Installation options

TwinCAT 3 is delivered with a component-based setup that you can download from the Download section on the Beckhoff homepage.

TwinCAT 3 is installed by default in the directory C:\TwinCAT\3.x (x = TwinCAT-version number). Changing the installation path is not recommended.

The following setups are available for each new version of TwinCAT 3.1:

Full installation - TwinCAT 3.1 eXtended Automation Engineering (XAE)

The full installation of TwinCAT 3.1 contains various installation options that you can select during the installation:

Installation option

Scope

Use

Full installation - TwinCAT 3 Engineering and Runtime

(Standard installation)

Installs the complete TwinCAT system on a single PC:

  • TwinCAT 3 Engineering (XAE, development system/environment)
  • local TwinCAT 3 Runtime (real-time runtime system/environment, XAR)
  • First installation
  • On development workstations that use the PC at the same time as a control computer.
  • No external test system required: you can also use the development system as a test system. Additional control hardware for tests is not absolutely necessary.

TwinCAT 3 Engineering full installation

Installs the TwinCAT 3 Engineering for the development computer

  • If the control computer is always strictly separated from the development system.
  • External test system required: you CANNOT use the development computer as a test system for the control program.

Full installation - TwinCAT 3 Runtime

Installs the TwinCAT 3 Runtime for the control computer

The TwinCAT 3 Runtime (XAR) is already pre-installed on many Beckhoff IPCs or can be ordered as an option.

  • For pure control computers without a development system

See also:

Installation of the TwinCAT 3 eXtended Automation Runtime (XAR)

This installation contains only the components that are needed for the TwinCAT 3 Runtime. The setup is thus much smaller than that for the full installation of TwinCAT 3.

Typical application for the setup:

Installation of the TwinCAT 3 Engineering Remote Manager

This installation contains only the engineering components of a TwinCAT 3 version and cannot be installed stand-alone. It always requires a newer full version of TwinCAT 3.1.

Typical application for the setup:

Installation of TwinCAT 3 ADS

This installation contains only the components necessary for the use of ADS. ADS (TwinCAT Automation Device Specification) is a medium-independent protocol for communication with/between TwinCAT components. ADS is normally installed automatically together with TwinCAT 3 XAE or TwinCAT 3 XAR.

Typical application for the setup:

See also: