SumCreateHandles Class

SumCommand for getting variable handles by a set of InstancePaths

Inheritance Hierarchy

System.Object
  SumCommandWrapper.SumReadWrite.
    TwinCAT.Ads.SumCommand.SumCreateHandles
Namespace:  TwinCAT.Ads.SumCommand
Assembly:  TwinCAT.Ads (in TwinCAT.Ads.dll) Version: 4.3.0.0

Syntax

C#

public class SumCreateHandles : SumCommandWrapper<SumReadWrite>

VB

Public Class SumCreateHandles
    Inherits SumCommandWrapper(Of SumReadWrite)

The SumCreateHandles type exposes the following members.

Constructors

 

Name

Description

SumCreateHandles(IAdsConnection, IList.String.)

Initializes a new instance of the SumCreateHandles class.

SumCreateHandles(IAdsConnection, .String.)

Initializes a new instance of the SumCreateHandles class.

Methods

 

Name

Description

CreateHandles

Creates the ADS handles.

Equals

Determines whether the specified object is equal to the current object. (Inherited from Object.)

Finalize

Allows an object to try to free resources and perform other cleanup operations before it is reclaimed by garbage collection. (Inherited from Object.)

GetHashCode

Serves as the default hash function. (Inherited from Object.)

GetType

Gets the Type of the current instance. (Inherited from Object.)

MemberwiseClone

Creates a shallow copy of the current Object. (Inherited from Object.)

ToString

Returns a string that represents the current object. (Inherited from Object.)

Examples

Usage of Sum commands with handles (CreateHandles, Read, Write, ReleaseHandles)

/// <summary>
/// Defines the entry point of the application.
/// </summary>
/// <param name="args">The arguments.</param>
static void Main(string[] args)
{
    Console.WriteLine("");
    Console.WriteLine("Press [Enter] for start:");
    Console.ReadLine();

    // Parse the command-line arguments
    AmsAddress address = ArgParser.Parse(args);

    using (TcAdsClient client = new TcAdsClient())
    {
    // Connect the AdsClient to the device target.
    client.Connect(address);

    string[] instancePathList = {"GVL.bVar", "GVL.iCount", "TwinCAT_SystemInfoVarList._AppInfo.ProjectName"};
    SumCreateHandles createHandlesCommand = new SumCreateHandles(client,instancePathList);

    uint[] handles = createHandlesCommand.CreateHandles();
    Type[] valueTypes = new Type[] { typeof(bool), typeof(short), typeof(string)};

    SumHandleRead readCommand = new SumHandleRead(client,handles,valueTypes);

    object[] readValues = readCommand.Read();

    for (int i = 0; i < instancePathList.Length; i++)
    {
        Console.WriteLine("Symbol: {0} (Value: {1}, Type: {2})",instancePathList[i],readValues[i].ToString(),valueTypes[i].Name);
    }

    // Sum Command Write
    SumHandleWrite writeCommand = new SumHandleWrite(client,handles,valueTypes);
    object[] writeValues = new object[] {true, (short) 42, "MyNewProjectName"};

    writeCommand.Write(writeValues);

    SumReleaseHandles releaseCommand = new SumReleaseHandles(client,handles);
    releaseCommand.ReleaseHandles();
    }

    Console.WriteLine("");
    Console.WriteLine("Press [Enter] for leave:");
    Console.ReadLine();
}