ReadOnlyRpcMethodCollection Class

Read only RpcMethodCollection

Inheritance Hierarchy

System.Object
  System.Collections.ObjectModel.ReadOnlyCollection.IRpcMethod.
    TwinCAT.TypeSystem.ReadOnlyRpcMethodCollection
Namespace:  TwinCAT.TypeSystem
Assembly:  TwinCAT.Ads (in TwinCAT.Ads.dll) Version: 4.3.0.0

Syntax

C#

public class ReadOnlyRpcMethodCollection : ReadOnlyCollection<IRpcMethod>

VB

Public Class ReadOnlyRpcMethodCollection
    Inherits ReadOnlyCollection(Of IRpcMethod)

The ReadOnlyRpcMethodCollection type exposes the following members.

Properties

 

Name

Description

ReadOnlyRpcMethodCollection Class 1:

Count

Gets the number of elements contained in the ReadOnlyCollection.T. instance. (Inherited from ReadOnlyCollection.IRpcMethod..)

ReadOnlyRpcMethodCollection Class 2:

Item.Int32.

Gets the element at the specified index. (Inherited from ReadOnlyCollection.IRpcMethod..)

ReadOnlyRpcMethodCollection Class 3:

Item.String.

Gets the IRpcMethod with the specified method name.

ReadOnlyRpcMethodCollection Class 4:

Items

Returns the IList.T. that the ReadOnlyCollection.T. wraps. (Inherited from ReadOnlyCollection.IRpcMethod..)

Methods

 

Name

Description

ReadOnlyRpcMethodCollection Class 5:

Contains(String)

Determines whether this collection contains the specified method name.

ReadOnlyRpcMethodCollection Class 6:

Contains(T)

Determines whether an element is in the ReadOnlyCollection.T.. (Inherited from ReadOnlyCollection.IRpcMethod..)

ReadOnlyRpcMethodCollection Class 7:

CopyTo

Copies the entire ReadOnlyCollection.T. to a compatible one-dimensional Array, starting at the specified index of the target array. (Inherited from ReadOnlyCollection.IRpcMethod..)

ReadOnlyRpcMethodCollection Class 8:

Equals

Determines whether the specified object is equal to the current object. (Inherited from Object.)

ReadOnlyRpcMethodCollection Class 9:

Finalize

Allows an object to try to free resources and perform other cleanup operations before it is reclaimed by garbage collection. (Inherited from Object.)

ReadOnlyRpcMethodCollection Class 10:

GetEnumerator

Returns an enumerator that iterates through the ReadOnlyCollection.T.. (Inherited from ReadOnlyCollection.IRpcMethod..)

ReadOnlyRpcMethodCollection Class 11:

GetHashCode

Serves as the default hash function. (Inherited from Object.)

ReadOnlyRpcMethodCollection Class 12:

GetType

Gets the Type of the current instance. (Inherited from Object.)

ReadOnlyRpcMethodCollection Class 13:

IndexOf

Searches for the specified object and returns the zero-based index of the first occurrence within the entire ReadOnlyCollection.T.. (Inherited from ReadOnlyCollection.IRpcMethod..)

ReadOnlyRpcMethodCollection Class 14:

MemberwiseClone

Creates a shallow copy of the current Object. (Inherited from Object.)

ReadOnlyRpcMethodCollection Class 15:

ToString

Returns a string that represents the current object. (Inherited from Object.)

ReadOnlyRpcMethodCollection Class 16:

TryGetMethod(Int32, IRpcMethod.)

Tries to get the specified method.

ReadOnlyRpcMethodCollection Class 17:

TryGetMethod(String, IRpcMethod.)

Tries to get the specified method.

Reference

TwinCAT.TypeSystem Namespace