ITcSysManager::LookupTreeItem

The LookupTreeItem() method returns a ITcTreeItem pointer of a tree item given by it's full path name.

 

Parameters

bstrItem

[in] path name of the tree item looking for. The full path name is required and each branch must be separated by a circumflex accent '^' or a tab. A list of shortcuts for the main tree items is listed below.

pipItem

[out, retval] points to the location of a ITcSmTreeItem interface pointer on return. The interface pointer gives access to specific methods belonging to the tree item.

Return Values

S_OK

function returns successfully.

TSM_E_ITEMNOTFOUND (0x98510001)

the path name does not qualify an existing tree item.

Shortcuts

The main tree items that exists in every configuration file can be accessed via shortcuts. These shortcuts are language neutral and require less memory:

"TIIC": shortcut for "I/O Configuration"
“TIID": shortcut for "I/O Configuration^I/O Devices" or "I/O Configuration" TAB "I/O Devices"
“TIRC": shortcut for "Real-Time Configuration"
TIRR": shortcut for "Real-Time Configuration^Route Settings"
TIRT": shortcut for " Real-Time Configuration^Additional Tasks" or " Real-Time Configuration" TAB "Additional Tasks"
TIRS": shortcut for " Real-Time Configuration^Real-Time Settings" or " Real-Time Configuration" TAB "Real-Time Settings"
TIPC": shortcut for "PLC Configuration"
TINC": shortcut for "NC Configuration"
TICC": shortcut for "CNC Configuration"
TIAC": shortcut for "CAM Configuration"

Sample (C++):

 

Sample (VB):Dim ipItem As ITcSmTreeItem
set ipItem = spTsm.LookupTreeItem("TIID^Device 1 (C1220)")
' do anything with ipItem