SumHandleWrite Class

Write any (primitive) values by Handle SumCommand.

Inheritance Hierarchy

System.Object
  SumCommand
    SumWrite
      TwinCAT.Ads.SumCommand.SumHandleWrite
Namespace:  TwinCAT.Ads.SumCommand
Assembly:  TwinCAT.Ads (in TwinCAT.Ads.dll) Version: 4.3.0.0

Syntax

C#

public class SumHandleWrite : SumWrite

VB

Public Class SumHandleWrite
    Inherits SumWrite

The SumHandleWrite type exposes the following members.

Methods

 

Name

Description

Equals

Determines whether the specified object is equal to the current object. (Inherited from Object.)

Finalize

Allows an object to try to free resources and perform other cleanup operations before it is reclaimed by garbage collection. (Inherited from Object.)

GetHashCode

Serves as the default hash function. (Inherited from Object.)

GetType

Gets the Type of the current instance. (Inherited from Object.)

MemberwiseClone

Creates a shallow copy of the current Object. (Inherited from Object.)

ToString

Returns a string that represents the current object. (Inherited from Object.)

TryWrite

Tries to write the values.

Write

Writes the values to the Symbols.

Remarks

This is an ADS Sum Command to access values by handle information. It is always used in combination with and . By design (and in contrast to the symbolic access in SumSymbolRead, SumSymbolWrite) this access method can act only with ADS ANY Type (Primitive) values (disadvantage). The Advantage is, that no symbolic information must be loaded before accessing the values, see samples:

Examples

Usage of Sum commands with handles (CreateHandles, Read, Write, ReleaseHandles)

/// <summary>
/// Defines the entry point of the application.
/// </summary>
/// <param name="args">The arguments.</param>
static void Main(string[] args)
{
    Console.WriteLine("");
    Console.WriteLine("Press [Enter] for start:");
    Console.ReadLine();

    // Parse the command-line arguments
    AmsAddress address = ArgParser.Parse(args);

    using (TcAdsClient client = new TcAdsClient())
    {
    // Connect the AdsClient to the device target.
    client.Connect(address);

    string[] instancePathList = {"GVL.bVar", "GVL.iCount", "TwinCAT_SystemInfoVarList._AppInfo.ProjectName"};
    SumCreateHandles createHandlesCommand = new SumCreateHandles(client,instancePathList);

    uint[] handles = createHandlesCommand.CreateHandles();
    Type[] valueTypes = new Type[] { typeof(bool), typeof(short), typeof(string)};

    SumHandleRead readCommand = new SumHandleRead(client,handles,valueTypes);

    object[] readValues = readCommand.Read();

    for (int i = 0; i < instancePathList.Length; i++)
    {
        Console.WriteLine("Symbol: {0} (Value: {1}, Type: {2})",instancePathList[i],readValues[i].ToString(),valueTypes[i].Name);
    }

    // Sum Command Write
    SumHandleWrite writeCommand = new SumHandleWrite(client,handles,valueTypes);
    object[] writeValues = new object[] {true, (short) 42, "MyNewProjectName"};

    writeCommand.Write(writeValues);

    SumReleaseHandles releaseCommand = new SumReleaseHandles(client,handles);
    releaseCommand.ReleaseHandles();
    }

    Console.WriteLine("");
    Console.WriteLine("Press [Enter] for leave:");
    Console.ReadLine();
}

Reference

TwinCAT.Ads.SumCommand Namespace

TwinCAT.Ads.SumCommand.SumCreateHandles

TwinCAT.Ads.SumCommand.SumReleaseHandles

TwinCAT.Ads.SumCommand.ISumCommand

TwinCAT.Ads.SumCommand.SumReleaseHandles

TwinCAT.Ads.SumCommand.SumReleaseHandles

TwinCAT.Ads.SumCommand.SumHandleRead