggered by:
| |||
Reaction | Class | 7 | Stop of the axis | ||
Solution | Class | 6 | Prevent abortion of the correction movement, eventually start NC program when the correction movement has ended. | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number of affected axis s. P-AXIS-00016 | |||||
%2: | Block number [-] | ||||
Actual NC block number. | |||||
Error type | 11, Error message from position controller. | ||||
| |||||
70305 | PROFIDRIVE Achse ist am Ende des Steuerungshochlaufs nicht bereit. | ||||
| Description | At startup of the CNC it is checked if the axis started up without error and if the absolute positions were read from the drive this is set up in the axis parameters. This did not happen within the given time. For PROFIDRIVEs it is checked:
| |||
Reaction | Class | 7 | Stop of the axis | ||
Solution | Class | 6 | Correct cause for the error message with the information of this error message. | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number of affected axis s. P-AXIS-00016 | |||||
%2: | Actual value [-] | ||||
Error indication. A value other than zero indicates an error in the axis. | |||||
%3: | Actual value [-] | ||||
Axis state. If the axis was set up to read the absolute position from the drive and could successfully read the position bit 0x2000 is set. | |||||
%4: | Actual value [-] | ||||
Value of P-AXIS-00315 | |||||
%5: | Actual value [-] | ||||
A value of 1 is an indication that the slave live sign is running. | |||||
Error type | - | ||||
| |||||
70306 | Unrecoverable error. Reboot of control required. | ||||
| Description | An error occurred, which can not be cleared by a reset. Reboot of the control is necessary. | |||
Reaction | Class | 5 | Stop of the axis | ||
Solution | Class | 7 | This error message is output during a reset. The underlying error condition is indicated with another error message that occurred prior to this error message. Use the first error message to clear the error and reboot the control afterwards. | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number of affected axis s. P-AXIS-00016 | |||||
%2: | Drive type [-] | ||||
Drive type, s P-AXIS-00020 | |||||
%3: | Actual value [-] | ||||
| |||||
%4: | Actual value [-] | ||||
| |||||
Error type | - | ||||
| |||||
70307 / 70308 |
| |||
| Description | This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer. | ||
Reaction | Class | 5 |
| |
Solution | Class | 8 | Restart of NC-control necessary. | |
70309 | Touch probe function in drive at start of measurement already activated. | ||||
| Description | At start of measurement the touch probe function is already activated in the drive, although it must be deactivated according to the latch control word. Therefore touch probing is not possible. Possible solutions:
| |||
Reaction | Class | 7 | Closed-loop controlled stop of axis and abortion of measurement | ||
Solution | Class | 6 | Check parameterizations of the touch probe function | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number P-AXIS-00016 of affected axis | |||||
%2: | Drive type [-] | ||||
Drive type P-AXIS-00020 of affected axis | |||||
%3: | Incorrect value [-] | ||||
Status word of touch probing | |||||
%4: | Actual value [-] | ||||
Control word of touch probing | |||||
Error type | - | ||||
| |||||
70310 | Activation of leadscrew error compensation not possible since it is not selected in axis parameter list. | ||||
| Description | The lead screw error compensation (s. [FCT-C5]) must be activated in the axis parameter list (s. P-AXIS-00175) to turn it on in the NC program. | |||
Reaction | Class | 7 | Stop of axis, lead screw error compensation remains inactive | ||
Solution | Class | 6 | Activate the lead screw error compensation (s. P-AXIS-00175) | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number P-AXIS-00016 of affected axis | |||||
%2: | Incorrect value [-] | ||||
Parameter value P-AXIS-00175 for activation of lead screw error compensation | |||||
Error type | - | ||||
| |||||
70311 | Activation of leadscrew error compensation not possible since compensation table is invalid. | ||||
| Description | The lead screw error compensation (s. [FCT-C5]) cannot be turned on, since the compensation table (s. [COMP]) is missing or it contains errors. | |||
Reaction | Class | 7 | Stop of axis, lead screw error compensation remains inactive | ||
Solution | Class | 6 | Correct the compensation table s. [COMP] | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number P-AXIS-00016 of affected axis | |||||
Error type | - | ||||
| |||||
70312 | Activation of leadscrew error compensation not possible since axis is not referenced. | ||||
| Description | The axis must be homed to turn the lead screw error compensation (s. [FCT-C5]) on. Possible solutions:
| |||
Reaction | Class | 1 | Warning, lead screw error compensation remains inactive until axis is homed | ||
Solution | Class | 1 | Homing of the axis (s. [FCT-M1]) | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number P-AXIS-00016 of affected axis | |||||
%2: | Incorrect value [-] | ||||
TRUE, if axis is homed | |||||
Error type | - | ||||
| |||||
70313 | Activation of temperature compensation not possible since it is not selected in axis parameter list | ||||
| Description | The temperature compensation (s. [FCT-C5]) must be activated in the axis parameter list (s. P-AXIS-00271) to turn it on in the NC program. | |||
Reaction | Class | 7 | Stop of axis, temperature compensation remains inactive | ||
Solution | Class | 6 | Activate the temperature compensation (s. P-AXIS-00271) | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number P-AXIS-00016 of affected axis | |||||
%2: | Incorrect value [-] | ||||
Parameter value P-AXIS-00271 for activation temperature compensation | |||||
Error type | - | ||||
| |||||
70314 | Activation of temperature compensation not possible since compensation table is invalid. | ||||
| Description | The temperature compensation (s. [FCT-C5]) cannot be turned on, since the compensation table (s. [COMP]) is missing or it contains errors. | |||
Reaction | Class | 7 | Stop of axis, temperature compensation remains inactive | ||
Solution | Class | 6 | Correct the compensation table s. [COMP] | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number P-AXIS-00016 of affected axis | |||||
Error type | - | ||||
| |||||
70315 | Activation of temperature compensation not possible since axis is not referenced. | ||||
| Description | The axis must be homed to turn the temperature compensation (s. [FCT-C5]) on. Possible solutions:
| |||
Reaction | Class | 1 | Warning, temperature compensation remains inactive until axis is homed | ||
Solution | Class | 1 | Homing of the axis (s. [FCT-M1]) | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number P-AXIS-00016 of affected axis | |||||
%2: | Incorrect value [-] | ||||
TRUE, if axis is homed | |||||
Error type | - | ||||
| |||||
70316 | Activation of cross compensation not possible since it is not selected in axis parameter list | ||||
| Description | The cross compensation (s. [FCT-C5]) must be activated in the axis parameter list (s. P-AXIS-00047) to turn it on in the NC program. | |||
Reaction | Class | 7 | Stop of axis, cross compensation remains inactive | ||
Solution | Class | 6 | Activate the cross compensation (s. P-AXIS-00047) | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number P-AXIS-00016 of affected axis | |||||
%2: | Incorrect value [-] | ||||
Parameter value P-AXIS-00047 for activation of cross compensation | |||||
Error type | - | ||||
| |||||
70317 | Activation of cross compensation not possible since compensation table is invalid. | ||||
| Description | The cross compensation (s. [FCT-C5]) cannot be turned on, since the compensation table (s. [COMP]) is missing or it contains errors. | |||
Reaction | Class | 7 | Stop of axis, cross compensation remains inactive | ||
Solution | Class | 6 | Correct the compensation table s. [COMP] | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number P-AXIS-00016 of affected axis | |||||
Error type | - | ||||
| |||||
70318 | Activation of cross compensation not possible since master axis is not referenced. | ||||
| Description | The master axis of the cross compensation (s. [FCT-C5])must be homed in order to turn the compensation on. The correction values for the slave axis are calculated in dependency of the position of the master axis. Possible solutions:
| |||
Reaction | Class | 1 | Warning, cross compensation remains inactive until master axis is homed | ||
Solution | Class | 1 | Homing of the master axis (s. [FCT-M1]) | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number P-AXIS-00016 of affected slave axis | |||||
%2: | Logical axis number [-] | ||||
Logical axis number of master axis | |||||
%3: | Incorrect value [-] | ||||
TRUE, if axis is homed | |||||
Error type | - | ||||
| |||||
70319 | Activation of plane compensation not possible since it is not selected in axis parameter list | ||||
| Description | The plane compensation (s. [FCT-C5]) must be activated in the axis parameter list (s. P-AXIS-00174) to turn it on in the NC program. | |||
Reaction | Class | 7 | Stop of axis, plane compensation remains inactive | ||
Solution | Class | 6 | Activate the plane compensation (s. P-AXIS-00174) | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number P-AXIS-00016 of affected axis | |||||
%2: | Incorrect value [-] | ||||
Parameter value P-AXIS-00174 for activation of plane compensation | |||||
Error type | - | ||||
| |||||
70320 | Activation of plane compensation not possible since compensation table is invalid. | ||||
| Description | The plane compensation (s. [FCT-C5]) cannot be turned on, since the compensation table (s. [COMP]) is missing, or it contains errors. | |||
Reaction | Class | 7 | Stop of axis, plane compensation remains inactive | ||
Solution | Class | 6 | Correct the compensation table s. [COMP] | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number P-AXIS-00016 of affected axis | |||||
Error type | - | ||||
| |||||
70321 | Activation of plane compensation not possible since master axes are not referenced. | ||||
| Description | The master axes of the plane compensation (s. [FCT-C5]) must be homed to turn the compensation on. The correction values for the slave axis are calculated in dependency of the positions of the master axes. Possible solutions:
| |||
Reaction | Class | 1 | Warning, plane compensation remains inactive until master axes are homed | ||
Solution | Class | 1 | Homing of the master axes (s. [FCT-M1]) | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number P-AXIS-00016 of affected slave axis | |||||
%2: | Logical axis number [-] | ||||
Logical axis number P-COMP-00014 of the first master axis | |||||
%3: | Actual value [-] | ||||
TRUE, if axis is homed | |||||
%4: | Logical axis number [-] | ||||
Logical axis number P-COMP-00015 of the second master axis | |||||
%5: | Actual value [-] | ||||
TRUE, if axis is homed | |||||
Error type | - | ||||
| |||||
70322 / 70323 |
| |||
| Description | This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer. | ||
Reaction | Class | 7 |
| |
Solution | Class | 8 | Restart of NC-control necessary. | |
70324 | Encoder overflow offset bigger than encoder range. | ||||
| Description | The shift of the encoder overflow (P-AXIS-00354) is bigger than the distance moved within one encoder revolution. | |||
Reaction | Class | 5 | Stop of the axis | ||
Solution | Class | 1 |
| ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number of affected axis s. P-AXIS-00016 | |||||
%2: | Incorrect value [0.1 µm or 0,0001°] | ||||
Setup value for P-AXIS-00354. | |||||
%3: | Limit value [0.1 µm or 0,0001°] | ||||
Limit value for P-AXIS-00354. | |||||
%4: | Corrected value [0.1 µm or 0,0001°] | ||||
Corrected value of P-AXIS-00354. | |||||
Error type | 6, Error message by data transfer into control device. | ||||
| |||||
70325 | Axis movement from axis compensation while feedhold. | ||||
| Description | The cross and plane compensation (s. [FCT-C5]) correct the position of the slave axis in dependency of the position(s) of the master axis (axes). The slave axis is moved by the compensation, e.g. if a master axis is moved in a different CNC channel, although feedhold (s. [HLI]) is set for the slave axis Possible solutions:
| |||
Reaction | Class | 1 | Warning | ||
Solution | Class | 1 | Remove feedhold from slave axis | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number P-AXIS-00016 of affected slave axis | |||||
%2: | Drive type [-] | ||||
Drive type of affected axis s. P-AXIS-00020 | |||||
%3: | Block number [-] | ||||
Logical axis number of moved master axis P-COMP-00005, P-COMP-00014, P-COMP-00015 | |||||
%4: | Logical axis number [-] | ||||
Block number of the NC program in the channel of the master axis, in which the error occurred. | |||||
Error type | 11, Error message from position controller. | ||||
| |||||
70326 | Timeout while drive operation mode switch. | ||||
| Description | The operation mode of a drive could not be switched within the specified time. | |||
Reaction | Class | 5 | Stop of axis | ||
Solution | Class | 6 | Use drive documentation to solve reason why mode switch was not executed. | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number for axis. | |||||
%2: | Actual value [-] | ||||
Operation mode requested from CNC | |||||
%3: | Incorrect value [-] | ||||
Actual operation mode of drive | |||||
%4: | Limit value [-] | ||||
Time limit | |||||
Error type | 11, Error message from position controller. | ||||
| |||||
70328 |
| |||
| Description | This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer. | ||
Reaction | Class | 5 | Output of this error message, the super numerous actual positions are ignored. | |
Solution | Class | 8 | Restart of NC-control necessary. | |
70329 | Sensor signal: step of actual value oversized. | ||||
| Description |
| |||
Reaction | Class | 5 |
| ||
Solution | Class | 6 |
| ||
Parameter | %1: | Actual value [0.1 µm or 0,0001°] | |||
| |||||
%2: | Limit value [0.1 µm or 0,0001°] | ||||
| |||||
%3: | Logical axis number [-] | ||||
| |||||
%4: | Drive type [-] | ||||
| |||||
%5: | Block number [-] | ||||
| |||||
Error type | - | ||||
| |||||
70330 | Sensor complete drop out. | ||||
| Description |
| |||
Reaction | Class | 5 |
| ||
Solution | Class | 6 |
| ||
Parameter | %1: | Actual value [0.1 µm or 0,0001°] | |||
| |||||
%2: | Limit value [0.1 µm or 0,0001°] | ||||
| |||||
%3: | Logical axis number [-] | ||||
| |||||
%4: | Drive type [-] | ||||
| |||||
%5: | Block number [-] | ||||
| |||||
Error type | - | ||||
| |||||
70331 | Tactile divergence oversized. | ||||
| Description |
| |||
Reaction | Class | 5 |
| ||
Solution | Class | 6 |
| ||
Parameter | %1: | Actual value [0.1 µm or 0,0001°] | |||
| |||||
%2: | Limit value [0.1 µm or 0,0001°] | ||||
| |||||
%3: | Logical axis number [-] | ||||
| |||||
%4: | Actual value [0.1 µm or 0,0001°] | ||||
| |||||
%5: | Block number [-] | ||||
| |||||
Error type | - | ||||
| |||||
70332 | Function DIST_CTRL ON at program end. | ||||
| Description |
| |||
Reaction | Class | 5 |
| ||
Solution | Class | 6 |
| ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Block number [-] | ||||
| |||||
Error type | - | ||||
| |||||
70333 | Function DIST_CTRL ON and release axis. | ||||
| Description |
| |||
Reaction | Class | 5 |
| ||
Solution | Class | 6 |
| ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Block number [-] | ||||
| |||||
Error type | - | ||||
| |||||
70334 | Function DIST_CTRL ON by actual deselection. | ||||
| Description |
| |||
Reaction | Class | 5 |
| ||
Solution | Class | 6 |
| ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Block number [-] | ||||
| |||||
Error type | - | ||||
| |||||
70335 | Function DIST_CTRL ON without SET_POS. | ||||
| Description |
| |||
Reaction | Class | 5 |
| ||
Solution | Class | 6 |
| ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Block number [-] | ||||
| |||||
Error type | - | ||||
| |||||
70336 | Function DIST_CTRL is not activated. | ||||
| Description |
| |||
Reaction | Class | 5 |
| ||
Solution | Class | 6 |
| ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Block number [-] | ||||
| |||||
Error type | - | ||||
| |||||
70337 | Time delay for disabling drive after PLC watchdog error is different for master-/slave axis. | ||||
| Description | The parameter P-AXIS-00367 specifies a time delay, after that the CNC removes the drive releases at the latest if a PLC watchdog error (s. [HLI]) occurs. The value of P-AXIS-00367 must be equal for all axes belonging to a same gantry system. | |||
Reaction | Class | 1 | Warning and correction of time delay for the slave axis | ||
Solution | Class | 1 | Correct parameter P-AXIS-00367 | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number P-AXIS-00016 of affected gantry slave axis | |||||
%2: | Logical axis number [-] | ||||
Logical axis number P-AXIS-00016 of affected gantry master axis | |||||
%3: | Incorrect value [1 µsec] | ||||
Time delay P-AXIS-00367 of slave axis | |||||
%4: | Incorrect value [1 µsec] | ||||
Time delay P-AXIS-00367 of master axis | |||||
%5: | Corrected value [1 µsec] | ||||
Corrected time delay P-AXIS-00367 for slave axis | |||||
Error type | - | ||||
| |||||
70338 | No actual position configured for input axis of axis transformation. | ||||
| Description | For an axis specific input transformation an axis was configured as auxiliary input which has no position encoder configured. | |||
Reaction | Class | 5 | Output of this error message, the output value of the transformation is set to zero and tracking is set for this axis. | ||
Solution | Class | 7 | Change configuration, auxiliary input axes are only possible for axes with an position encoder. | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number of axis with no position encoder configured. | |||||
%2: | Drive type [-] | ||||
Drive type of axis without configured position encoder. | |||||
Error type | - | ||||
| |||||
70339 | Invalid axis number configured for input axis of axis transformation. | ||||
| Description | For an axis specific input transformation an auxiliary input variable with an unknown axis number was configured. | |||
Reaction | Class | 5 | Output of this error message, the output value of the transformation is set to zero and tracking is set for this axis. | ||
Solution | Class | 7 | Change configuration | ||
Parameter | %1: | Logical axis number [-] | |||
Unknown logical axis number. | |||||
Error type | - | ||||
| |||||
70340 | An error occurred during the initialization of the axis specific transformation. | ||||
| Description | An error occurred during the initialization of the axis specific input filter. | |||
Reaction | Class | 5 | Output of this error message, the output value of the transformation is set to zero and tracking is set for this axis. | ||
Solution | Class | 7 | Change configuration. | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number of axis with input transformation. | |||||
%2: | Logical axis number [-] | ||||
Transformation id of input transformation. | |||||
Error type | - | ||||
| |||||
70341 | Homing is not supported for this kind of axis specific transformation. | ||||
| Description | An axis specific input transformation, which does not support homing, is active for this axis and homing was started. | |||
Reaction | Class | 5 | Output of this error message, abortion of program. | ||
Solution | Class | 7 |
| ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number. | |||||
Error type | - | ||||
| |||||
70342 | Axis transformation error. | ||||
| Description | An axis specific transformation was activated. The error only can occur because of missing or incomplete parameter setting of an axis specific transformation. Further information to functionality see | |||
Reaction | Class | 5 | Output of this error, program termination. | ||
Solution | Class | 6 | Check the parameter setting for the selected axis specific transformation. | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number of affected axis. | |||||
%2: | Actual value [-] | ||||
Info variable | |||||
%3: | Actual value [-] | ||||
Current selected transformation ID. | |||||
Error type | - | ||||
| |||||
70343 | For this operation mode the position lag has to be configured in the command value telegram. | ||||
| Description | An axis shall be operated position controlled in DSC-mode. For this operation mode it is necessary that the position lag is configured in the cyclic command values telegram. | |||
Reaction | Class | 5 | Output of this error message, reset is locked. | ||
Solution | Class | 7 | Add position lag to cyclic command value telegram or change operation mode of the axis. | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number (see P-AXIS-00016) | |||||
%2: | Drive type [-] | ||||
Drive type (siehe auch P-AXIS-00020). | |||||
%3: | Actual value [-] | ||||
Configured operation mode (P-AXIS-00320). | |||||
Error type | - | ||||
| |||||
70344 | For this operation mode the position controller gain has to be configured in the command value telegram. | ||||
| Description | An axis shall be operated position controlled in DSC-mode. For this operation mode it is necessary that the position controller gain is configured in the cyclic command values telegram. | |||
Reaction | Class | 5 | Output of this error message, reset is locked. | ||
Solution | Class | 7 | Add position controller gain to cyclic command value telegram or change operation mode of the axis. | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number (see P-AXIS-00016) | |||||
%2: | Drive type [-] | ||||
Drive type (P-AXIS-00020). | |||||
%3: | Actual value [-] | ||||
Configured operation mode (P-AXIS-00320). | |||||
Error type | - | ||||
| |||||
70345 | Only spindles can be operated in open position loop mode. | ||||
| Description | An axis shall be operated without closed position loop. This is only for spindles possible. See P-AXIS-00320. | |||
Reaction | Class | 5 | Output of this error message, reset is locked. | ||
Solution | Class | 7 | Change operation mode of axis (see P-AXIS-00320) and restart control. | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number (see P-AXIS-00016) | |||||
%2: | Drive type [-] | ||||
Drive type (P-AXIS-00020). | |||||
%3: | Actual value [-] | ||||
Configured operation mode (P-AXIS-00320). | |||||
%4: | Actual value [-] | ||||
Internal operation mode. | |||||
%5: | Actual value [-] | ||||
Configured axis type (See P-AXIS-00018) | |||||
Error type | - | ||||
| |||||
70346 | For this operation mode the command position must be configured in the command value telegram. | ||||
| Description | An axis shall be operated by output of command positions and position control in the drive.. For this operation mode it is necessary that the command position is configured in the cyclic command values telegram. | |||
Reaction | Class | 5 | Output of this error message, reset is locked. | ||
Solution | Class | 7 | Add command position to cyclic command value telegram or change operation mode of the axis. | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number (see P-AXIS-00016) | |||||
%2: | Drive type [-] | ||||
Drive type (see P-AXIS-00020). | |||||
%3: | Actual value [-] | ||||
Configured operation mode (see P-AXIS-00320). | |||||
Error type | - | ||||
| |||||
70347 |
| |||
| Description | This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer. | ||
Reaction | Class | 5 |
| |
Solution | Class | 8 | Restart of NC-control necessary. | |
70348 | Delay time for acceleration feedforward is bigger than cycle time. | ||||
| Description | The delay time for acceleration feedforward was set up to a value bigger than or equal to the interpolator cycle time. | |||
Reaction | Class | 1 | Output of this error message, the delay for acceleration feedforward is disabled (P-AXIS-00390 set to zero). | ||
Solution | Class | 1 | Set P-AXIS-00390 to a value less than the interpolator cycle time. | ||
Parameter | %1: | Logical axis number [-] | |||
Log. Axis number. (see P-AXIS-00016). | |||||
%2: | Actual value [1 µsec] | ||||
Erroneous value of P-AXIS-00390. | |||||
%3: | Corrected value [1 µsec] | ||||
Corrected value of P-AXIS-00390. | |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
70349 | Delay time for velocity feedforward is bigger than cycle time. | ||||
| Description | The delay time for velocity feedforward (see also P-AXIS-00389) was set up to a value bigger than or equal to the interpolator cycle time. | |||
Reaction | Class | 1 | Output of this error message, the delay for velocity feedforward is disabled (P-AXIS-00389 set to zero). | ||
Solution | Class | 1 | Set P-AXIS-00389 to a value less than the interpolator cycle time. | ||
Parameter | %1: | Logical axis number [-] | |||
Log. Axis number. (see P-AXIS-00016). | |||||
%2: | Actual value [1 µsec] | ||||
Erroneous value of P-AXIS-00389. | |||||
%3: | Corrected value [1 µsec] | ||||
Corrected value of P-AXIS-00389. | |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
70350 | Velocity feedforward with additive command value active, but none configure additive velocity command value. | ||||
| Description | In parameter P-AXIS-00223 velocity feedforward via an additive velocity command value was activated (bit 0x100 is set) but in the cyclic process data no additive velocity command value is configured. | |||
Reaction | Class | 5 | Output of this error message, velocity feedforward is disabled (bits 0x100 and 0x001 in P-AXIS-00223 are cleared). | ||
Solution | Class | 6 | Clear either Bit 0x100 in P-AXIS-00223 or configure an additive velocity command value in the cyclic process data. | ||
Parameter | %1: | Actual value [-] | |||
Log. Axis number. (see P-AXIS-00016). | |||||
%2: | Actual value [-] | ||||
Erroneous value of P-AXIS-00223. | |||||
%3: | Corrected value [-] | ||||
Corrected value of P-AXIS-00223. | |||||
Error type | - | ||||
| |||||
70351 | Acceleration feedforward with additive command value active, but none configure additive torque command value. | ||||
| Description | In parameter P-AXIS-00223 acceleration feedforward via an additive torque command value was activated (bit 0x200 is set) but in the cyclic process data no additive torque command value is configured. | |||
Reaction | Class | 5 | Output of this error message, velocity feedforward is disabled (bits 0x200 and 0x002 in P-AXIS-00223 are cleared). | ||
Solution | Class | 6 | Clear either Bit 0x200 in P-AXIS-00223 or configure an additive torque command value in the cyclic process data. | ||
Parameter | %1: | Actual value [-] | |||
Log. Axis number. (see P-AXIS-00016). | |||||
%2: | Actual value [-] | ||||
Erroneous value of P-AXIS-00223. | |||||
%3: | Corrected value [-] | ||||
Corrected value of P-AXIS-00223. | |||||
Error type | - | ||||
| |||||
70355 | Time const for balancing filter (P-AXIS_00361) is to small. | ||||
| Description | The cutoff frequency of the PT2 element defined by P-AXIS-00361 is bigger than half of the system sampling rate (1/interpolator cycle time). | |||
Reaction | Class | 7 | If this error message occurs at startup of the control P-AXIS-00361 is set to zero and so feedforward balancing disabled. If this error message occurs when an axis parameter list is updated the new, erroneous value is discarded. | ||
Solution | Class | 1 | Enter correct value of P-AXIS-00361. P-AXIS-00361 must be bigger than the value in parameter 5 of the error message. | ||
Parameter | %1: | Logical axis number [-] | |||
Log. Axis number. (see P-AXIS-00016). | |||||
%2: | Incorrect value [-] | ||||
Cutoff frequency of the balancing filter in Hertz. | |||||
%3: | Limit value [-] | ||||
Maximal allowable cutoff frequency in Hertz | |||||
%4: | Incorrect value [1 µsec] | ||||
Set up value of P-AXIS-00361. | |||||
%5: | Lower limit value [1 µsec] | ||||
Minimal allowable value of P-AXIS-00361. | |||||
Error type | - | ||||
| |||||
70356 | Command position of position controller and drive inconsistent. | ||||
| Description |
| |||
Reaction | Class | 1 |
| ||
Solution | Class | 1 |
| ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Actual value [-] | ||||
| |||||
%3: | Actual value [0.1 µm or 0,0001°] | ||||
| |||||
%4: | Actual value [0.1 µm or 0,0001°] | ||||
| |||||
%5: | Actual value [0.1 µm or 0,0001°] | ||||
| |||||
Error type | 11, Error message from position controller. | ||||
| |||||
70357 | Invalid probing channel programmed. | ||||
| Description | For a NC command “MC_TouchProbeChannel” (see also [PROG] a channel number was passed as parameter, which is outside the valid range for that parameter. | |||
Reaction | Class | 7 | Output of error message, abortion of program. | ||
Solution | Class | 6 | Use correct channel number. | ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Lower limit value [-] | ||||
| |||||
%3: | Upper limit value [-] | ||||
| |||||
%4: | Incorrect value [-] | ||||
| |||||
Error type | - | ||||
| |||||
70358 | X-axis is not programmed after the Sync-In command. | ||||
| Description |
| |||
Reaction | Class | 4 |
| ||
Solution | Class | 6 |
| ||
Parameter | %1: | Actual value [-] | |||
| |||||
%2: | Actual value [-] | ||||
| |||||
Error type | 1, Error message from NC-program. | ||||
| |||||
70359 | X-axis is not programmed after the Sync-Out command. | ||||
| Description |
| |||
Reaction | Class | 4 |
| ||
Solution | Class | 6 |
| ||
Parameter | %1: | Actual value [-] | |||
| |||||
%2: | Actual value [-] | ||||
| |||||
Error type | 1, Error message from NC-program. | ||||
| |||||
70360 |
| |||
| Description | This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer. | ||
Reaction | Class | 3 |
| |
Solution | Class | 8 | Restart of NC-control necessary. | |
70361 | Length of output process data exceeds length of configured process data. | ||||
| Description | When trying to write data in the process data of the axis the admissible length of the process data was exceeded. | |||
Reaction | Class | 7 |
| ||
Solution | Class | 6 |
| ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number P-AXIS-00016 of the axis. | |||||
%2: | Actual value [-] | ||||
Index of the erroneous data segment | |||||
%3: | Actual value [-] | ||||
Offset of the erroneous data segment | |||||
%4: | Actual value [-] | ||||
Length of the erroneous data segment | |||||
%5: | Actual value [-] | ||||
Configured process data length | |||||
Error type | - | ||||
| |||||
70362 | Attempt to write process data while axis is moving. | ||||
| Description | It was tried to write in the process data of the axis while the axis was interpolated. | |||
Reaction | Class | 7 | Closed-loop controlled stop of axis | ||
Solution | Class | 6 | Write process data when axis is in stoppage. | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number P-AXIS-00016 of the axis. | |||||
%2: | Actual value [-] | ||||
| |||||
Error type | 1, Error message from NC-program. | ||||
| |||||
70363 | Tool change with changing gear ratio only permitted in axis standstill. | ||||
| Description | The position controller executes a gear switch if a tool with a gear is changed (s. [TOOL]). Therefore, changing a tool with a gear ratio is only permitted in standstill due to security reasons. | |||
Reaction | Class | 7 | Closed-loop controlled stop of axis | ||
Solution | Class | 6 | Stop the spindle before changing the tool. | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number P-AXIS-00016 of affected axis | |||||
%2: | Actual value [-] | ||||
Interpolation end (TRUE/FALSE) | |||||
%3: | Actual value [-] | ||||
Axis in position window (TRUE/FALSE) | |||||
Error type | - | ||||
| |||||
70364 / 70365 |
| |||
| Description | This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer. | ||
Reaction | Class | 7 |
| |
Solution | Class | 8 | Restart of NC-control necessary. | |
70366 | Permissible range exceeded during tool gear change. | ||||
| Description | A tool with a gear was changed for a spindle axis (s. [TOOL, Tool Data]). However, a parameter value exceeded valid range during gear change in the position controller. | |||
Reaction | Class | 7 | Closed-loop controlled stop of axis, gear switch is aborted | ||
Solution | Class | 6 | Correct the parameter value | ||
Parameter | %1: | Upper limit value [Increment] | |||
Permissible limit | |||||
%2: | Logical axis number [-] | ||||
Logical axis number P-AXIS-00016 of affected axis. | |||||
%3: | Incorrect value [Increment] | ||||
Invalid parameter value | |||||
%4: | Corrected value [Increment] | ||||
Corrected parameter value | |||||
%5: | Actual value [Increment/0.1µm] | ||||
Path resolution of axis s. P-AXIS-00234, P-AXIS-00233 | |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
70367 | Tool change with changing gear ratio not permitted for gantry axes. | ||||
| Description | Changing a tool with a gear ratio (automatic gear change in position controller, s. [TOOL]) is not permitted for gantry axes. | |||
Reaction | Class | 7 | Closed-loop controlled stop of axis | ||
Solution | Class | 6 | Correct the NC-program | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number P-AXIS-00016 of affected axis. | |||||
%2: | Actual value [-] | ||||
Operation mode P-AXIS-00015 of affected axis. | |||||
Error type | - | ||||
| |||||
70368 | Change of movement direction only permitted in axis standstill. | ||||
| Description | The axis parameters P-AXIS-00230 and P-AXIS-00231 allow a sign reversal of the actual position or the set position/value in the position controller. The value of both parameters can be changed with a parameter update, if the operation mode P-AXIS-00015 ALLOW_RESOULTION_CHANGE = 0x00400000 is set for the axis. This is however permitted only in axis standstill due to security reasons. | |||
Reaction | Class | 7 | Closed-Loop controlled stop of axis, parameter changes are dismissed | ||
Solution | Class | 7 | Stop axis before updating the parameters P-AXIS-00230 and P-AXIS-00231. | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number P-AXIS-00016 of affected axis. | |||||
%2: | Actual value [-] | ||||
Actual value of P-AXIS-00230 sign reversal of actual value | |||||
%3: | Actual value [-] | ||||
Actual value of P-AXIS-00231 sign reversal of set value/position | |||||
%4: | Incorrect value [-] | ||||
New value for P-AXIS-00230 sign reversal of actual value | |||||
%5: | Incorrect value [-] | ||||
New value for P-AXIS-00231 sign reversal of set value/position | |||||
Error type | 11, Error message from position controller. | ||||
| |||||
70369 | Tool gear change not possible. Gear ratio not active! | ||||
| Description | This error message is a consecutive error. An update of the axis parameters was executed for a spindle axis with active tool gear (s. [TOOL]). Due to the changed parameters the tool gear could not be reactivated. The tool gear ratio is therefore no longer active. | |||
Reaction | Class | 7 | Closed-loop controlled stop of axis | ||
Solution | Class | 7 | Correct parameter error, reselect tool | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number P-AXIS-00016 of affected axis. | |||||
%2: | Actual value [-] | ||||
Active tool gear ratio s. P-TOOL-00016, P-TOOL-00017 | |||||
%3: | Actual value [-] | ||||
Reversal of rotation direction s. P-TOOL-00018 | |||||
%4: | Actual value [-] | ||||
Path resolution of axis s. P-AXIS-00234, P-AXIS-00233 | |||||
Error type | - | ||||
| |||||
70370 | Setting reference position not possible because bus does not deliver valid data. | ||||
| Description | Command for setting reference position was set via HLI (see also [HLI - Setting reference position] but the field bus does not deliver valid actual positions. Setting the reference position is not possible in this situation. | |||
Reaction | Class | 7 | Stop of axis | ||
Solution | Class | 6 | Set reference position when valid actual positions are delivered from the field bus. | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number (see P-AXIS-00016) | |||||
%2: | Actual value [-] | ||||
Flag indicates if field bus delivers valid actual positions. | |||||
Error type | - | ||||
| |||||
70371 | Restoration of axis position not possible. | ||||
| Description | The axis position could not be restored from the retain data at startup of the control. Possible reasons are:
| |||
Reaction | Class | 7 | Axis is not referenced. | ||
Solution | Class | 6 | Set axis position new. | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number P-AXIS-00016 of the axis. | |||||
%2: | Actual value [-] | ||||
Flag that indicated if retain data is valid. | |||||
Error type | - | ||||
| |||||
70372 | Shifting of reference offset for axes with power not possible. | ||||
| Description | P-AXIS-00341 was changed while the axis was enabled (see also [HLI]). | |||
Reaction | Class | 2 | Output of error message, changed value of P-AXIS-00341 is not taken over. | ||
Solution | Class | 6 | Disable axis and change P-AXIS-00341 again. | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number P-AXIS-00016 of the axis. | |||||
%2: | Actual value [0.1 µm or 0,0001°] | ||||
Actual value of P-AXIS-00341. | |||||
%3: | Incorrect value [0.1 µm or 0,0001°] | ||||
Changed value of P-AXIS-00341. | |||||
%4: | Corrected value [0.1 µm or 0,0001°] | ||||
Corrected value of P-AXIS-00341. | |||||
Error type | 3, Error message from communication. | ||||
| |||||
70373 | Configuration mode activated while drive is powered up. | ||||
| Description | Configuration mode was activated, although the axis is enabled. | |||
Reaction | Class | 7 | Output of error message, configuration mode is enabled. | ||
Solution | Class | 6 | Disable axis when configuration mode is enabled. | ||
Parameter | %1: | Logical axis number [-] | |||
Log. Axis number. (see P-AXIS-00016). | |||||
%2: | Actual value [-] | ||||
| |||||
%3: | Incorrect value [-] | ||||
| |||||
Error type | - | ||||
| |||||
70374 | Achse im Konfigurationsmodus soll interpoliert werden. | ||||
| Description | Axis shall be interpolated although it is in configuration mode. | |||
Reaction | Class | 7 | Output of error message, stop of axis | ||
Solution | Class | 6 | Exit configuration mode before interpolation the axis. | ||
Parameter | %1: | Logical axis number [-] | |||
Log. Axis number. (see P-AXIS-00016). | |||||
%2: | Actual value [-] | ||||
| |||||
Error type | - | ||||
| |||||
70375 | Inconsistent data for spindle revolution monitoring | ||||
| Description | Data for spindle tool revolution monitoring is inconsistent. For spindle tool revolution monitoring velocity limit and activation are stored inverted and noninverted. To compare these two values, the second (inverted) value is inverted again and then compared with the first value. If these two values differ this error message is output. | |||
Reaction | Class | 5 | Output of error message, stop of axis | ||
Solution | Class | 6 | Possible reasons for this error message are:
In case of an configuration error the data has to be corrected and the control restarted. In case of an transmission error the control has to be reset. | ||
Parameter | %1: | Logical axis number [-] | |||
Log. Axis number. (see P-AXIS-00016). | |||||
%2: | Actual value [1µm/sec or 0,001°/sec] | ||||
First value. | |||||
%3: | Actual value [1µm/sec or 0,001°/sec] | ||||
Second (inverted) value, inverted again, must result to same value as Kennung_2. | |||||
Error type | 11, Error message from position controller. | ||||
| |||||
70376 | Spindle revolution monitoring: Maximum permissible velocity exceeded. | ||||
| Description | The actual spindle velocity exceeds the parameterized maximum velocity for at least 10%. | |||
Reaction | Class | 5 | Output of error message, stop of axis | ||
Solution | Class | 6 | Spindle revolutions are automatically limited to the maximum velocity set up in the tool data, so this error message should never occur. If this message occurs the following reasons are possible:
| ||
Parameter | %1: | Logical axis number [-] | |||
Log. Axis number. (see P-AXIS-00016). | |||||
%2: | Actual value [1µm/sec or 0,001°/sec] | ||||
Actual axis velocity. | |||||
%3: | Upper limit value [1µm/sec or 0,001°/sec] | ||||
Maximum permissible axis velocity. | |||||
%4: | Actual value [Increment] | ||||
Actual axis velocity in increments per cycle. | |||||
Error type | 11, Error message from position controller. | ||||
| |||||
70377 | Activated value simulation with enabled Spindle revolution monitoring | ||||
| Description |
| |||
Reaction | Class | 7 |
| ||
Solution | Class | 6 |
| ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Incorrect value [-] | ||||
| |||||
Error type | 11, Error message from position controller. | ||||
| |||||
70378 | Invalid start position in axis specific active position transformation | ||||
| Description | While using the axis specific transformations P-AXIS-00380, an invalid position jump was detected. Change of solution variants with crank kinematic or wrong ACS axis position leads to a position jump. The permissible position jump can be modified with transformation parameters, the default value is 5 degrees. If the current active position difference exceeds the default or adjusted parameter this error message is generated. | |||
Reaction | Class | 5 | Movement Stop of axis | ||
Solution | Class | 6 | Correct parameters | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number P-AXIS-00016 of affected axis | |||||
%2: | Actual value [-] | ||||
Internal error code | |||||
%3: | Actual value [-] | ||||
Active transformations ID P-AXIS-00381 | |||||
%4: | Actual value [0.1 µm or 0,0001°] | ||||
MCS input coordinate of transformation | |||||
%5: | Actual value [0.1 µm or 0,0001°] | ||||
ACS output coordinate of transformation | |||||
Error type | - | ||||
| |||||
70379 | Maximum distance for zero pulse search is less than the encoder range. | ||||
| Description | The maximum distance for zero pulse search resp. search of encoder overflow set up in parameterP-AXIS-00404 is less than the distance that the axis moves in one encoder revolution. The distance moved in one encoder revolution can be defined by:
| |||
Reaction | Class | 5 | Correction of P-AXIS-00404 to the distance the axis moves while one encoder revolution, output of a warning. | ||
Solution | Class | 1 | Set up value of P-AXIS-00404 so that the axis can move while zero pulse search at least the distance of one encoder revolution. | ||
Parameter | %1: | Logical axis number [-] | |||
Axis number (P-AXIS-00016). | |||||
%2: | Actual value [0.1 µm or 0,0001°] | ||||
Distance moved within one encoder revolution. | |||||
%3: | Incorrect value [0.1 µm or 0,0001°] | ||||
Set up value of P-AXIS-00404. | |||||
%4: | Corrected value [0.1 µm or 0,0001°] | ||||
Corrected value of P-AXIS-00404. | |||||
Error type | 6, Error message by data transfer into control device. | ||||
| |||||
70380 | Maximum admissible distance for zero pulse search resp. encoder overflow search exceeded. | ||||
| Description | During homing the maximum permissible distance for zero pulse search resp. search of encoder overflow was exceeded. | |||
Reaction | Class | 7 | Stop of axis, output of error message. | ||
Solution | Class | 6 | Possible reasons for this error message are:
| ||
Parameter | %1: | Logical axis number [-] | |||
Axis number (P-AXIS-00016). | |||||
%2: | Limit value [0.1 µm or 0,0001°] | ||||
Maximum admissible distance for zero pulse search (Value of P-AXIS-00404). | |||||
%3: | Actual value [0.1 µm or 0,0001°] | ||||
Movement distance since start of zero pulse search. | |||||
%4: | Actual value [Increment] | ||||
Actual axis position in increments. | |||||
%5: | Actual value [Increment] | ||||
Axis position at start of zero pulse search in increments. | |||||
Error type | 1, Error message from NC-program. | ||||
| |||||
70381 | Request an actual position while active back interpolation. | ||||
| Description | During back interpolation of an axis after tracking actual positions where requested with the command #CHANNEL INIT [ACTPOS ...] see also [PROG, Programming]. | |||
Reaction | Class | 7 | Stop of program. | ||
Solution | Class | 6 | Change NC-program resp. PCL-program. When actual positions are requested with the command #CHANNEL INIT [ACTPOS] tracking is done internally. It is not necessary to activate tracking with the control unit MCControlBoolUnit_FollowUp (siehe auch [HLI]). | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number, see P-AXIS-00016. | |||||
%2: | Block number [-] | ||||
Block number in NC-program. | |||||
Error type | 11, Error message from position controller. | ||||
| |||||
70382 | Maximum permissible axis velocity exceeded. | ||||
| Description | The dynamic monitoring function in the position controller has detected an exceedance of the permissible axis velocity. The permissible limit can be specified in the axis parameter P-AXIS-00407. Possible solutions:
| |||
Reaction | Class | 7 | Closed-loop controlled stop of axis | ||
Solution | Class | 6 |
| ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number P-AXIS-00016 of affected axis. | |||||
%2: | Incorrect value [1µm/sec or 0,001°/sec] | ||||
Incorrect axis velocity | |||||
%3: | Upper limit value [1µm/sec or 0,001°/sec] | ||||
Maximum permissible axis velocity (P-AXIS-00407 * P-AXIS-00212) | |||||
%4: | Actual value [1µm/sec or 0,001°/sec] | ||||
Resulting axis velocity from external axis commanding (s. [HLI - Chapter External commanding of an axis]) | |||||
%5: | Actual value [1µm/sec or 0,001°/sec] | ||||
Ratio of actual to maximum permissible axis velocity P-AXIS-00212 | |||||
Error type | - | ||||
| |||||
70383 | The scaled limit value is bigger than the maximum value of the configured data type. | ||||
| Description | The scaled (see P-AXIS-00401) value of parameter P-AXIS-00409 is bigger than the maximum value of the data type set up with parameter P-AXIS-00399. | |||
Reaction | Class | 1 | Output of a warning, P-AXIS-00409 is automatically limited to the maximum value according to P-AXIS-00399. | ||
Solution | Class | 1 | Adjust P-AXIS-00409. | ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Actual value [-] | ||||
Value of P-AXIS-00396 for identification of drive function. | |||||
%3: | Incorrect value [-] | ||||
Set up value of P-AXIS-00409. | |||||
%4: | Actual value [-] | ||||
Scaling factor (see P-AXIS-00401). | |||||
%5: | Limit value [-] | ||||
Maximal possible value for P-AXIS-00409 according to the values of P-AXIS-00399 and P-AXIS-00401, also corrected value. | |||||
Error type | - | ||||
| |||||
70384 | The scaled limit value is smaller than the minimum value of the configured data type. | ||||
| Description | The scaled (see P-AXIS-00401) value of parameter P-AXIS-00408 is less than the minimum value of the data type set up with parameter P-AXIS-00399. | |||
Reaction | Class | 1 | Output of a warning, P-AXIS-00408 is automatically limited to the minimum value according to P-AXIS-00399. | ||
Solution | Class | 1 | Adjust P-AXIS-00408. | ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Actual value [-] | ||||
Value of P-AXIS-00396 for identification of drive function. | |||||
%3: | Incorrect value [-] | ||||
Set up value of P-AXIS-00408. | |||||
%4: | Actual value [-] | ||||
Scaling factor (see P-AXIS-00401). | |||||
%5: | Limit value [-] | ||||
Minimal possible value for P-AXIS-00408 according to the values of P-AXIS-00399 and P-AXIS-00401, also corrected value. | |||||
Error type | - | ||||
| |||||
70385 | The configured maximum value is less than the configured minimum value. | ||||
| Description | The set up minimum value (P-AXIS-00408) is bigger than the set up maximum value (P-AXIS-00409). | |||
Reaction | Class | 1 | Output of a warning, P-AXIS-00408 and P-AXIS-00409 are swapped. | ||
Solution | Class | 1 | Adjust P-AXIS-00408 and P-AXIS-00409. | ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Actual value [-] | ||||
Value of P-AXIS-00396 for identification of drive function. | |||||
%3: | Upper limit value [-] | ||||
Set up value of P-AXIS-00408. | |||||
%4: | Lower limit value [-] | ||||
Set up value of P-AXIS-00409. | |||||
Error type | - | ||||
| |||||
70386 | Usage of DC brake is only for spindles possible. | ||||
| Description | Parameter P-AXIS-00410 was set to a value not equal to 1 (DC brake control was enabled), although the axis is not a spindle. | |||
Reaction | Class | 1 | Output off warning, P-AXIS-00410 is set to -1. | ||
Solution | Class | 1 | Use of a DC brake is only possible for spindles. Deactivate DC brake by setting P-AXIS-00410 to 1. | ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Actual value [-] | ||||
Configured axis type, see P-AXIS-00018. | |||||
%3: | Incorrect value [-] | ||||
Configured value of P-AXIS-00410. | |||||
%4: | Corrected value [-] | ||||
Corrected value of P-AXIS-00410. | |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
70387 | Invalid bit number for control at DC-brake. | ||||
| Description | Parameter P-AXIS-00410 was assigned an invalid value. | |||
Reaction | Class | 1 | Output of warning, P-AXIS-00410 is set to -1 (DC brake control is disabled): | ||
Solution | Class | 1 |
| ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Incorrect value [-] | ||||
Erroneous value of P-AXIS-00410: | |||||
%3: | Corrected value [-] | ||||
Corrected value of P-AXIS-00410. | |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
70388 | DC-brake control is not supported for this drive type. | ||||
| Description | DC brake control was activated (P-AXIS-00410 was assigned a value not equal to -1), although the configured drive type does not support control of a DC brake. | |||
Reaction | Class | 1 | Output of warning, P-AXIS-00410 is set to -1 (DC brake control is disabled): | ||
Solution | Class | 1 | Set P-AXIS-00410 to 1. | ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Actual value [-] | ||||
Configured drive type (see P-AXIS-00020). | |||||
%3: | Incorrect value [-] | ||||
Erroneous value of P-AXIS-00410. | |||||
%4: | Corrected value [-] | ||||
Corrected value of P-AXIS-00410. | |||||
Error type | 2, Error message by data transfer from parameter list into control device. | ||||
| |||||
70389 | Axis reference due to bus failure removed. Position monitoring functions (e.g. software limit switch) not active! | ||||
| Description | The maximum permissible telegram failures (s. P-AXIS-00409) on the EtherCAT-fieldbus were exceeded. Axis without an absolute measurement system (s. P-AXIS-00014) will be marked as not referenced, since position information may be lost due to the bus failure. The position monitoring functions like software limit switch (s. [FCT-A2, Software limit switches]) or Gantry-monitoring (s. [FCT-C11, Gantry operation]) are deactivated for this axis. Possible solutions:
| |||
Reaction | Class | 7 | Closed-loop controlled stop of axis | ||
Solution | Class | 6 | Restart homing of the axis e.g. with NC-command G74 | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number P-AXIS-00016 of affected axis | |||||
%2: | Drive type [-] | ||||
Drive type P-AXIS-00020 of affected axis | |||||
%3: | Actual value [-] | ||||
Last homing state of axis (TRUE = axis is homed) | |||||
%4: | Corrected value [-] | ||||
Homing state after bus failure (FALSE = axis is not homed) | |||||
%5: | Actual value [-] | ||||
Value of bus failure counter | |||||
Error type | 11, Error message from position controller. | ||||
| |||||
70390 | Changing measuring input for drive probing not possible for this drive type. | ||||
| Description |
| |||
Reaction | Class | 7 |
| ||
Solution | Class | 6 |
| ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Drive type [-] | ||||
| |||||
%3: | Actual value [-] | ||||
| |||||
%4: | Incorrect value [-] | ||||
| |||||
%5: | Corrected value [-] | ||||
| |||||
Error type | 11, Error message from position controller. | ||||
| |||||
70391 | Changing measuring edge for drive probing not possible for this drive type. | ||||
| Description |
| |||
Reaction | Class | 7 |
| ||
Solution | Class | 6 |
| ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Drive type [-] | ||||
| |||||
%3: | Actual value [-] | ||||
| |||||
%4: | Incorrect value [-] | ||||
| |||||
%5: | Corrected value [-] | ||||
| |||||
Error type | 11, Error message from position controller. | ||||
| |||||
70392 | Changing measuring parameters for external measuring signals (mess_signal_achs_steuer) not possible. | ||||
| Description |
| |||
Reaction | Class | 7 |
| ||
Solution | Class | 6 |
| ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Incorrect value [-] | ||||
| |||||
%3: | Actual value [-] | ||||
| |||||
%4: | Actual value [-] | ||||
| |||||
%5: | Actual value [-] | ||||
| |||||
Error type | 11, Error message from position controller. | ||||
| |||||
70393 |
| |||
| Description | This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer. | ||
Reaction | Class | 7 |
| |
Solution | Class | 8 | Restart of NC-control necessary. | |
70394 | Maximum admissible distance for homing exceeded. | ||||
| Description | During homing the distance between the start position of homing and the actual axis command position has exceeded the value set up in parameter P-AXIS-00412. This is an indication that the homing sequence is disturbed, e. g. the reference cam was not found. | |||
Reaction | Class | 7 | Abortion of program, output of error message. | ||
Solution | Class | 6 | Fix reason for disturbance of homing. | ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Limit value [0.1 µm or 0,0001°] | ||||
Set up value for P-AXIS-00412. | |||||
%3: | Incorrect value [0.1 µm or 0,0001°] | ||||
Distance from start position of homing. | |||||
%4: | Actual value [Increment] | ||||
Actual command value. | |||||
%5: | Actual value [0.1 µm or 0,0001°] | ||||
Modulo range of the axis. | |||||
Error type | 1, Error message from NC-program. | ||||
| |||||
70395 | Life sign error profibus slave | ||||
| Description |
| |||
Reaction | Class | 1 |
| ||
Solution | Class | 1 |
| ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Actual value [-] | ||||
| |||||
%3: | Actual value [-] | ||||
| |||||
%4: | Upper limit value [-] | ||||
| |||||
Error type | - | ||||
| |||||
70396 | Denominator of axis coupling factor is zero. | ||||
| Description | A axis coupling was set up over the HLI, with the value zero in the denominator for the fraction oft the coupling factor, see also [HLI]. | |||
Reaction | Class | 7 | Output of error message, axis coupling is not activated. | ||
Solution | Class | 6 |
| ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number | |||||
%2: | Actual value [-] | ||||
Index of the erroneous coupling definition on the HLI, starting with 1. | |||||
%3: | Actual value [-] | ||||
Numerator of coupling factor fraction. | |||||
%4: | Incorrect value [-] | ||||
Denominator of coupling factor fraction, erroneous value. | |||||
Error type | - | ||||
| |||||
70397 | Coupling factor for the axis is bigger than the permissible maximum value. | ||||
| Description | At activation of axis coupling via the HLI a coupling factor bigger than the maximal permissible coupling factor was set. | |||
Reaction | Class | 7 | Output of error message, axis coupling is not activated. | ||
Solution | Class | 6 |
| ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number | |||||
%2: | Actual value [-] | ||||
Index of the erroneous coupling definition on the HLI, starting with 1. | |||||
%3: | Limit value [-] | ||||
Numerator of coupling factor fraction. | |||||
%4: | Incorrect value [-] | ||||
Denominator of coupling factor fraction. | |||||
%5: | Incorrect value [-] | ||||
| |||||
Error type | - | ||||
| |||||
70398 |
| |||
| Description | This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer. | ||
Reaction | Class | 3 |
| |
Solution | Class | 8 | Restart of NC-control necessary. | |
70399 | Invalid transition for distance control. | ||||
| Description |
| |||
Reaction | Class | 7 |
| ||
Solution | Class | 6 |
| ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Block number [-] | ||||
| |||||
Error type | - | ||||
| |||||
70400 | Axis lost its reference. | ||||
| Description | During active reference monitoring the bitwise AND-conjunction of the input data configured with P-AXIS-00426 and the check mask set up with P-AXIS-00425 results in the value zero. This means the axis has lost its reference. | |||
Reaction | Class | 7 | Output of error message, stop of axis. | ||
Solution | Class | 6 | Claer cause for reference loss and reference axis again. Possible causes for reference loss are:
| ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Incorrect value [-] | ||||
Value of reference signal delivered from drive (Value of process data set up in P-AXIS-00426). | |||||
%3: | Actual value [-] | ||||
Checkmark calculated from P-AXIS-00425. | |||||
Error type | - | ||||
| |||||
70401 | Ident for axis reference test not configured in cyclic input process data. | ||||
| Description | During active reference monitoring the bitwise AND-conjunction of the input data configured with P-AXIS-00426 and the check mask set up with P-AXIS-00425 results in the value zero. This means the axis has lost its reference. | |||
Reaction | Class | 5 | Output of error message, stop of axis. | ||
Solution | Class | 1 | Claer cause for reference loss and reference axis again. Possible causes for reference loss are:
| ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Incorrect value [-] | ||||
Value of reference signal delivered from drive (Value of process data set up in P-AXIS-00426). | |||||
Error type | - | ||||
| |||||
70402 | Setting/resetting of bits is not supported for this communication type. | ||||
| Description | The data type set up in P-AXIS-00399 is either “BITARRAY_16” or “BITARRAY_32” although the communication type set up in P-AXIS-00397 does not support bitwise writing of drive values. | |||
Reaction | Class | 7 | Output of error message, evaluation of drive functions is aborted. | ||
Solution | Class | 6 | Change either P-AXIS-00399 or P-AXIS-00397. | ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Actual value [-] | ||||
Name of configured drive function (P-AXIS-00396). | |||||
%3: | Drive type [-] | ||||
Drive type (P-AXIS-00020). | |||||
%4: | Incorrect value [-] | ||||
Configured communication type (P-AXIS-00397). | |||||
%5: | Incorrect value [-] | ||||
Configured data type (P-AXIS-00399). | |||||
Error type | - | ||||
| |||||
70403 | The configured bitmask is to big for the configured data type. | ||||
| Description | The bit mask set up in P-AXIS-00429 is bigger than the maximum value of the data type set up in P-AXIS-00399. | |||
Reaction | Class | 7 | Output of error message, evaluation of drive functions is aborted. | ||
Solution | Class | 6 | Adjust value of P-AXIS-00429. | ||
Parameter | %1: | Actual value [-] | |||
| |||||
%2: | Actual value [-] | ||||
Name of configured drive function (P-AXIS-00396). | |||||
%3: | Incorrect value [-] | ||||
Configured value of P-AXIS-00429 | |||||
%4: | Actual value [-] | ||||
Configured data type (P-AXIS-00399). | |||||
%5: | Incorrect value [-] | ||||
Permissible maximum value of P-AXIS-00429. | |||||
Error type | - | ||||
| |||||
70404 | Configured bitmask contains bits, that are used also from the CNC. | ||||
| Description | The bit mask set up in P-AXIS-00429 is bigger than the maximum value of the data type set up in P-AXIS-00399. | |||
Reaction | Class | 7 | Output of error message, evaluation of drive functions is aborted. | ||
Solution | Class | 6 | Adjust value of P-AXIS-00429. | ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Actual value [-] | ||||
Name of configured drive function (P-AXIS-00396). | |||||
%3: | Actual value [-] | ||||
Configured value of P-AXIS-00429 | |||||
%4: | Actual value [-] | ||||
Configured data type (P-AXIS-00399). | |||||
%5: | Incorrect value [-] | ||||
Permissible maximum value of P-AXIS-00429. | |||||
Error type | - | ||||
| |||||
70405 | The telegram element configured for the #DRIVE command is used exclusively from the CNC. | ||||
| Description | The telegram element configured for bitwise writing (P-AXIS-00398) is used exclusively by the CNC. | |||
Reaction | Class | 1 | Output of error message, evaluation of drive functions is aborted. | ||
Solution | Class | 1 | Adjust value of P-AXIS-00398. | ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Actual value [-] | ||||
Name of configured drive function (P-AXIS-00396). | |||||
%3: | Incorrect value [-] | ||||
Configured value of P-AXIS-00398. | |||||
Error type | - | ||||
| |||||
70406 | Number of configured user idents exceeds limit. | ||||
| Description | During the configuration of drive functions (see [FCT-A10]) the number of configured elements in the cyclic process data that shall be written, exceeded the maximum limit | |||
Reaction | Class | 7 | Abortion of program. | ||
Solution | Class | 6 | Adjust value of VAL in the NC-program. | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number of affected axis s. P-AXIS-00016 | |||||
%2: | Drive type [-] | ||||
Drive type (P-AXIS-00020). | |||||
%3: | Limit value [-] | ||||
Actual value. | |||||
%4: | Limit value [-] | ||||
Maximum admissible value. | |||||
%5: | Actual value [-] | ||||
Name of drive function where the exceedance occurred. | |||||
Error type | - | ||||
| |||||
70407 | Position offset can not be altered after CRC error. | ||||
| Description |
| |||
Reaction | Class | 7 |
| ||
Solution | Class | 7 |
| ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Actual value [0.1 µm or 0,0001°] | ||||
| |||||
%3: | Incorrect value [-] | ||||
| |||||
Error type | - | ||||
| |||||
70408 | Invalid checksum for absolute position offset. | |||
| Description |
| ||
Reaction | Class | 7 |
| |
Solution | Class | 7 |
| |
Error type | - | |||
| ||||
70409 | Invalid checksum for absolute position offset: (Error not resettable) | ||||
| Description |
| |||
Reaction | Class | 7 |
| ||
Solution | Class | 7 |
| ||
Parameter | %1: | Logical axis number [-] | |||
| |||||
%2: | Incorrect value [0.1 µm or 0,0001°] | ||||
| |||||
%3: | Incorrect value [-] | ||||
| |||||
%4: | Incorrect value [-] | ||||
| |||||
Error type | - | ||||
| |||||
70410 | Target axis is its own source axis, calculation of command position is not possible. | ||||
| Description | At the activation of an axis coupling via the HLI (see [FCT-A9, Axis couplings via HLI]) it was detected, that parameter P-AXIS-00436 was set for the axis, and the axis is via other active axis couplings where P-AXIS-00436 is also set for the respective axis, linked to itself as a source axis. In such coupling loops it is not always possible to map the drive position clear without ambiguity to the interpolator position, so that such coupling loops are prohibited. | |||
Reaction | Class | 7 | Output of error message, axis coupling is not activated. | ||
Solution | Class | 6 | Either break coupling loop by changing the axis coupling or set for at least one axis of the coupling loop parameter P-AXIS-00436 to zero. | ||
Parameter | %1: | Logical axis number [-] | |||
Axis number of axis for which the coupling loop was detected. | |||||
%2: | Logical axis number [-] | ||||
Axis number of the axis that closes the coupling loop. | |||||
%3: | Logical axis number [-] | ||||
| |||||
Error type | - | ||||
| |||||
70411 | Filter of additional command values interface could not be generated. | ||||
| Description | For the additive command value interface, it is possible to activate a PT2-filter to smooth the command values (s. [HLI - External commanding of an axis], P-AXIS-00438). However, the generation of the filter with the actual filter time constant P-AXIS-00438 is not possible. The detailed error information can be found in the previous error message. | |||
Reaction | Class | 3 | Filter is deactivated | ||
Solution | Class | 6 | Change the time constant P-AXIS-00438 of the PT2-filter | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number P-AXIS-00016 of affected axis | |||||
%2: | Drive type [-] | ||||
Drive type of affected axis s. P-AXIS-00020 | |||||
%3: | Actual value [1 µsec] | ||||
Time constant P-AXIS-00438 of the used PT2-filter | |||||
%4: | Incorrect value [-] | ||||
| |||||
Error type | - | ||||
| |||||
70412 - 70419 |
| |||
| Description | This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer. | ||
Reaction | Class | 3 |
| |
Solution | Class | 8 | Restart of NC-control necessary. | |
70420 | Characteristic filter frequency greater than half of sample frequency. | |||
| Description | According to the sampling theorem of Shannon, the cut-off frequency can be at the maximum (½*TA = Cycle time of numerical control). The cut-off frequency of the PT2-filter is calculated from the time constant as follows: fc = 1 / (2 * PI * P-AXIS-00438). Possible solutions:
| ||
Reaction | Class | 3 | Filter is deactivated. | |
Solution | Class | 6 | Increase the time constant P-AXIS-00438 of the PT2-filter | |
Error type | - | |||
| ||||
70421 | Filter design with given parameters not possible. | |||
| Description | Not all filter parameters lead to a stable filter e.g. due to the limited computational accuracy. Possible solutions are: - Try different time constants P-AXIS-00428 for the PT2-filter - Change the cycle time of the CNC | ||
Reaction | Class | 3 | Filter is deactivated | |
Solution | Class | 6 | Change filter parameters | |
Error type | - | |||
| ||||
70422 |
| |||
| Description | This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer. | ||
Reaction | Class | 3 |
| |
Solution | Class | 8 | Restart of NC-control necessary. | |
70423 | Stability reserve of designed filter not sufficient. | |||
| Description | Not all filter parameters lead to a stable filter e.g. due to the limited computational accuracy. Possible solutions are:
| ||
Reaction | Class | 3 | Filter is deactivated | |
Solution | Class | 6 | Change filter parameters | |
Error type | - | |||
| ||||
70424 |
| |||
| Description | This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer. | ||
Reaction | Class | 3 |
| |
Solution | Class | 8 | Restart of NC-control necessary. | |
70425 | Timeout after deactivation of additive command value interface. Filter not within position window. | ||||
| Description | For the additive command value interface it is possible to activate a PT2-filter to smooth the command values (s. [HLI - External commanding of an axis], P-AXIS-00438). Due to the filter, the axis stop is little delayed, if the interface is disabled. The CNC generates this warning message, if the axis is not in standstill within a certain amount of time. | |||
Reaction | Class | 1 | Display of a warning message | ||
Solution | Class | 1 | Reduce the filter time constant P-AXIS-00438 | ||
Parameter | %1: | Logical axis number [-] | |||
Logical axis number P-AXIS-00016 of affected axis | |||||
%2: | Upper limit value [1 µsec] | ||||
Elapsed time after the deactivation of the additive command value interface | |||||
%3: | Upper limit value [-] | ||||
Elapsed CNC cycles after the deactivation of the additive command value interface | |||||
%4: | Actual value [0.1 µm or 0,0001°] | ||||
Position difference: filter output filter input | |||||
%5: | Actual value [-] | ||||
Time constant P-AXIS-00438 of the used PT2-filter | |||||
Error type | 11, Error message from position controller. | ||||
| |||||