ID-range 70250-70499

70250

Invalid resolution of master axis for cross compensation.

 

Description

The correction values for cross compensation(s. [FCT-C5 - Cross compensation])were specified in increments in the corresponding compensation data list (s. [COMP]). Increments are only allowed for path resolutions of the measuring system of one (s. P-AXIS-00234, P-AXIS-00233). However, the master axis (the axis, which position influences the slave axis) uses a different path resolutions than one.

Solution:

- Change parameter P-COMP-00003 in the compensation data list to one and specify the correction values in 0.1 µm (metrical).

Reaction

Class

3

Warning, compensation is turned off for the slave axis

Solution

Class

1

Adjust parameter P-COMP-00003 and the compensation values

Parameter

%1:

Logical axis number [-]

Logical axis number of the slave axis s. P-AXIS-00016

%2:

Logical axis number [-]

Logical axis number of affected master axis s. P-AXIS-00016, P-COMP-00005

%3:

Incorrect value [-]

Path resolution of the measuring system of the master axis s. P-AXIS-00233, P-AXIS-00234

%4:

Expected value [Increment]

Expected path resolution of the measuring system s. P-AXIS-00233, P-AXIS-00234

Error type

11, Error message from position controller.

 

70251

Invalid resolution of master axis for plane compensation.

 

Description

The correction values for plane compensation(s. [FCT-C5 - Plane compensation])were specified in increments in the corresponding compensation data list (s. [COMP]). Increments are only allowed for path resolutions of the measuring system of one (s. P-AXIS-00234, P-AXIS-00233). However, one of the master axes (the axes, which position influences the slave axis) uses a different path resolutions than one.

Solution:

- Change parameter P-COMP-00008 in the compensation data list to one and specify the correction values in 0.1 µm (metrical).

Reaction

Class

3

Warning, compensation is turned off for the slave axis

Solution

Class

1

Adjust parameter P-COMP-00008 and the compensation values

Parameter

%1:

Logical axis number [-]

Logical axis number of affected slave axis s. P-AXIS-00016

%2:

Logical axis number [-]

Logical axis number of affected master axis s. P-AXIS-00016, P-COMP-00014, P-COMP-00015

%3:

Incorrect value [-]

Path resolution of the measuring system of the master axis s. P-AXIS-00233, P-AXIS-00234

%4:

Expected value [Increment]

Expected path resolution of the measuring system s. P-AXIS-00233, P-AXIS-00234

Error type

11, Error message from position controller.

 

70252

Counter axis can not be commanded with command values.

 

Description

An axis that is configured as counter axis only was commanded to do a motion.

Reaction

Class

5

Immediate axis stop

Solution

Class

6

Do reset. Check motion command respectively configuration setting for this axis.

Parameter

%1:

Logical axis number [-]

Logical axis number P-AXIS-00016 of the axis.

%2:

Drive type [-]

Drive type P-AXIS-00020

%3:

Actual value [-]

BF LR command bit field

%4:

Block number [-]

Block number of the NC program respectively instruction number, in which the error occurred.

Error type

11, Error message from position controller.

 

70253

Active program in channel: Switch on/off of axis compensation is delayed.

 

Description

An axis compensation was turned on or off during actualising the axis parameters. Therefore it is necessary to modify the command and actual positions in the position controller for this axis. Since there is program executed in the NC channel, the compensation is turned on or off at program end in order to prevent an interfering with the program. See parameters:

- P-AXIS-00175 for lead screw error compensation

- P-AXIS-00047 for cross compensation

- P-AXIS-00174 for plane compensation

Reaction

Class

1

Warning, activation or deactivation of compensation for the affected axis is delayed until program end.

Solution

Class

1

 

Parameter

%1:

Logical axis number [-]

Logical axis number of affected slave axis s. P-AXIS-00016

%2:

Actual value [-]

State of axis compensation before actualising the axis parameters

(0 = inactive, 1 = active)

%3:

Actual value [-]

State of axis compensation after actualising the axis parameters

(0 = inactive, 1 = active)

Error type

11, Error message from position controller.

 

70254

Axis is to be compensated, although the required drive releases are missing.

 

Description

One or more axis compensations (s. [FCT-C5]) are active for the affected axis. Its position is to be corrected, since the position of one master axis has changed. However, the axis cannot move, since the required drive releases are missing.

Reaction

Class

7

Controlled stop of the affected axis.

Solution

Class

5

Set drive releases or turn axis compensation(s) off

Parameter

%1:

Logical axis number [-]

Logical axis number of affected slave axis s. P-AXIS-00016

%2:

Drive type [-]

Drive type of affected axis s. P-AXIS-00020

%3:

Block number [-]

Logical axis number of moved master axis P-COMP-00005, P-COMP-00014, P-COMP-00015

%4:

Logical axis number [-]

Block number of the NC program in the channel of the master axis, in which the error occurred.

Error type

11, Error message from position controller.

 

70255

Axis is to be compensated, but a movement of the drive is not possible.

 

Description

One or more axis compensations (s. [FCT-C5]) are active for the affected axis. Its position has to be corrected, since the position of one master axis has changed. However, the axis cannot move, since an axis-specific or channel-specific feedhold is set for the axis by the PLC.

Reaction

Class

7

Controlled stop of the affected axis.

Solution

Class

5

Remove feedhold or turn axis compensation(s) off

Parameter

%1:

Logical axis number [-]

Logical axis number of affected slave axis s. P-AXIS-00016

%2:

Drive type [-]

Drive type of affected axis s. P-AXIS-00020

%3:

Block number [-]

Logical axis number of moved master axis P-COMP-00005, P-COMP-00014, P-COMP-00015

%4:

Logical axis number [-]

Block number of the NC program in the channel of the master axis, in which the error occurred.

Error type

11, Error message from position controller.

 

70256

Number of cycles for smooth coupling/decoupling of plane comp. exceeds max limit.

 

Description

The given number of filter cycles (s. P-COMP-00027) in the compensation data list (s. [COMP - Plane compensation]) is greater than the maximum permissible cycles. The filter is used in the plane compensation (s. [FCT-C5 - Plane compensation]) for driving out the compensation value in several position controller cycles. The number of filter cycles is reduced to the maximum permissible value.

Reaction

Class

1

Warning, reduction of filter cycles on maximum permissible value.

Solution

Class

1

Reduce the filter cycles in the axis compensation list s. P-COMP-00027

Parameter

%1:

Logical axis number [-]

Logical axis number of affected slave axis s. P-AXIS-00016

%2:

Actual value [-]

Number of filter cycles given in the compensation data list s. P-COMP-00027

%3:

Corrected value [-]

Number of maximum permissible filter cycles

%4:

Block number [-]

Block number of the NC program, in which the error occurred.

Error type

11, Error message from position controller.

 

70259

Coefficient (gradient) of temperature compensation exceeds valid range.

 

Description

The temperature compensation (s. [FCT-C5]) uses a linear straight line to approximate the correction values. The gradient of the straight line is given in the parameter P-AXIS-00274 in dependency of temperature. Alternatively it can be written over a direct ADS access to the task GEO (port 551, TEMPC::coefficient IGrp = 0x20300 IOffs = 0x10043). The actual value of gradient however is not within valid range.

Reaction

Class

1

Warning, automatic correction of gradient to maximum or minimum permissible value.

Solution

Class

1

Correct value for gradient (via ADS or by actualising the axis parameter list).

Parameter

%1:

Logical axis number [-]

Logical axis number of affected axis (s. P-AXIS-00016)

%2:

Incorrect value [-]

Incorrect value of P-AXIS-00274

%3:

Limit value [-]

Maximum permissible value for gradient P-AXIS-00274

%4:

Limit value [-]

Minimum permissible value for gradient P-AXIS-00274

%5:

Corrected value [-]

Corrected value for parameter P-AXIS-00274

Error type

11, Error message from position controller.

 

70261

Terminal signals error.

 

Description

In the status byte delivered from an intelligent bus terminal the error indication is set. With this flag an internal error in the bus terminal is indicated.

Reaction

Class

8

Output of error message, stopp of axis.

Solution

Class

6

Correct error condition in the bus terminal. Further information about the error cause might be seen on LED’s directly at the bus terminal or might be read out with diagnosis software from the terminal. Look at manufacturer documentation.

Parameter

%1:

Actual value [-]

Logical axis number of affected axis (s. P-AXIS-00016)

%2:

Actual value [-]

String indicating the terminal type, e. g. “KL2541”.

%3:

Actual value [-]

Status value from the terminal that caused the error.

Error type

-

 

70262

No position encoder configured for this axis.

 

Description

In the cyclic telegram of the actual values of the axis no actual position is configured. Only spindles can be operated without position sensors.

Reaction

Class

5

Output of error message, stopp of axis.

Solution

Class

7

If the axis is no spindle axis configure an actual positioning the cyclic telgram. If axis is a spindle set parameter P-AXIS-00018 to 4.

Parameter

%1:

Logical axis number [-]

Logical axis number of affected axis (s. P-AXIS-00016)

%2:

Incorrect value [-]

Configured axis type (P-AXIS-00018).

%3:

Logical axis number [-]

 

Error type

-

 

70263

Homing method (homing_type) of master-/slave axis is different.

 

Description

Entry P-AXIS-00299 has for master- and slaveaxis of different values.

Reaction

Class

1

Output of error message, P-AXIS-00299 of the slave axis is set to the value of the master axis..

Solution

Class

1

Assign the same value for P-AXIS-00299 of master and slave axis.

Parameter

%1:

Logical axis number [-]

Logical axis number of slave axis (P-AXIS-00016).

%2:

Logical axis number [-]

Logical axis number of master axis (P-AXIS-00016).

%3:

Incorrect value [-]

Entry for P-AXIS-00299 for slave axis.

%4:

Incorrect value [-]

Entry for P-AXIS-00299 for master axis.

%5:

Corrected value [-]

Corrected value of P-AXIS-00299 for slave axis.

Error type

-

 

70264

An axis collision was detected for an axis of a GANTRY system.

 

Description

This is a subsequent error message of the collision monitoring function (s. [FCT-C3]) after the detection of a possible axis collision (s. 70092: „Collision of two axes detected.“). It is displayed due to the internal error handling of the control, if the affected axis is part of a gantry system.

Reaction

Class

7

Controlled stop of the gantry system

Solution

Class

6

s. error message 70092 „Collision of two axes detected”

Parameter

%1:

Logical axis number [-]

Logical axis number of affected gantry axis s. P-AXIS-00016

Error type

11, Error message from position controller.

 

70265

Geparkter Antrieb soll bewegt werden.

 

Description

An axis shall be interpolated although the axis is parked by an HLI-command. See also [HLI - MCControlBoolUnitMode0].

Reaction

Class

5

Immediate Stopp of axis.

Solution

Class

6

Reset ‘park axis’ (MCControlBoolUnitMode0) signal on the HLI before interpolating axis.

Parameter

%1:

Logical axis number [-]

Logical axis number of affected gantry axis s. P-AXIS-00016

%2:

Actual value [-]

Actual value of state word 2 (ZSW2) of the drive.

%3:

Block number [-]

Block number in NC-program.

Error type

11, Error message from position controller.

 

70266

Drive shall be moved although encoder is parked.

 

Description

An axis shall be moved although the encoder of the axis is parked via a HLI-command. See also [HLI - MCControlBoolUnit_Mode1 ] .

Reaction

Class

5

Immediate stopp of axis.

Solution

Class

6

Reset command ‘park encoder’ ([HLI - MCControlBoolUnit_Mode1]) on the HLI before moving the axis.

Parameter

%1:

Logical axis number [-]

Logical axis number of affected gantry axis s. P-AXIS-00016

%2:

Block number [-]

Value of encoder state word (GX_ZSW)

%3:

Block number [-]

Block number in NC-Program.

Error type

11, Error message from position controller.

 

70267

Timeout while reading absolute position from drive.

 

Description

When requesting the absolute position from an PROFIDRIVE the value was not delivered within the timeout limit.

Reaction

Class

5

Immediate stopp of axis.

Solution

Class

6

  • Consult drive documentation
  • Check drive parameters
  • Is the drive able to deliever absolute positions?

Parameter

%1:

Logical axis number [-]

Logical axis number of affected gantry axis s. P-AXIS-00016

%2:

Actual value [-]

Value of encoder state word GX_ZSW.

%3:

Upper limit value [1 µsec]

Timeoutlimit.

Error type

-

 

70268

No actual position configured in the cyclic telegramm for this operation mode.

 

Description

For this axis there are no actual positions transmitted from the drive to the numerical control. However, the numerical control needs actual positions for the parameterized operation mode (e.g. position control, s. P-AXIS-00320).

Solution:

Correct the configuration of the cyclic telegram, in order that actual positions are transmitted from the drive.

Reaction

Class

5

The start of the numerical control is aborted.

Solution

Class

7

Correct the cyclic telegram configuration.

Parameter

%1:

Logical axis number [-]

Logical axis number of affected axis s. P-AXIS-00016

%2:

Drive type [-]

Drive type of affected axis s. P-AXIS-00020

%3:

Actual value [-]

Parameterized operation mode s. P-AXIS-00320

Error type

-

 

70269

No command velocity configured in the cyclic telegram for this operation mode.

 

Description

The in the numerical control for this axis computed command velocity is not transmitted to the drive. However, for the parameterized operation mode (e.g. position control, s. P-AXIS-00320) the command velocity must be transmitted.

Solution:

Correct the configuration of the cyclic telegram, in order that the computed command velocity is transmitted to the drive.

Reaction

Class

5

The start of the numerical control is aborted

Solution

Class

7

Correct the configuration of the cyclic telegram

Parameter

%1:

Logical axis number [-]

Logical axis number of affected axis s. P-AXIS-00016

%2:

Drive type [-]

Drive type of affected axis s. P-AXIS-00020

%3:

Actual value [-]

Parameterized operation mode s. P-AXIS-00320

Error type

-

 

70271

 

 

Description

This error message informs about internal states, error solutions and the place of error in the source.Please give the complete error message data to the CNC manufacturer.

Reaction

Class

5

 

Solution

Class

8

Restart of NC-control necessary.

70272

Invalid name for EtherCAT master process.

 

Description

The specified process name of the EtherCAT master for the real-time operation system INtime is invalid (s. P-AXIS-00372). The process name is dependent of the used network interface. Valid names are:

- ECMeth0: EtherCAT Master uses network device „eth0“

- ECMeth1: EtherCAT Master uses network device „eth1“

Reaction

Class

5

Correct the process name P-AXIS-00372

Solution

Class

7

Abortion of start-up

Parameter

%1:

Logical axis number [-]

Logical axis number of affected axis s. P-AXIS-00016

%2:

Incorrect value [-]

Invalid process name

Error type

-

 

70273

Different names for EtherCAT master process.

 

Description

The given names for the EtherCAT Master process (real-time operation system Intime) of two or more axis are different. However at present the numerical control supports only one EtherCAT Master process.

Reaction

Class

5

Abortion of start-up

Solution

Class

7

Use identical process name P-AXIS-00372 for all axis

Parameter

%1:

Logical axis number [-]

Logical axis number of affected axis s. P-AXIS-00372

%2:

Incorrect value [-]

Specified process name s. P-AXIS-00372

%3:

Expected value [-]

Expected process name s. P-AXIS-00372

Error type

-

 

70274

Invalid memory identifier (memory_ident) for memory region.

 

Description

 

Reaction

Class

5

 

Solution

Class

7

 

Parameter

%1:

Logical axis number [-]

 

%2:

Incorrect value [-]

 

Error type

-

 

70275

Timeout during execution of a #DRIVE command.

 

Description

The execution of the #DRIVE command (see also [PROG]) was not acknowledged by the drive within the given time limit.

Reaction

Class

7

Abortion of program.

Solution

Class

6

Check in drive amplifier why command was not executed and correct cause.

Parameter

%1:

Logical axis number [-]

Logical axis number of affected axis s. P-AXIS-00016

%2:

Limit value [-]

Time limit.

Error type

11, Error message from position controller.

 

70276

Invalid parameter set number at parameter set switching.

 

Description

In a #DRIVE command for parameter set switching an invalid parameter set number was entered in PARAM_SET. See also [PROG].

Reaction

Class

7

Abortion of program.

Solution

Class

6

Enter correct parameter set number in NC program.

Parameter

%1:

Logical axis number [-]

Logical axis number of affected axis s. P-AXIS-00016

%2:

Incorrect value [-]

Erroneous parameter set number from NC program.

%3:

Lower limit value [-]

Minimal admissible parameter set number.

%4:

Upper limit value [-]

Maximal admissible parameter set number.

Error type

11, Error message from position controller.

 

70277

Invalid motor number at motor switching.

 

Description

In a #DRIVE command for motor switching an invalid motor number was entered in MOTOR. See also [PROG].

Reaction

Class

7

Abortion of program.

Solution

Class

6

Enter correct motor set number in NC program.

Parameter

%1:

Logical axis number [-]

Logical axis number of affected axis s. P-AXIS-00016

%2:

Incorrect value [-]

Erroneousmotornumber from NC program.

%3:

Lower limit value [-]

Minimal admissiblemotornumber.

%4:

Upper limit value [-]

Maximal admissiblemotornumber.

Error type

11, Error message from position controller.

 

70278

The command #DRIVE is not supported by this drive type.

 

Description

The command #DRIVE was used for an axis whose drive type does not support this command.

Reaction

Class

7

Abortion of program.

Solution

Class

6

Change NC program.

Parameter

%1:

Logical axis number [-]

Logical axis number of affected axis s. P-AXIS-00016

%2:

Logical axis number [-]

Drive type of axis, s. P-AXIS-00020.

Error type

11, Error message from position controller.

 

70279

Programmed telegram element not found in configured telegram.

 

Description

In a #DRIVE WR [] command (see also [PROG]) for element TELEGR_ELEM a telegram element name was programmed which is not configured in the cyclic nominal value telegram of the drive.

Reaction

Class

1

Program is aborted.

Solution

Class

1

Correct NC program and use the correct telegram element name or extend the cyclich telegram for the needed telegram element.

Parameter

%1:

Logical axis number [-]

Logical axis number of affected axis s. P-AXIS-00016

%2:

Actual value [-]

In #DRIVE command programmed, unknown telegram element.

%3:

Actual value [-]

 

%4:

Incorrect value [-]

 

Error type

-

 

70280

ISG_ERR_TXT: Value of user ident out of range.

 

Description

It was tried with a #DRIVE WR [... TELEGR_ELEM=XXX VAL= ...] command to assign telegram element XXX a value which is outside the valid range for this telegram element.

Reaction

Class

7

Abortion of program.

Solution

Class

6

Adjust value of VAL in the NC-program.

Parameter

%1:

Logical axis number [-]

Logical axis number of affected axis s. P-AXIS-00016

%2:

Incorrect value [-]

In VAL-element programmed, erroneous value

%3:

Lower limit value [-]

Minimum admissible value.

%4:

Upper limit value [-]

Maximum admissible value.

Error type

11, Error message from position controller.

 

70281

 

 

Description

This error message informs about internal states, error solutions and the place of error in the source.Please give the complete error message data to the CNC manufacturer.

Reaction

Class

7

 

Solution

Class

8

Restart of NC-control necessary.

70282

Drive error during initialization of zero pulse search.

 

Description

During the initialization of the zero pulse search an error in the drive occurred. Consult the documentation of the drive manufacturer for a further error diagnosis.

Reaction

Class

7

Closed-loop controlled halt of axis

Solution

Class

6

Consult the documentation of the drive manufacturer

Parameter

%1:

Logical axis number [-]

Logical axis number of affected axis s. P-AXIS-00016

%2:

Drive type [-]

Drive type of affected axis s. P-AXIS-00020

%3:

Actual value [-]

 

%4:

Block number [-]

Block number of the NC program, in which the error occurred.

Error type

11, Error message from position controller.

 

70283

Drive error during zero pulse search.

 

Description

During the zero pulse search an error in the drive occured.Consult the documentation of the drive manufacturer for a further error diagnosis.

Reaction

Class

7

Closed-loop controlled halt of axis

Solution

Class

6

Consult the documentation of the drive manufacturer

Parameter

%1:

Actual value [-]

Logical axis number of affected axis s. P-AXIS-00016

%2:

Drive type [-]

Drive type of affected axis s. P-AXIS-00020

%3:

Block number [-]

Block number of the NC program, in which the error occurred.

Error type

11, Error message from position controller.

 

70284

Calculated absolute position out of range.

 

Description

The CNC computes a new absolute axis position during setting the homing position (s. [HLI] or during reading the absolute position from a profidrive. The computed result however is greater than permissible.

Possible causes:

- The path resolution of the axis is greater one. The homing position given in the PLC (s. [HLI]) converted to increments is greater/smaller than permissible.

- The modus OFFSET (s. P-AXIS-00278) for setting the homing position is used. The actual position of the drive + the given offset to the homing position P-AXIS-00279 is greater/smaller than permissible.

- The absolute position read from the profidrive is greater or smaller than permissible. Maybe the conversion factor P-AXIS-00065 is wrong.

Reaction

Class

7

Closed-loop controlled stop of axis, setting of homing position is aborted

Solution

Class

6

 

Parameter

%1:

Logical axis number [-]

Logical axis number P-AXIS-00016 of affected axis.

%2:

Actual value [Increment]

Calculated absolute position in increments.

%3:

Lower limit value [-]

Minimum permissible position value

%4:

Upper limit value [-]

Maximumpermissibleposition value

Error type

-

 

70285

Programmierte Antriebsfunktion nicht in den konfigurierten Daten gefunden.

 

Description

In a #DRIVE WR SYN [... KEY=XXX VAL= ...] command the function key XXX was not found in the configuration date of the axis.

Reaction

Class

7

Abortion of program.

Solution

Class

6

Adjust used functionkey in the NC-program or add the function key used in the NC program to the configuration data.

Parameter

%1:

Logical axis number [-]

Logical axis number of affected axis s. P-AXIS-00016

%2:

Actual value [-]

In KEY-element programmed, unknown value.

Error type

11, Error message from position controller.

 

70286

Communication type not supported by drive type.

 

Description

The configured communication type for the drive function is not supported for this drive type.

Reaction

Class

7

Abortion of program.

Solution

Class

6

Change configuration, use a communication type that is supported for this drive type.

Parameter

%1:

Logical axis number [-]

Logical axis number of affected axis s. P-AXIS-00016

%2:

Incorrect value [-]

Cnfigured, not supported communication type:

0

Cyclic communication

1

Acyclic communication.

%3:

Actual value [-]

Function key of e drive function, for which the erroneous communication type was configured.

%4:

Drive type [-]

Drive type, see P-AXIS-00020

Error type

-

 

70287

Different data types in parameter list and configured telegram.

 

Description

The data type configured for a drive function does not fit to the data type that was configured in the cyclic telegram for the transmission of the drive function.

Reaction

Class

7

Abortion of program.

Solution

Class

6

Change configuration, the data type configured for the drive function must fit to the data type of the telegram element which is used for ransmission of the drive function in the cyclic telegram.

Parameter

%1:

Logical axis number [-]

Logical axis number of affected axis s. P-AXIS-00016

%2:

Actual value [-]

Name of configured drive function with the wrong data type.

%3:

Incorrect value [-]

Data type configured in the drive function.

%4:

Actual value [-]

Data type configured in the cyclic telegram.

%5:

Incorrect value [-]

 

Error type

-

 

70288

Der konfigurierte Datentyp wird nicht unterstützt.

 

Description

The data type of a configured drive function is not supported.

Reaction

Class

1

Abortion of program.

Solution

Class

1

Change configuration, use a communication type that is supported for this drive type.

Parameter

%1:

Actual value [-]

Logical axis number of affected axis s. P-AXIS-00016

%2:

Actual value [-]

Name of the drive function

%3:

Incorrect value [-]

Data type not supported.

Error type

-

 

70290

Fehler beim Schreiben einer SERCOS-Ident aufgetreten.

 

Description

An error occurred while writing a SERCOS parameter during the executuion of a drive command.

Reaction

Class

5

Abortion of program.

Solution

Class

6

Check number and value of SERCOS parameter written.

Parameter

%1:

Logical axis number [-]

Logical axis number of affected axis s. P-AXIS-00016

%2:

Actual value [-]

Number of the written SERCOS parameter.

%3:

Actual value [-]

Value of the written SERCOS parameter.

%4:

Actual value [-]

Name of the drive function.

Error type

11, Error message from position controller.

 

70291

The fuctionality is not suupported by this drive type.

 

Description

In the #DRIVE command a drive functionality was programmed which is not supported by the drive.

Reaction

Class

7

Abortion of program.

Solution

Class

6

Change NC program.

Parameter

%1:

Logical axis number [-]

Logical axis number of affected axis s. P-AXIS-00016

%2:

Incorrect value [-]

Drive type see P-AXIS-00020.

%3:

Incorrect value [-]

Unsupported drive functionaliy that was programmed in the #DRIVE command.

Error type

11, Error message from position controller.

 

70292

Reference cam signal is not configured in cyclic telegram.

 

Description

Parameter P-AXIS-00321 was set up to read the reference cam signal directly from the drive. However the necessary elements to transmit the digital inputs from the drive to the control are not configured in the cyclic telegram.

Reaction

Class

5

 

Solution

Class

1

Configure elements for the transmission of the digital inputs in the drives cyclic actual values telegram.

Parameter

%1:

Logical axis number [-]

Logical axis number of affected axis s. P-AXIS-00016

%2:

Incorrect value [-]

Name od digital input set up in P-AXIS-00321.

%3:

Drive type [-]

Block number of the NC program, in which the error occurred.

Error type

-

 

70293

Error when starting probing command in the drive.

 

Description

An error occurred in a SERCOS drive when a probing command was started.

Reaction

Class

7

 

Solution

Class

6

Detect the error cause in the drive by using the drive manufacturers diagnostic tools.

Parameter

%1:

Logical axis number [-]

Logical axis number of affected axis s. P-AXIS-00016

%2:

Actual value [-]

Return value 1 of the drive command.

%3:

Actual value [-]

Return value 1 of the drive command.

%4:

Actual value [-]

Command state.

%5:

Block number [-]

Block number.

Error type

11, Error message from position controller.

 

70294

Correction movement was aborted.

 

Description

A correction movement of an axis was aborted due to one of the following reasons:

  • The signal MCControlBoolUnit_FollowUp (see [HLI - Control cammands of an axis]) was set by the PLC.
  • The signal MCControlBoolUnit_ReleaseFeedhold z (see [HLI - Control commands of an axis]) was reset by the PLC.
  • The field bus did not deliver valid values.

Reaction

Class

1

 

Solution

Class

1

Change PLC program resp. fieldbus configuration.

Parameter

%1:

Logical axis number [-]

Logical axis number of affected axis s. P-AXIS-00016

%2:

Block number [-]

Block number.

Error type

11, Error message from position controller.

 

70295

No homing on zero pulse possible with the configured telegram.

 

Description

Axis was set up for homing with zero pulse (P-AXIS-00084) but the necessary telegram elements are not configured in the cyclic drive telegram. In the drive telegram must be configured: latched zero pulse value, latch control word, latch status word.

Homing on zero pulse is deactivated after output of this warning.

Reaction

Class

7

 

Solution

Class

1

Determine with the values 2 .. 4 of the error message which values are missing in the drive telegram and change drive telegram accordingly.

Parameter

%1:

Logical axis number [-]

Logical axis number of affected axis s. P-AXIS-00016

%2:

Actual value [-]

Value is set to 1 if zero pulse value is configured in the cyclic telegram.

%3:

Actual value [-]

Value is set to 1 if latch status word is configured in the cyclic telegram.

%4:

Actual value [-]

Value is set to 1 if latch control word is configured in the cyclic telegram.

%5:

Corrected value [-]

Corrected value of P-AXIS-00084.

Error type

11, Error message from position controller.

 

70296

The wr_ident[0] set up is not a valid SERCOS ident.

 

Description

The SERCOS ident string set up in the parameter list is not a valid SERCOS parameter identifier.

Reaction

Class

7

Abortion of program.

Solution

Class

6

Change parameter identifier in the parameter list. Valid parameter identifiers are of the form.

[S|s|P|p]-[0..7]-[1 .. 04095].

Examples:

S-0-47 or P-7-3650.

Parameter

%1:

Logical axis number [-]

Logical axis number of affected axis s. P-AXIS-00016

%2:

Actual value [-]

Name of the drive function.

%3:

Incorrect value [-]

Set up parameter identifier.

Error type

-

 

70297

Traversing range of axis is bigger than the value range of the absolute encoder.

 

Description

For a PROFIDRIVE with absolute encoder the traversing range of the axis, which is defined by the software limit switches (P-AXIS-00177/P-AXIS-00178) is bigger than the value range of the absolute encoder, which is defined by P-AXIS-00092 und P-AXIS-00336.

In this case the mapping of the encoder position to the axis position is not unique.

Reaction

Class

5

System error, reboot of control necessary

Solution

Class

7

Corect P-AXIS-00336. The number of determinable revolutions of the absolute encoder has to be taken from the drive documentation. In some cases that value can be read from the drive (P979 subindex 5).

Parameter

%1:

Logical axis number [-]

Logical axis number of affected axis s. P-AXIS-00016

%2:

Actual value [0.1 µm or 0,0001°]

Set up traversing range of the axis.

%3:

Actual value [0.1 µm or 0,0001°]

Maximum expressable traversing range of encoder (P-AXIS-00336 * P-AXIS-00092).

%4:

Actual value [-]

Value of P-AXIS-00336.

%5:

Actual value [Increment]

Value of P-AXIS-00092.

Error type

2, Error message by data transfer from parameter list into control device.

 

70298

The operation mode of the drive could not be read.

 

Description

The drive-controlled homing for CANopen requires that the mode of operation in the drive is switched to mode “homing”. Before changing the mode of operation and for verifying afterwards, the active mode of operation in the drive must be read. One of these reading attempts failed however.

Reaction

Class

5

Abortion of homing

Solution

Class

6

Consult the documentation of the drive manufacturer

Parameter

%1:

Logical axis number [-]

Logical axis number of affected axis s. P-AXIS-00016

%2:

Drive type [-]

Drive type of affected axis s. P-AXIS-00020

%3:

Block number [-]

Block number, in which the error occurred

Error type

-

 

70299

The operation mode of the drive could not be changed.

 

Description

The drive-controlled homing for CANopen requires that the mode of operation in the drive is switched to “homing” mode. Changing the mode of operation in the drive failed however.

Reaction

Class

5

Abortion of homing

Solution

Class

6

Consult the documentation of the drive manufacturer

Parameter

%1:

Logical axis number [-]

Logical axis number of affected axis s. P-AXIS-00016

%2:

Drive type [-]

Drive type of affected axis s. P-AXIS-00020

%3:

Block number [-]

Block number, in which the error occurred

Error type

-

 

70300

A drive error occured during homing.

 

Description

An error occurred in the CANopen drive during drive-controlled homing. Consult the documentation of the drive manufacturer for a further error diagnostics.

Reaction

Class

5

Abrupt stop of the axis

Solution

Class

6

Consult the documentation of the drive manufacturer

Parameter

%1:

Logical axis number [-]

Logical axis number of affected axis s. P-AXIS-00016

%2:

Drive type [-]

Drive type of affected axis s. P-AXIS-00020

%3:

Actual value [-]

Status word of the drive

%4:

Block number [-]

Block number, in which the error occurred.

Error type

-

 

70301

 

 

Description

This error message informs about internal states, error solutions and the place of error in the source.Please give the complete error message data to the CNC manufacturer.

Reaction

Class

5

 

Solution

Class

8

Restart of NC-control necessary.

70302

Drive controlled homing could not be terminated.

 

Description

For the drive-controlled CANopen homing the operation mode of the drive must be switched to mode “homing”. After homing is finished, the original operation mode must be restored in the drive. If an error occurred, the reference traverse cannot be finished and the axis cannot be moved.

Possible solutions:

- Command another reset. The control retries to restore the original operation mode in the drive.

- Restart the control. Verify that the correct mode of operation is active in the drive afterwards!

- Consult the documentation of the drive manufacturer.

Reaction

Class

5

Abrupt stop of the axis

Solution

Class

6

Command another reset. Restart the control.

Parameter

%1:

Logical axis number [-]

Logical axis number of affected axis s. P-AXIS-00016

%2:

Drive type [-]

Drive type of affected axis s. P-AXIS-00020

Error type

-

 

70304

Axis command positions inconsistent after abortion of an correction movement

 

Description

A correctionmovement of the axis, triggered by a rising edge of drive enable, was aborted during an active program and afterwards the axis should be moved by the interpolator.

If an axis correction movement is active while a program is started the target position of this movement is used a command position in order to initialize the axis positions of the NC channel. With the abortion of the correction movement this target position is not reached which leads to a permanent offset in the axis position.

To prevent this position offset an error message is output if the axis shall be moved in this state by the interpolator.

An abortion of a correction movoement is triggered by:

  • Activationof follup by the PLC (pAC[axis_idx]^.addr^.McControlLr_Data.MCControlBoolUnit_FollowUp, see also [HLI]).
  • Resetting of feed enable for the axis by the PLC (pAC[axis_idx]^.addr^.McControlLr_Data.MCControlBoolUnit_ReleaseFeedhold, see also [HLI]).

Reaction

Class

7

Stop of the axis

Solution

Class

6

Prevent abortion of the correction movement, eventually start NC program when the correction movement has ended.

Parameter

%1:

Logical axis number [-]

Logical axis number of affected axis s. P-AXIS-00016

%2:

Block number [-]

Actual NC block number.

Error type

11, Error message from position controller.

 

70305

PROFIDRIVE Achse ist am Ende des Steuerungshochlaufs nicht bereit.

 

Description

At startup of the CNC it is checked if the axis started up without error and if the absolute positions were read from the drive this is set up in the axis parameters.

This did not happen within the given time.

For PROFIDRIVEs it is checked:

  • Axis is not in error state
  • Slave live sign is counting
  • Absolute psoitionwas read from the drive if P-AXIS-00315 is set

Reaction

Class

7

Stop of the axis

Solution

Class

6

Correct cause for the error message with the information of this error message.

Parameter

%1:

Logical axis number [-]

Logical axis number of affected axis s. P-AXIS-00016

%2:

Actual value [-]

Error indication. A value other than zero indicates an error in the axis.

%3:

Actual value [-]

Axis state. If the axis was set up to read the absolute position from the drive and could successfully read the position bit 0x2000 is set.

%4:

Actual value [-]

Value of P-AXIS-00315

%5:

Actual value [-]

A value of 1 is an indication that the slave live sign is running.

Error type

-

 

70306

Unrecoverable error. Reboot of control required.

 

Description

An error occurred, which can not be cleared by a reset. Reboot of the control is necessary.

Reaction

Class

5

Stop of the axis

Solution

Class

7

This error message is output during a reset. The underlying error condition is indicated with another error message that occored prior to this error message. Use the first error message to clear the error and rebotot the control afterwards.

Parameter

%1:

Logical axis number [-]

Logical axis number of affected axis s. P-AXIS-00016

%2:

Drive type [-]

Drive type, s P-AXIS-00020

%3:

Actual value [-]

 

%4:

Actual value [-]

 

Error type

-

 

70307 / 70308

 

 

Description

This error message informs about internal states, error solutions and the place of error in the source.Please give the complete error message data to the CNC manufacturer.

Reaction

Class

5

 

Solution

Class

8

Restart of NC-control necessary.

70309

Touch probe function in drive at start of measurement already activated.

 

Description

At start of measurement the touch probe function is already activated in the drive, although it must be deactivated according to the latch control word. Therefore touch probing is not possible.

Possible solutions:

- Check the control and status word of the touch probe function

- Check theparameterizationof the touch probe function in the drive

Reaction

Class

7

Closed-loop controlled stop of axis and abortion of measurement

Solution

Class

6

Check parameterizations of the touch probe function

Parameter

%1:

Logical axis number [-]

Logical axis number P-AXIS-00016 of affected axis

%2:

Drive type [-]

Drive type P-AXIS-00020 of affected axis

%3:

Incorrect value [-]

Status word of touch probing

%4:

Actual value [-]

Control word of touch probing

Error type

-

 

70310

Activation of leadscrew error compensation not possible since it is not selected in axis parameter list.

 

Description

The lead screw error compensation (s. [FCT-C5]) must be activated in the axis parameter list (s. P-AXIS-00175) in order to turn it on in the NC program.

Reaction

Class

7

Stop of axis, lead screw error compensation remains inactive

Solution

Class

6

Activate the lead screw error compensation (s. P-AXIS-00175)

Parameter

%1:

Logical axis number [-]

Logical axis number P-AXIS-00016 of affected axis

%2:

Incorrect value [-]

Parameter value P-AXIS-00175 for activation of lead screw error compensation

Error type

-

 

70311

Activation of leadscrew error compensation not possible since compensation table is invalid.

 

Description

The lead screw error compensation (s. [FCT-C5]) cannot be turned on, since the compensation table (s. [COMP]) is missing or it contains errors.

Reaction

Class

7

Stop of axis, lead screw error compensation remains inactive

Solution

Class

6

Correct the compensation table s. [COMP]

Parameter

%1:

Logical axis number [-]

Logical axis number P-AXIS-00016 of affected axis

Error type

-

 

70312

Activation of leadscrew error compensation not possible since axis is not referenced.

 

Description

The axis must be homed in order to turn the lead screw error compensation(s. [FCT-C5]) on.

Possible solutions:

- Homing of the axis (s. [FCT-M1])

- If a absolute measuring system is used, the parameter P-AXIS-00014 can be set to 1 so that no homing of the axis is required.

Reaction

Class

1

Warning, lead screw error compensation remains inactive until axis is homed

Solution

Class

1

Homing of the axis (s. [FCT-M1])

Parameter

%1:

Logical axis number [-]

Logical axis number P-AXIS-00016 of affected axis

%2:

Incorrect value [-]

TRUE, if axis is homed

Error type

-

 

70313

Activation of temperature compensation not possible since it is not selected in axis parameter list

 

Description

The temperature compensation (s. [FCT-C5]) must be activated in the axis parameter list (s. P-AXIS-00271) in order to turn it on in the NC program.

Reaction

Class

7

Stop of axis, temperature compensation remains inactive

Solution

Class

6

Activate the temperature compensation (s. P-AXIS-00271)

Parameter

%1:

Logical axis number [-]

Logical axis number P-AXIS-00016 of affected axis

%2:

Incorrect value [-]

Parameter value P-AXIS-00271 for activation temperature compensation

Error type

-

 

70314

Activation of temperature compensation not possible since compensation table is invalid.

 

Description

The temperature compensation (s. [FCT-C5]) cannot be turned on, since the compensation table (s. [COMP]) is missing or it contains errors.

Reaction

Class

7

Stop of axis, temperature compensation remains inactive

Solution

Class

6

Correct the compensation table s. [COMP]

Parameter

%1:

Logical axis number [-]

Logical axis number P-AXIS-00016 of affected axis

Error type

-

 

70315

Activation of temperature compensation not possible since axis is not referenced.

 

Description

The axis must be homed in order to turn the temperature compensation(s. [FCT-C5]) on.

Possible solutions:

- Homing of the axis (s. [FCT-M1])

- If an absolute path measuring system is used, the parameter P-AXIS-00014 can be set to 1 so that no homing of the axis is necessary.

Reaction

Class

1

Warning, temperature compensation remains inactive until axis is homed

Solution

Class

1

Homing of the axis (s. [FCT-M1])

Parameter

%1:

Logical axis number [-]

Logical axis number P-AXIS-00016 of affected axis

%2:

Incorrect value [-]

TRUE, if axis is homed

Error type

-

 

70316

Activation of cross compensation not possible since it is not selected in axis parameter list

 

Description

The cross compensation (s. [FCT-C5]) must be activated in the axis parameter list (s. P-AXIS-00047) in order to turn it on in the NC program.

Reaction

Class

7

Stop of axis, cross compensation remains inactive

Solution

Class

6

Activate the cross compensation (s. P-AXIS-00047)

Parameter

%1:

Logical axis number [-]

Logical axis number P-AXIS-00016 of affected axis

%2:

Incorrect value [-]

Parameter value P-AXIS-00047 for activation of cross compensation

Error type

-

 

70317

Activation of cross compensation not possible since compensation table is invalid.

 

Description

The cross compensation (s. [FCT-C5]) cannot be turned on, since the compensation table (s. [COMP]) is missing or it contains errors.

Reaction

Class

7

Stop of axis, cross compensation remains inactive

Solution

Class

6

Correct the compensation table s. [COMP]

Parameter

%1:

Logical axis number [-]

Logical axis number P-AXIS-00016 of affected axis

Error type

-

 

70318

Activation of cross compensation not possible since master axis is not referenced.

 

Description

The master axis of the cross compensation(s. [FCT-C5])must be homed in order to turn the compensation on. The correction values for the slave axis are calculated in dependcy of the position of the master axis.

Possible solutions:

- Homing of the master axis (s. [FCT-M1])

- If the master axis uses an absolute path measuring system, the parameter P-AXIS-00014 can be set to 1 for the master axis so that no homing of this axis is necessary.

Reaction

Class

1

Warning, cross compensation remains inactive until master axis is homed

Solution

Class

1

Homing of the master axis (s. [FCT-M1])

Parameter

%1:

Logical axis number [-]

Logical axis number P-AXIS-00016 of affected slave axis

%2:

Logical axis number [-]

Logical axis numberof master axis

%3:

Incorrect value [-]

TRUE, if axis is homed

Error type

-

 

70319

Activation of plane compensation not possible since it is not selected in axis parameter list

 

Description

The plane compensation (s. [FCT-C5]) must be activated in the axis parameter list (s. P-AXIS-00174) in order to turn it on in the NC program.

Reaction

Class

7

Stop of axis, plane compensation remains inactive

Solution

Class

6

Activate the plane compensation (s. P-AXIS-00174)

Parameter

%1:

Logical axis number [-]

Logical axis number P-AXIS-00016 of affected axis

%2:

Incorrect value [-]

Parameter value P-AXIS-00174 for activation of plane compensation

Error type

-

 

70320

Activation of plane compensation not possible since compensation table is invalid.

 

Description

The plane compensation (s. [FCT-C5]) cannot be turned on, since the compensation table (s. [COMP]) is missing or it contains errors.

Reaction

Class

7

Stop of axis, plane compensation remains inactive

Solution

Class

6

Correct the compensation table s. [COMP]

Parameter

%1:

Logical axis number [-]

Logical axis number P-AXIS-00016 of affected axis

Error type

-

 

70321

Activation of plane compensation not possible since master axes are not referenced.

 

Description

The master axes of the plane compensation (s. [FCT-C5]) must be homed in order to turn the compensation on. The correction values for the slave axis are calculated in dependcy of the positions of the master axes.

Possible solutions:

- Homing of the master axes (s. [FCT-M1])

- If the master axes use an absolute path measuring system, the parameter P-AXIS-00014 can be set to 1 for the master axes so that no homing of these axes is necessary.

Reaction

Class

1

Warning, plane compensation remains inactive until master axes are homed

Solution

Class

1

Homing of the master axes(s. [FCT-M1])

Parameter

%1:

Logical axis number [-]

Logical axis number P-AXIS-00016 of affected slave axis

%2:

Logical axis number [-]

Logical axis number P-COMP-00014 of the first master axis

%3:

Actual value [-]

TRUE, if axis is homed

%4:

Logical axis number [-]

Logical axis number P-COMP-00015 of the second master axis

%5:

Actual value [-]

TRUE, if axis is homed

Error type

-

 

70322 / 70323

 

 

Description

This error message informs about internal states, error solutions and the place of error in the source.Please give the complete error message data to the CNC manufacturer.

Reaction

Class

7

 

Solution

Class

8

Restart of NC-control necessary.

70324

Encoder overflow offset bigger than encoder range.

 

Description

The shift of the encoder overflow (P-AXIS-00354) is bigger than the distance moved within one encoder revolution.

Reaction

Class

5

Stop of the axis

Solution

Class

1

 

Parameter

%1:

Logical axis number [-]

Logical axis number of affected axis s. P-AXIS-00016

%2:

Incorrect value [0.1 µm or 0,0001°]

Setup value for P-AXIS-00354.

%3:

Limit value [0.1 µm or 0,0001°]

Limit value for P-AXIS-00354.

%4:

Corrected value [0.1 µm or 0,0001°]

Corrected value of P-AXIS-00354.

Error type

6, Error message by data transfer into control device.

 

70325

Axis movement from axis compensation while feedhold.

 

Description

The cross and plane compensation (s. [FCT-C5]) correct the position of the slave axis in dependency of the position(s) of the master axis (axes). The slave axis is moved by the compensation, e.g. if a master axis is moved in a different CNC channel, although feedhold (s. [HLI]) is set for the slave axis

Possible solutions:

- Remove feedhold from slave axis

- Stop the master axis (axes) if feedhold is set for slave axis

- Turn axis compensation off during feedhold

Reaction

Class

1

Warning

Solution

Class

1

Remove feedhold from slave axis

Parameter

%1:

Logical axis number [-]

Logical axis number P-AXIS-00016 of affected slave axis

%2:

Drive type [-]

Drive type of affected axis s. P-AXIS-00020

%3:

Block number [-]

Logical axis number of moved master axis P-COMP-00005, P-COMP-00014, P-COMP-00015

%4:

Logical axis number [-]

Block number of the NC program in the channel of the master axis, in which the error occurred.

Error type

11, Error message from position controller.

 

70326

Timeout while drive operation mode switch.

 

Description

The operation mode of a drive could not be switched within the specified time.

Reaction

Class

5

Stop of axis

Solution

Class

6

Use drive documentation to solve reason why mode switch was not executed.

Parameter

%1:

Logical axis number [-]

Logical axis number for axis.

%2:

Actual value [-]

Operation mode requested from CNC

%3:

Incorrect value [-]

Actual operation mode of drive

%4:

Limit value [-]

Time limit

Error type

11, Error message from position controller.

 

70328

 

 

Description

This error message informs about internal states, error solutions and the place of error in the source.Please give the complete error message data to the CNC manufacturer.

Reaction

Class

5

Output of this error message, the supernumerous actual positions are ignored.

Solution

Class

8

Restart of NC-control necessary.

70329

Sensor signal: step of actual value oversized.

 

Description

 

Reaction

Class

5

 

Solution

Class

6

 

Parameter

%1:

Actual value [0.1 µm or 0,0001°]

 

%2:

Limit value [0.1 µm or 0,0001°]

 

%3:

Logical axis number [-]

 

%4:

Drive type [-]

 

%5:

Block number [-]

 

Error type

-

 

70330

Sensor complete drop out.

 

Description

 

Reaction

Class

5

 

Solution

Class

6

 

Parameter

%1:

Actual value [0.1 µm or 0,0001°]

 

%2:

Limit value [0.1 µm or 0,0001°]

 

%3:

Logical axis number [-]

 

%4:

Drive type [-]

 

%5:

Block number [-]

 

Error type

-

 

70331

Tactile drivergence oversized.

 

Description

 

Reaction

Class

5

 

Solution

Class

6

 

Parameter

%1:

Actual value [0.1 µm or 0,0001°]

 

%2:

Limit value [0.1 µm or 0,0001°]

 

%3:

Logical axis number [-]

 

%4:

Actual value [0.1 µm or 0,0001°]

 

%5:

Block number [-]

 

Error type

-

 

70332

Function DIST_CTRL ON at program end.

 

Description

 

Reaction

Class

5

 

Solution

Class

6

 

Parameter

%1:

Logical axis number [-]

 

%2:

Block number [-]

 

Error type

-

 

70333

Function DIST_CTRL ON and release axis.

 

Description

 

Reaction

Class

5

 

Solution

Class

6

 

Parameter

%1:

Logical axis number [-]

 

%2:

Block number [-]

 

Error type

-

 

70334

Function DIST_CTRL ON by actual deselection.

 

Description

 

Reaction

Class

5

 

Solution

Class

6

 

Parameter

%1:

Logical axis number [-]

 

%2:

Block number [-]

 

Error type

-

 

70335

Function DIST_CTRL ON witout SET_POS.

 

Description

 

Reaction

Class

5

 

Solution

Class

6

 

Parameter

%1:

Logical axis number [-]

 

%2:

Block number [-]

 

Error type

-

 

70336

Function DIST_CTRL is not activated.

 

Description

 

Reaction

Class

5

 

Solution

Class

6

 

Parameter

%1:

Logical axis number [-]

 

%2:

Block number [-]

 

Error type

-

 

70337

Time delay for disabling drive after PLC watchdog error is different for master-/slave axis.

 

Description

The parameter P-AXIS-00367 specifies a time delay, after that the CNC removes the drive releases at the latest if a PLC watchdog error (s. [HLI]) occurs. The value of P-AXIS-00367 must be equal for all axes belonging to a same gantry system.

Reaction

Class

1

Warning and correction of time delay for the slave axis

Solution

Class

1

Correct parameter P-AXIS-00367

Parameter

%1:

Logical axis number [-]

Logical axis number P-AXIS-00016 of affected gantry slave axis

%2:

Logical axis number [-]

Logical axis number P-AXIS-00016 of affected gantry master axis

%3:

Incorrect value [1 µsec]

Time delay P-AXIS-00367 of slave axis

%4:

Incorrect value [1 µsec]

Time delay P-AXIS-00367 of master axis

%5:

Corrected value [1 µsec]

Corrected time delay P-AXIS-00367 for slave axis

Error type

-

 

70338

No actual position configured for input axis os axwise trandformation.

 

Description

For an axis specific input transformation an axis was configured as auxiliary input which has no position encoder configured.

Reaction

Class

5

Output of this error message, the output value of the transformation is set to zero and tracking is set for this axis.

Solution

Class

7

Change configuration, auxiliary input axes are only possible for axes with an position encoder.

Parameter

%1:

Logical axis number [-]

Logical axis number of axis with no position encoder configured.

%2:

Drive type [-]

Drive type of axis without configured position encoder.

Error type

-

 

70339

Invalid axis number configured for input axis of axwise transformation.

 

Description

For an axis specific input transformation an auxiliary input variable with an unknown axis number was configured.

Reaction

Class

5

Output of this error message, the output value of the transformation is set to zero and tracking is set for this axis.

Solution

Class

7

Change configuration

Parameter

%1:

Logical axis number [-]

Unknown logical axis number.

Error type

-

 

70340

Bei der Initialisierung der achsspez. Transformation ist eine Fehler aufgetreten.

 

Description

An error occured during the initialisation of the axis specific input filter.

Reaction

Class

5

Output of this error message, the output value of the transformation is set to zero and tracking is set for this axis.

Solution

Class

7

Change configuration.

Parameter

%1:

Logical axis number [-]

Logical axis number of axis with input transformation.

%2:

Logical axis number [-]

Transformation id of input transformation.

Error type

-

 

70341

Homing is not supported for this kind of axis specific transformation.

 

Description

An axis specific input transformation, which does not support homing, is active for this axis and homing was started.

Reaction

Class

5

Output of this error message, abortion of program.

Solution

Class

7

 

Parameter

%1:

Logical axis number [-]

Logical axis number.

Error type

-

 

70342

Axis transformation error.

 

Description

An axis specific transformation was actived.

The error only can occur because of missing or incomplete parameter setting of an axis specific transformation.

Further information to functionality see

Reaction

Class

5

Output of this error, programm termination.

Solution

Class

6

Check the parameter setting for the selected axis specific transformation.

Parameter

%1:

Logical axis number [-]

Logical axis numberof affected axis.

%2:

Actual value [-]

Info variable

%3:

Actual value [-]

Current selected transformation ID.

Error type

-

 

70343

For this operation mode the position lag has to be configured in the command value telegram.

 

Description

An axis shall be operated position controlled in DSC-mode. For this operation mode it is necessary that the position lag is configured in the cyclic command values telegram.

Reaction

Class

5

Ourput of this error message, reset is locked.

Solution

Class

7

Add position lag to cyclic command value telegram or change operation mode of the axis.

Parameter

%1:

Logical axis number [-]

Logical axis number (see P-AXIS-00016)

%2:

Drive type [-]

Drive type (siehe auch P-AXIS-00020).

%3:

Actual value [-]

Configured operation mode (siehe auch P-AXIS-00320).

Error type

-

 

70344

For this operation mode the position controller gain has to be configured in the command value telegram.

 

Description

An axis shall be operated position controlled in DSC-mode. For this operation mode it is necessary that the position controller gain is configured in the cyclic command values telegram.

Reaction

Class

5

Ourput of this error message, reset is locked.

Solution

Class

7

Add position contoller gain to cyclic command value telegram or change operation mode of the axis.

Parameter

%1:

Logical axis number [-]

Logical axis number (see P-AXIS-00016)

%2:

Drive type [-]

Drive type (siehe auch P-AXIS-00020).

%3:

Actual value [-]

Configured operation mode (siehe auch P-AXIS-00320).

Error type

-

 

70345

Only spindles can be operated in open position loop mode.

 

Description

An axis shall be operated without closed position loop. This is only for spindles possible. See P-AXIS-00320.

Reaction

Class

5

Ourput of this error message, reset is locked.

Solution

Class

7

Change operation mode of axis (see P-AXIS-00320) and restart control.

Parameter

%1:

Logical axis number [-]

Logical axis number (see P-AXIS-00016)

%2:

Drive type [-]

Drive type (siehe auch P-AXIS-00020).

%3:

Actual value [-]

Configured operation mode (siehe auch P-AXIS-00320).

%4:

Actual value [-]

Internal operation mode.

%5:

Actual value [-]

Configured axis type (See P-AXIS-00018)

Error type

-

 

70346

For this operation mode the command position has to be configured in the command value telegram.

 

Description

An axis shall be operated by output of command positions and position control in the drive.. For this operation mode it is necessary that the command position is configured in the cyclic command values telegram.

Reaction

Class

5

Ourput of this error message, reset is locked.

Solution

Class

7

Add command position to cyclic command value telegram or change operation mode of the axis.

Parameter

%1:

Logical axis number [-]

Logical axis number (see P-AXIS-00016)

%2:

Drive type [-]

Drive type (siehe auch P-AXIS-00020).

%3:

Actual value [-]

Configured operation mode (siehe auch P-AXIS-00320).

Error type

-

 

70347

 

 

Description

This error message informs about internal states, error solutions and the place of error in the source.Please give the complete error message data to the CNC manufacturer.

Reaction

Class

5

 

Solution

Class

8

Restart of NC-control necessary.

70348

Delay time for acceleration feedforward is bigger than cycle time.

 

Description

The delay time for acceleration feedforward was set up to a value bigger than or equal to the interpolator cycle time.

Reaction

Class

1

Output of this error message, the delay for acceleration feedforward is disabled (P-AXIS-00390 set to zero).

Solution

Class

1

Set P-AXIS-00390 to a value less than the interpolator cycle time.

Parameter

%1:

Logical axis number [-]

Log. Axis number. (see P-AXIS-00016).

%2:

Actual value [1 µsec]

Erroneous value of P-AXIS-00390.

%3:

Corrected value [1 µsec]

Corrected value of P-AXIS-00390.

Error type

2, Error message by data transfer from parameter list into control device.

 

70349

Delay time for velocity feedforward is bigger than cycle time.

 

Description

The delay time for velocity feedforward (see also P-AXIS-00389) was set up to a value bigger than or equal to the interpolator cycle time.

Reaction

Class

1

Output of this error message, the delay for velocity feedforward is disabled (P-AXIS-00389 set to zero).

Solution

Class

1

Set P-AXIS-00389 to a value less than the interpolator cycle time.

Parameter

%1:

Logical axis number [-]

Log. Axis number. (see P-AXIS-00016).

%2:

Actual value [1 µsec]

Erroneous value of P-AXIS-00389.

%3:

Corrected value [1 µsec]

Corrected value of P-AXIS-00389.

Error type

2, Error message by data transfer from parameter list into control device.

 

70350

Velocity feedforward with additiv command value activ, but none configure additiv velocity command value.

 

Description

In parameter P-AXIS-00223 velocity feedforward via an additive velocity comand value was activated (bit 0x100 is set) but in the cyclic process data no additive velocity comand value is configured.

Reaction

Class

5

Output of this error message, velocity feedforward is disabled (bits 0x100 and 0x001 in P-AXIS-00223 are cleared).

Solution

Class

6

Clear either Bit 0x100 in P-AXIS-00223 or configure an additive velocity comand value in the cyclic process data.

Parameter

%1:

Actual value [-]

Log. Axis number. (see P-AXIS-00016).

%2:

Actual value [-]

Erroneous value of P-AXIS-00223.

%3:

Corrected value [-]

Corrected value of P-AXIS-00223.

Error type

-

 

70351

Acceleration feedforward with additiv command value activ, but none configure additiv torque command value.

 

Description

In parameter P-AXIS-00223 acceleration feedforward via an additive torque comand value was activated (bit 0x200 is set) but in the cyclic process data no additive torque comand value is configured.

Reaction

Class

5

Output of this error message, velocity feedforward is disabled (bits 0x200 and 0x002 in P-AXIS-00223 are cleared).

Solution

Class

6

Clear either Bit 0x200 in P-AXIS-00223 or configure an additive torque comand value in the cyclic process data.

Parameter

%1:

Actual value [-]

Log. Axis number. (see P-AXIS-00016).

%2:

Actual value [-]

Erroneous value of P-AXIS-00223.

%3:

Corrected value [-]

Corrected value of P-AXIS-00223.

Error type

-

 

70355

Timeconst for balancing filter (P-AXIS_00361) is to small.

 

Description

The cutoff frequency of the PT2 element defined by P-AXIS-00361 is bigger than half of the system sampling rate (1/interpolator cycle time).

Reaction

Class

7

If this error message occurs at startup of the control P-AXIS-00361 is set to zero and so feedforward balancing disabled.

If this error message occurs when an axis parameter list is updated the new, erroneous value is discarded.

Solution

Class

1

Enter correct value of P-AXIS-00361. P-AXIS-00361 must be bigger than the value in parameter 5 of the error message.

Parameter

%1:

Logical axis number [-]

Log. Axis number. (see P-AXIS-00016).

%2:

Incorrect value [-]

Cutoff frequency of the balancing filter in Hertz.

%3:

Limit value [-]

Maximal allowable cutoff frequency in Hertz

%4:

Incorrect value [1 µsec]

Set up value of P-AXIS-00361.

%5:

Lower limit value [1 µsec]

Minimal allowable value of P-AXIS-00361.

Error type

-

 

70356

Command position of position controller and drive inconsistent.

 

Description

 

Reaction

Class

1

 

Solution

Class

1

 

Parameter

%1:

Logical axis number [-]

 

%2:

Actual value [-]

 

%3:

Actual value [0.1 µm or 0,0001°]

 

%4:

Actual value [0.1 µm or 0,0001°]

 

%5:

Actual value [0.1 µm or 0,0001°]

 

Error type

11, Error message from position controller.

 

70357

Invalid probing channel programmed.

 

Description

For a NC command “MC_TouchProbeChannel” (see also [PROG] a channel number was passed as parameter , which is outside the valid range for that parameter.

Reaction

Class

7

Output of error message, abortion of programm.

Solution

Class

6

Use correct channel number.

Parameter

%1:

Logical axis number [-]

 

%2:

Lower limit value [-]

 

%3:

Upper limit value [-]

 

%4:

Incorrect value [-]

 

Error type

-

 

70358

X-axis is not programmed after the Sync-In command.

 

Description

 

Reaction

Class

4

 

Solution

Class

6

 

Parameter

%1:

Actual value [-]

 

%2:

Actual value [-]

 

Error type

1, Error message from NC-program.

 

70359

X-axis is not programmed after the Sync-Out command.

 

Description

 

Reaction

Class

4

 

Solution

Class

6

 

Parameter

%1:

Actual value [-]

 

%2:

Actual value [-]

 

Error type

1, Error message from NC-program.

 

70360

 

 

Description

This error message informs about internal states, error solutions and the place of error in the source.Please give the complete error message data to the CNC manufacturer.

Reaction

Class

3

 

Solution

Class

8

Restart of NC-control necessary.

70361

Length of output process data excceeds length of configured process data.

 

Description

When trying to write data in the process data of the axis the admissible length of the process data was exceeded.

Reaction

Class

7

 

Solution

Class

6

 

Parameter

%1:

Logical axis number [-]

Logical axis number P-AXIS-00016 of the axis.

%2:

Actual value [-]

Index of the erroneous data segment

%3:

Actual value [-]

Offset of the erroneous data segment

%4:

Actual value [-]

Length of the erroneous data segment

%5:

Actual value [-]

Configureed process data length

Error type

-

 

70362

Attempt to write process data while axis is moving.

 

Description

It was tried to write in the process data of the axis while the axis was interpolated.

Reaction

Class

7

Closed-loop controlled stop of axis

Solution

Class

6

Write process data when axis is in stoppage.

Parameter

%1:

Logical axis number [-]

Logical axis number P-AXIS-00016 of the axis.

%2:

Actual value [-]

 

Error type

1, Error message from NC-program.

 

70363

Tool change with changing gear ratio only permitted in axis standstill.

 

Description

The position controller executes a gear switch if a tool with a gear is changed (s. [TOOL]). Therefore, changing a tool with a gear ratio is only permitted in standstill due to security reasons.

Reaction

Class

7

Closed-loop controlled stop of axis

Solution

Class

6

Stop the spindle before changing the tool.

Parameter

%1:

Logical axis number [-]

Logical axis number P-AXIS-00016 of affected axis

%2:

Actual value [-]

Interpolation end (TRUE/FALSE)

%3:

Actual value [-]

Axis in position window (TRUE/FALSE)

Error type

-

 

70364 / 70365

 

 

Description

This error message informs about internal states, error solutions and the place of error in the source.Please give the complete error message data to the CNC manufacturer.

Reaction

Class

7

 

Solution

Class

8

Restart of NC-control necessary.

70366

Permissible range execeeded during tool gear change.

 

Description

A tool with a gear was changed for a spindle axis (s. [TOOL]). However, a parameter value exceeded valid range during gear change in the position controller.

Reaction

Class

7

Closed-loop controlled stop of axis, gear switch is aborted

Solution

Class

6

Correct the parameter value

Parameter

%1:

Upper limit value [Increment]

Permissible limit

%2:

Logical axis number [-]

Logical axis number P-AXIS-00016 of affected axis.

%3:

Incorrect value [Increment]

Invalid parameter value

%4:

Corrected value [Increment]

Corrected parameter value

%5:

Actual value [Increment/0.1µm]

Path resolution of axis s. P-AXIS-00234, P-AXIS-00233

Error type

2, Error message by data transfer from parameter list into control device.

 

70367

Tool change with changing gear ratio not permitted for gantry axes.

 

Description

Changing a tool with a gear ratio (automatic gear change in position controller, s. [TOOL]) is not permitted for gantry axes.

Reaction

Class

7

Closed-loop controlled stop of axis

Solution

Class

6

Correct the NC-program

Parameter

%1:

Logical axis number [-]

Logical axis number P-AXIS-00016 of affected axis.

%2:

Actual value [-]

Operation mode P-AXIS-00015 of affected axis.

Error type

-

 

70368

Change of movement direction only permitted in axis standstill.

 

Description

The axis parameters P-AXIS-00230 and P-AXIS-00231 allow a sign reversal of the actual position or the set position/value in the position controller. The value of both parameters can be changed with a parameter update, if the operation mode P-AXIS-00015 ALLOW_RESOULTION_CHANGE = 0x00400000 is set for the axis. This is however permitted only in axis standstill due to security reasons.

Reaction

Class

7

Closed-Loop controlled stop of axis, parameter changes are dismissed

Solution

Class

7

Stop axis before updating the parameters P-AXIS-00230 and P-AXIS-00231.

Parameter

%1:

Logical axis number [-]

Logical axis number P-AXIS-00016 of affected axis.

%2:

Actual value [-]

Actual value of P-AXIS-00230 sign reversal of actual value

%3:

Actual value [-]

Actual value of P-AXIS-00231 sign reversal of set value/position

%4:

Incorrect value [-]

New value for P-AXIS-00230 sign reversal of actual value

%5:

Incorrect value [-]

New value for P-AXIS-00231 sign reversal of set value/position

Error type

11, Error message from position controller.

 

70369

Tool gear change not possible. Gear ratio not active!

 

Description

This error message is a consecutive error. An update of the axis parameters was executed for a spindle axis with active tool gear (s. [TOOL]). Due to the changed parameters the tool gear could not be reactivated. The tool gear ratio is therefore no longer active.

Reaction

Class

7

Closed-loop controlled stop of axis

Solution

Class

7

Correct parameter error, reselect tool

Parameter

%1:

Logical axis number [-]

Logical axis number P-AXIS-00016 of affected axis.

%2:

Actual value [-]

Active tool gear ratio s. P-TOOL-00016, P-TOOL-00017

%3:

Actual value [-]

Reversal of rotation direction s. P-TOOL-00018

%4:

Actual value [-]

Path resolution of axis s. P-AXIS-00234, P-AXIS-00233

Error type

-

 

70370

Setting reference position not possible because bus does not deliver valid data.

 

Description

Command for setting refference position was set via HLI (see also [HLI - Setting reference position] but the field bus does not deliver valid actual positions. Setting the reference position is not possible in this situation.

Reaction

Class

7

Stop of axis

Solution

Class

6

Set refernce position when valid actual positions are delivered from the field bus.

Parameter

%1:

Logical axis number [-]

Logical axis number (see P-AXIS-00016)

%2:

Actual value [-]

Flag indicates if field bus delivers valid actual positions.

Error type

-

 

70371

Restoration of axis position not possible.

 

Description

The axis position could not be restored from the retain data at startup of the control.

Possible reasons are:

- Version change in the CNC that affected the retain data.

- The retain data could not be loaded.

Reaction

Class

7

Axis is not referenced.

Solution

Class

6

Set axis position new.

Parameter

%1:

Logical axis number [-]

Logical axis number P-AXIS-00016 of the axis.

%2:

Actual value [-]

Flag that indicated if retain data is valid.

Error type

-

 

70372

Shifting of reference offset for axes with power not possible.

 

Description

P-AXIS-00341 was changed while the axis was enabled (see also [HLI]).

Reaction

Class

2

Output of error message, changed value of P-AXIS-00341 is not taken over.

Solution

Class

6

Disable axis and change P-AXIS-00341 again.

Parameter

%1:

Logical axis number [-]

Logical axis number P-AXIS-00016 of the axis.

%2:

Actual value [0.1 µm or 0,0001°]

Actual value of P-AXIS-00341.

%3:

Incorrect value [0.1 µm or 0,0001°]

Changed value of P-AXIS-00341.

%4:

Corrected value [0.1 µm or 0,0001°]

Corrected value of P-AXIS-00341.

Error type

3, Error message from communication.

 

70373

Configuration mode activated while drive is powered up.

 

Description

Configuration mode was activated, altough the axis is enabled.

Reaction

Class

7

Output of error message, configurtion mode is enabled.

Solution

Class

6

Disable axis when configuration mode is enabled.

Parameter

%1:

Logical axis number [-]

Log. Axis number. (see P-AXIS-00016).

%2:

Actual value [-]

 

%3:

Incorrect value [-]

 

Error type

-

 

70374

Achse im Konfigurationsmodus soll interpoliert werden.

 

Description

Axis shall be interpolated although it is in configuration mode.

Reaction

Class

7

Output of error message, stop of axis

Solution

Class

6

Exit configuration mode before interpolation the axis.

Parameter

%1:

Logical axis number [-]

Log. Axis number. (see P-AXIS-00016).

%2:

Actual value [-]

 

Error type

-

 

70375

Inconsistent data for spindle revolution monitoring

 

Description

Data for spindle tool revolutuion monitoring is inkonsistent.

For spindle tool revolution monitoring velocitiy limit and activation are stored inverted and noninverted.

In order to compare these two values the second (inverted) value is inverted again and then compared with the first value. If these two values differ this errormessage is aoutput.

Reaction

Class

5

Output of error message, stop of axis

Solution

Class

6

Possible reasons for this error message are:

- Konfiguration error, data was entered incorect in the configuration data.

- Error in data transmission.

In case of an coonfiguration error the data has to be corrected and the control restarted.

In case of an transmission error the control has to be reset.

Parameter

%1:

Logical axis number [-]

Log. Axis number. (see P-AXIS-00016).

%2:

Actual value [1µm/sec or 0,001°/sec]

First value.

%3:

Actual value [1µm/sec or 0,001°/sec]

Second (inverted) value, inverted again, must result to same value as Kennung_2.

Error type

11, Error message from position controller.

 

70376

Spindle revolution monitoring: Maximum permissible velocity exceeded.

 

Description

The actual spindle velocity exceeds the parameterized maximum velocity for at least 10%.

Reaction

Class

5

Output of error message, stop of axis

Solution

Class

6

Spindle revolutions are automatically limited to the maximum velocity set up in the toold data, so this error message should never occur.

If this message occurs the following reasons are possible:

- Erroneous configuration of velocity scaling either in the control or in the drive.

- Malfucntion in the drive.

- Insufficient parameter setting of velocity or position control loop causing overshoot in the actual velocity for more than 10%.

Parameter

%1:

Logical axis number [-]

Log. Axis number. (see P-AXIS-00016).

%2:

Actual value [1µm/sec or 0,001°/sec]

Actual axis velocity.

%3:

Upper limit value [1µm/sec or 0,001°/sec]

Maximum permissible axis velocity.

%4:

Actual value [Increment]

Actual axis velocity in increments per cycle.

Error type

11, Error message from position controller.

 

70377

Bei aktiver Drehzahlueberwachung wurde die Istwertsimulation aktiviert.

 

Description

 

Reaction

Class

7

 

Solution

Class

6

 

Parameter

%1:

Logical axis number [-]

 

%2:

Incorrect value [-]

 

Error type

11, Error message from position controller.

 

70378

Invalid start position in axis specific active position transformation

 

Description

While using the axis specific transformations P-AXIS-00380,an invalid position jump was detected. Change of solution variants with crank kinematic or wrong ACS axis position leads to a position jump.The permissible position jump can be modified with transformation parameters, the default value is 5 degrees. If the current active position difference exceeds the default or adjusted parameter this error message is generated.

Reaction

Class

5

Movement Stop of axis

Solution

Class

6

Correct parameters

Parameter

%1:

Logical axis number [-]

Logical axis number P-AXIS-00016 of affected axis

%2:

Actual value [-]

Internal error code

%3:

Actual value [-]

Active transformations ID P-AXIS-00381

%4:

Actual value [0.1 µm or 0,0001°]

MCS input coordinate of transformation

%5:

Actual value [0.1 µm or 0,0001°]

ACS output coordinate of transformation

Error type

-

 

70379

Maximum distance for zero pulse search is less than the encoder range.

 

Description

The maximum distance for zero pulse search resp. search of encoder overflow set up in parameterP-AXIS-00404 is less than the distance that the axis moves in one encoder revolution.

The distance moved in one encoder revolution can be defined by:

1. Use of the parameters P-AXIS-00092, P-AXIS-00362 and @P-AXIS-00363 for setting up the path resolution. P-AXIS-00092 holds the number of encoder increments per motor revolution.

2. At homing on encoder overflow (P-AXIS-00294 set to 1) the number of increments per encoder revolution is defined by the minimum value of P-AXIS-00355 and the modulo range (P-AXIS-00126 and @P-AXIS-00127) of the axis.

Reaction

Class

5

Correction of P-AXIS-00404 to the distance the axis moves while one encoder revolution, output of a warning.

Solution

Class

1

Set up value of P-AXIS-00404 so that the axis can move while zero pulse search at least the distance of one encoder revolution.

Parameter

%1:

Logical axis number [-]

Axis number (P-AXIS-00016).

%2:

Actual value [0.1 µm or 0,0001°]

Distance moved within one encoder revolution.

%3:

Incorrect value [0.1 µm or 0,0001°]

Set up value of P-AXIS-00404.

%4:

Corrected value [0.1 µm or 0,0001°]

Corrected value of P-AXIS-00404.

Error type

6, Error message by data transfer into control device.

 

70380

Maxium admissible distance for zero pulse search resp. encoder overflow search exceeded.

 

Description

During homing the maximum permissible distance for zero pulse search resp. search of encoder overflow was exceeded.

Reaction

Class

7

Stop of axis, output of error message.

Solution

Class

6

Possible reasons for this error message are:

  • Wrong setup value for P-AXIS-00404.
  • Encoder defective or wrong wired.
  • Erroneous set up of drive amplifier with respect to encoder evaluation.
  • Erroneous configuration of process data between drive and CNC.

Parameter

%1:

Logical axis number [-]

Axis number (P-AXIS-00016).

%2:

Limit value [0.1 µm or 0,0001°]

Maximum admissible distance for zero pulse search (Value of P-AXIS-00404).

%3:

Actual value [0.1 µm or 0,0001°]

Movoement distance since start of zero pulse search.

%4:

Actual value [Increment]

Actual axis position in increments.

%5:

Actual value [Increment]

Axis position at start of zero pulse seach in increments.

Error type

1, Error message from NC-program.

 

70381

Request af actual position while active back interpolation.

 

Description

During back interpolation of an axis after tracking actual positions where requested with the command #CHANNEL INIT [ACTPOS ...] see also [PROG].

Reaction

Class

7

Stop of program.

Solution

Class

6

Change NC-programm resp. PCL-programm.

When actaul positons are requested with the command #CHANNEL INIT [ACTPOS …] tracking is done internaly. It is not necessary to activate tracking with the control unit MCControlBoolUnit_FollowUp (siehe auch [HLI]).

Parameter

%1:

Logical axis number [-]

Logical axis number, see P-AXIS-00016.

%2:

Block number [-]

Block number in NC-programm.

Error type

11, Error message from position controller.

 

70382

Maximum permissible axis velocity exceeded.

 

Description

The dynamic monitoring function in the position controller has detected an exceedance of the permissible axis velocity. The permissible limit can be specified in the axis parameter P-AXIS-00407.

Possible solutions:

- If the external command interface of the position controller (s. [HLI - Chapter External commanding of an axis]) is used, check the given command positions for velocity exceedances.

- Increase the permissible velocity limit P-AXIS-00407, if the resulting velocity limit does not exceed the maximum possible velocity of the drive.

Reaction

Class

7

Closed-loop controlled stop of axis

Solution

Class

6

 

Parameter

%1:

Logical axis number [-]

Logical axis number P-AXIS-00016 of affected axis.

%2:

Incorrect value [1µm/sec or 0,001°/sec]

Incorrect axis velocity

%3:

Upper limit value [1µm/sec or 0,001°/sec]

Maximum permissible axis velocity (P-AXIS-00407 * P-AXIS-00212)

%4:

Actual value [1µm/sec or 0,001°/sec]

Resulting axis velocity from external axis commanding (s. [HLI - Chapter External commanding of an axis])

%5:

Actual value [1µm/sec or 0,001°/sec]

Ratio of actual to maximum permissible axis velocity P-AXIS-00212

Error type

-

 

70383

The scaled limit value is bigger than the maximum value of the configured data type.

 

Description

The scaled (see P-AXIS-00401) value of parameter P-AXIS-00409 is bigger than the maximum value of the data type set up with parameter P-AXIS-00399.

Reaction

Class

1

Output of a warning, P-AXIS-00409 is automatically limited to the maximum value according to P-AXIS-00399.

Solution

Class

1

Adjust P-AXIS-00409.

Parameter

%1:

Logical axis number [-]

 

%2:

Actual value [-]

Value of P-AXIS-00396 for identification of drive fucntion.

%3:

Incorrect value [-]

Set up value of P-AXIS-00409.

%4:

Actual value [-]

Scaling factor (see P-AXIS-00401).

%5:

Limit value [-]

Maximal possible value for P-AXIS-00409 according to the values of P-AXIS-00399 and P-AXIS-00401, also corrected value.

Error type

-

 

70384

The scaled limit value is smaller than the minimum value of the configured data type.

 

Description

The scaled (see P-AXIS-00401) value of parameter P-AXIS-00408 is less than the minimum value of the data type set up with parameter P-AXIS-00399.

Reaction

Class

1

Output of a warning, P-AXIS-00408 is automatically limited to the minimum value according to P-AXIS-00399.

Solution

Class

1

Adjust P-AXIS-00408.

Parameter

%1:

Logical axis number [-]

 

%2:

Actual value [-]

Value of P-AXIS-00396 for identification of drive fucntion.

%3:

Incorrect value [-]

Set up value of P-AXIS-00408.

%4:

Actual value [-]

Scaling factor (see P-AXIS-00401).

%5:

Limit value [-]

Minimal possible value for P-AXIS-00408 according to the values of P-AXIS-00399 and P-AXIS-00401, also corrected value.

Error type

-

 

70385

The configured maximum value is less than the configured minimum value.

 

Description

The set up minimum value (P-AXIS-00408) is bigger than the set up maximum value (P-AXIS-00409).

Reaction

Class

1

Output of a warning, P-AXIS-00408 and P-AXIS-00409 are swapped.

Solution

Class

1

Adjust P-AXIS-00408 and P-AXIS-00409.

Parameter

%1:

Logical axis number [-]

 

%2:

Actual value [-]

Value of P-AXIS-00396 for identification of drive fucntion.

%3:

Upper limit value [-]

Set up value of P-AXIS-00408.

%4:

Lower limit value [-]

Set up value of P-AXIS-00409.

Error type

-

 

70386

Usage of DC brake is only for spindles possible.

 

Description

Parameter P-AXIS-00410 was set to a value not equal to –1 (DC brake control was enabled), although the axis is not a spindle.

Reaction

Class

1

Output off warning, P-AXIS-00410 is set to –1.

Solution

Class

1

Use of a DC brake is only possible for spindles. Deactivate DC brake by setting P-AXIS-00410 to –1.

Parameter

%1:

Logical axis number [-]

 

%2:

Actual value [-]

Configured axis type, see P-AXIS-00018.

%3:

Incorrect value [-]

Configured value of P-AXIS-00410.

%4:

Corrected value [-]

Corrected vcalue of P-AXIS-00410.

Error type

2, Error message by data transfer from parameter list into control device.

 

70387

Invalid bitnumber for control af DC-brake.

 

Description

Parameter P-AXIS-00410 was assigned an invalid value.

Reaction

Class

1

Output of warning, P-AXIS-00410 is set to –1 (DC brake control is disabled):

Solution

Class

1

 

Parameter

%1:

Logical axis number [-]

 

%2:

Incorrect value [-]

Erroneous value of P-AXIS-00410:

%3:

Corrected value [-]

Corrected value of P-AXIS-00410.

Error type

2, Error message by data transfer from parameter list into control device.

 

70388

DC-brake control is not supported for this drive type.

 

Description

DC brake control was activated (P-AXIS-00410 was assigned a value not equal to -1), altough the configured drive type does not support control of a DC brake.

Reaction

Class

1

Output of warning, P-AXIS-00410 is set to –1 (DC brake control is disabled):

Solution

Class

1

Set P-AXIS-00410 to –1.

Parameter

%1:

Logical axis number [-]

 

%2:

Actual value [-]

Configured drive type (see P-AXIS-00020).

%3:

Incorrect value [-]

Erroneous value of P-AXIS-00410.

%4:

Corrected value [-]

Corrected value of P-AXIS-00410.

Error type

2, Error message by data transfer from parameter list into control device.

 

70389

Axis reference due to bus failure removed. Position monitoring functions (e.g. software limit switch) not active!

 

Description

The maximum permissible telegram failures (s. P-AXIS-00409) on the EtherCAT-fieldbus were exceeded. Axis without an absolute measurement system (s. P-AXIS-00014) will be marked as not referenced, since position information may be lost due to the bus failure. The position monitoring functions like software limit switch (s. [FCT-A2]) or Gantry-monitoring (s. [FCT-C11]) are deactivated for this axis.

Possible solutions:

- Restart homing of the axis

- Check the fieldbus

- Increase the permissible telegram failures (s. P-AXIS-00409)

Reaction

Class

7

Closed-loop controlled stop of axis

Solution

Class

6

Restart homing of the axis e.g. with NC-command G74

Parameter

%1:

Logical axis number [-]

Logical axis number P-AXIS-00016 of affected axis

%2:

Drive type [-]

Drive type P-AXIS-00020 of affected axis

%3:

Actual value [-]

Last homing state of axis (TRUE = axis is homed)

%4:

Corrected value [-]

Homing state after bus failure (FALSE = axis is not homed)

%5:

Actual value [-]

Value of bus failure counter

Error type

11, Error message from position controller.

 

70390

Changing measuring input for drive probing not possible for this drive type.

 

Description

 

Reaction

Class

7

 

Solution

Class

6

 

Parameter

%1:

Logical axis number [-]

 

%2:

Drive type [-]

 

%3:

Actual value [-]

 

%4:

Incorrect value [-]

 

%5:

Corrected value [-]

 

Error type

11, Error message from position controller.

 

70391

Changing measuring edge for drive probing not possible for this drive type.

 

Description

 

Reaction

Class

7

 

Solution

Class

6

 

Parameter

%1:

Logical axis number [-]

 

%2:

Drive type [-]

 

%3:

Actual value [-]

 

%4:

Incorrect value [-]

 

%5:

Corrected value [-]

 

Error type

11, Error message from position controller.

 

70392

Changing measuring parameters for external measuring signals (mess_signal_achs_steuer) not possible.

 

Description

 

Reaction

Class

7

 

Solution

Class

6

 

Parameter

%1:

Logical axis number [-]

 

%2:

Incorrect value [-]

 

%3:

Actual value [-]

 

%4:

Actual value [-]

 

%5:

Actual value [-]

 

Error type

11, Error message from position controller.

 

70393

 

 

Description

This error message informs about internal states, error solutions and the place of error in the source.Please give the complete error message data to the CNC manufacturer.

Reaction

Class

7

 

Solution

Class

8

Restart of NC-control necessary.

70394

Maxium admissible distance for homing exceeded.

 

Description

During homing the distance between the start position of homing and the actual axis command position has exeeded the value set up in parameter P-AXIS-00412. This is an indication that the homing sequence is disturbed, e. g. the reference cam was not found.

Reaction

Class

7

Abortion of program, output of error message.

Solution

Class

6

Fix reason for disturbance of homing.

Parameter

%1:

Logical axis number [-]

 

%2:

Limit value [0.1 µm or 0,0001°]

Set up value for P-AXIS-00412.

%3:

Incorrect value [0.1 µm or 0,0001°]

Distance from start position of homing.

%4:

Actual value [Increment]

Actual command value.

%5:

Actual value [0.1 µm or 0,0001°]

Modulo range of the axis.

Error type

1, Error message from NC-program.

 

70395

Life sign error pbrofibus slave

 

Description

 

Reaction

Class

1

 

Solution

Class

1

 

Parameter

%1:

Logical axis number [-]

 

%2:

Actual value [-]

 

%3:

Actual value [-]

 

%4:

Upper limit value [-]

 

Error type

-

 

70396

Denominator of axis coupling factor is zero.

 

Description

A axis coupling was set up over the HLI, with the value zero in the denominator for the fraction oft the coupling factor, see also [HLI].

Reaction

Class

7

Output of error message, axis coupling is not activated.

Solution

Class

6

 

Parameter

%1:

Logical axis number [-]

Logical axis number

%2:

Actual value [-]

Index of the erroneous coupling definition on the HLI, starting with 1.

%3:

Actual value [-]

Numerator of coupling factor fraction.

%4:

Incorrect value [-]

Denominator of coupling factor fraction, erroneous value.

Error type

-

 

70397

Coupling factor for the axis is bigger than the permissilbe maximum value.

 

Description

At activation of axis coupling via the HLI a coupling factor bigger than the maximal permissible coupling factor was set.

Reaction

Class

7

Output of error message, axis coupling is not activated.

Solution

Class

6

 

Parameter

%1:

Logical axis number [-]

Logical axis number

%2:

Actual value [-]

Index of the erroneous coupling definition on the HLI, starting with 1.

%3:

Limit value [-]

Numerator of coupling factor fraction.

%4:

Incorrect value [-]

Denominator of coupling factor fraction.

%5:

Incorrect value [-]

 

Error type

-

 

70398

 

 

Description

This error message informs about internal states, error solutions and the place of error in the source.Please give the complete error message data to the CNC manufacturer.

Reaction

Class

3

 

Solution

Class

8

Restart of NC-control necessary.

70399

Invalid transition for distance control.

 

Description

 

Reaction

Class

7

 

Solution

Class

6

 

Parameter

%1:

Logical axis number [-]

 

%2:

Block number [-]

 

Error type

-

 

70400

Axis lost its reference.

 

Description

During active reference monitoring the bitwise AND-conjunction of the input data configured with P-AXIS-00426 and the checkmask set up with P-AXIS-00425 results in the value zero.

This means the axis has lost its reference.

Reaction

Class

7

Output of error message, stop of axis.

Solution

Class

6

Claer cause for reference loss and reference axis again.

Possible causes for reference loss are:

  • Reference loss caused by changing of drive parameters during drive setup.àReference axis again after drive setup.
  • Undervoltage in buffer battery for battery buffered absolute encoders. àreplace battery.
  • Encoder limit frequency of the drive encoder is exceeded.àreduce axis velocity.

Parameter

%1:

Logical axis number [-]

 

%2:

Incorrect value [-]

Value of reference signal delivered from drive (Value of process data set up in P-AXIS-00426).

%3:

Actual value [-]

Checkmask calculated from P-AXIS-00425.

Error type

-

 

70401

Ident for axis reference test not configured in cyclic input process data.

 

Description

During active reference monitoring the bitwise AND-conjunction of the input data configured with P-AXIS-00426 and the checkmask set up with P-AXIS-00425 results in the value zero.

This means the axis has lost its reference.

Reaction

Class

5

Output of error message, stop of axis.

Solution

Class

1

Claer cause for reference loss and reference axis again.

Possible causes for reference loss are:

  • Reference loss caused by changing of drive parameters during drive setup.àReference axis again after drive setup.
  • Undervoltage in buffer battery for battery buffered absolute encoders. àreplace battery.
  • Encoder limit frequency of the drive encoder is exceeded.àreduce axis velocity.

Parameter

%1:

Logical axis number [-]

 

%2:

Incorrect value [-]

Value of reference signal delivered from drive (Value of process data set up in P-AXIS-00426).

Error type

-

 

70402

Setting/resetting of bits is not supported for this communication type.

 

Description

The data type set up in P-AXIS-00399 is either ‚BITARRAY_16’ or ‚BITARRAY_32’ although the communication type set up in P-AXIS-00397 does not support bitwise writing of drive values.

Reaction

Class

7

Output of error message, evaluation of drive functions is aborted.

Solution

Class

6

Change either P-AXIS-00399 or P-AXIS-00397.

Parameter

%1:

Logical axis number [-]

 

%2:

Actual value [-]

Name of configured drive fucntion (P-AXIS-00396).

%3:

Drive type [-]

Drive type (P-AXIS-00020).

%4:

Incorrect value [-]

Configured communication type (P-AXIS-00397).

%5:

Incorrect value [-]

Configured data type (P-AXIS-00399).

Error type

-

 

70403

The configured bitmask is to big for the configured data type.

 

Description

The bit mask set up in P-AXIS-00429 is bigger than the maximaum value of the data type set up in P-AXIS-00399.

Reaction

Class

7

Output of error message, evaluation of drive functions is aborted.

Solution

Class

6

Adjust value of P-AXIS-00429.

Parameter

%1:

Actual value [-]

 

%2:

Actual value [-]

Name of configured drive fucntion (P-AXIS-00396).

%3:

Incorrect value [-]

Configured value of P-AXIS-00429

%4:

Actual value [-]

Configured data type (P-AXIS-00399).

%5:

Incorrect value [-]

Permissible maximum value of P-AXIS-00429.

Error type

-

 

70404

Configured bitmask contains bits, that are used also from the CNC.

 

Description

The bit mask set up in P-AXIS-00429 is bigger than the maximaum value of the data type set up in P-AXIS-00399.

Reaction

Class

7

Output of error message, evaluation of drive functions is aborted.

Solution

Class

6

Adjust value of P-AXIS-00429.

Parameter

%1:

Logical axis number [-]

 

%2:

Actual value [-]

Name of configured drive fucntion (P-AXIS-00396).

%3:

Actual value [-]

Configured value of P-AXIS-00429

%4:

Actual value [-]

Configured data type (P-AXIS-00399).

%5:

Incorrect value [-]

Permissible maximum value of P-AXIS-00429.

Error type

-

 

70405

The telegram element configured for the #DRIVE command is used exclusively from the CNC.

 

Description

The telegram element configured for bitwise writing (P-AXIS-00398) is used exclusively by the CNC.

Reaction

Class

1

Output of error message, evaluation of drive functions is aborted.

Solution

Class

1

Adjust value of P-AXIS-00398.

Parameter

%1:

Logical axis number [-]

 

%2:

Actual value [-]

Name of configured drive fucntion (P-AXIS-00396).

%3:

Incorrect value [-]

Configured value of P-AXIS-00398.

Error type

-

 

70406

Number of configured user idents exceeds limit.

 

Description

During the configuration of drive functions (see [FCT-A10]) the number of configured elements in the cyclic process data that shall be written, exceeded the maximum limit

Reaction

Class

7

Abortion of program.

Solution

Class

6

Adjust value of VAL in the NC-program.

Parameter

%1:

Logical axis number [-]

Logical axis number of affected axis s. P-AXIS-00016

%2:

Drive type [-]

Drive type (P-AXIS-00020).

%3:

Limit value [-]

Actual value.

%4:

Limit value [-]

Maximum admissible value.

%5:

Actual value [-]

Name of drive function where the exceedance occurred.

Error type

-

 

70407

Position offset can not be altered after CRC error.

 

Description

 

Reaction

Class

7

 

Solution

Class

7

 

Parameter

%1:

Logical axis number [-]

 

%2:

Actual value [0.1 µm or 0,0001°]

 

%3:

Incorrect value [-]

 

Error type

-

 

70408

Invalid checksum for absolute position offset.

 

Description

 

Reaction

Class

7

 

Solution

Class

7

 

Error type

-

 

70409

Invalid checksum for absolute position offset: (Error not resetable)

 

Description

 

Reaction

Class

7

 

Solution

Class

7

 

Parameter

%1:

Logical axis number [-]

 

%2:

Incorrect value [0.1 µm or 0,0001°]

 

%3:

Incorrect value [-]

 

%4:

Incorrect value [-]

 

Error type

-

 

70410

Target axis is its own source axis, calculaltion of command position is not possible.

 

Description

At the activation of an axis coupling via the HLI (see [FCT-A9]) it was detected, that parameter P-AXIS-00436 was set for the axis, and the axis is via other active axis couplings where P-AXIS-00436 is also set for the respective axis, linked to itself as a source axis.

In such couzpling loops it is not always possible to map the drive position clear without ambiguity to the interpolator position, so that such coupling loops are prohibited.

Reaction

Class

7

Output of error message, axis coupling is not activated.

Solution

Class

6

Either break coupling loop by changing the axis coupling or set for at least one axis of the coupling loop parameter P-AXIS-00436 to zero.

Parameter

%1:

Logical axis number [-]

Axis number of asxis for which the coupling loop was detected.

%2:

Logical axis number [-]

Axis number of the axis that closes the coupling loop.

%3:

Logical axis number [-]

 

Error type

-

 

70411

Filter of additional command values interface could not be generated.

 

Description

For the additive command value interface it is possible to activate a PT2-filter to smooth the command values (s. [HLI - External commanding of an axis], P-AXIS-00438). However, the generation of the filter with the actual filter time constant P-AXIS-00438 is not possible. The detailed error information can be found in the previous error message.

Reaction

Class

3

Filter is deactivated

Solution

Class

6

Change the time constant P-AXIS-00438 of the PT2-filter

Parameter

%1:

Logical axis number [-]

Logical axis number P-AXIS-00016 of affected axis

%2:

Drive type [-]

Drive type of affected axis s. P-AXIS-00020

%3:

Actual value [1 µsec]

Time constant P-AXIS-00438 of the used PT2-filter

%4:

Incorrect value [-]

 

Error type

-

 

70412 - 70419

 

 

Description

This error message informs about internal states, error solutions and the place of error in the source.Please give the complete error message data to the CNC manufacturer.

Reaction

Class

3

 

Solution

Class

8

Restart of NC-control necessary.

70420

Characteristic filter frequency greater than half of sample frequency.

 

Description

According to the sampling theorem of Shannon, the cut-off frequency can be at the maximum (½*TA = Cycle time of numerical control). The cut-off frequency of the PT2-filter is calculated from the time constant as follows: fc = 1 / (2 * PI * P-AXIS-00438).

Possible solutions:

- Increase the time constant P-AXIS-00438 of the PT2-filter.

- Reduce the cycle time of the numerical control

Reaction

Class

3

Filter is deactivated.

Solution

Class

6

Increase the time constant P-AXIS-00438 of the PT2-filter

Error type

-

 

70421

Filter design with given parameters not possible.

 

Description

Not all filter parameters lead to a stable filter e.g. due to the limited computational accuracy. Possible solutions are:

- Try different time constants P-AXIS-00428 for the PT2-filter

- Change the cycle time of the CNC

Reaction

Class

3

Filter is deactivated

Solution

Class

6

Change filter parameters

Error type

-

 

70422

 

 

Description

This error message informs about internal states, error solutions and the place of error in the source.Please give the complete error message data to the CNC manufacturer.

Reaction

Class

3

 

Solution

Class

8

Restart of NC-control necessary.

70423

Stability reserve of designed filter not sufficient.

 

Description

Not all filter parameters lead to a stable filter e.g. due to the limited computational accuracy. Possible solutions are:

- Try different time constants P-AXIS-00428 for the PT2-filter

- Change the cycle time of the CNC

Reaction

Class

3

Filter is deactivated

Solution

Class

6

Change filter parameters

Error type

-

 

70424

 

 

Description

This error message informs about internal states, error solutions and the place of error in the source.Please give the complete error message data to the CNC manufacturer.

Reaction

Class

3

 

Solution

Class

8

Restart of NC-control necessary.

70425

Timeout after deactivation of additive command value interface. Filter not within position window.

 

Description

For the additive command value interface it is possible to activate a PT2-filter to smooth the command values (s. [HLI - External commanding of an axis], P-AXIS-00438). Due to the filter, the axis stop is little delayed, if the interface is disabled. The CNC generates this warning message, if the axis is not in standstill within a certain amount of time.

Reaction

Class

1

Display of a warning message

Solution

Class

1

Reduce the filter time constant P-AXIS-00438

Parameter

%1:

Logical axis number [-]

Logical axis number P-AXIS-00016 of affected axis

%2:

Upper limit value [1 µsec]

Elapsed time after the deactivation of the additive command value interface

%3:

Upper limit value [-]

Elapsed CNC cycles after the deactivation of the additive command value interface

%4:

Actual value [0.1 µm or 0,0001°]

Position difference: filter output – filter input

%5:

Actual value [-]

Time constant P-AXIS-00438 of the used PT2-filter

Error type

11, Error message from position controller.