RpcMethodCollection Class

Collection of RpcMethods.

Inheritance Hierarchy

System.Object
  TwinCAT.TypeSystem.RpcMethodCollection
Namespace:  TwinCAT.TypeSystem
Assembly:  TwinCAT.Ads (in TwinCAT.Ads.dll) Version: 4.3.0.0

Syntax

C#

public class RpcMethodCollection : IList<IRpcMethod>, 
    ICollection<IRpcMethod>, IEnumerable<IRpcMethod>, IEnumerable

VB

Public Class RpcMethodCollection
    Implements IList(Of IRpcMethod), ICollection(Of IRpcMethod), 
    IEnumerable(Of IRpcMethod), IEnumerable

The RpcMethodCollection type exposes the following members.

Properties

 

Name

Description

RpcMethodCollection Class 1:

Count

Gets the number of elements contained in the ICollection.T..

RpcMethodCollection Class 2:

IsReadOnly

Gets a value indicating whether the ICollection.T. is read-only.

RpcMethodCollection Class 3:

Item.Int32.

Gets or sets the element at the specified index.

RpcMethodCollection Class 4:

Item.String.

Gets the IRpcMethod with the specified method name.

Methods

 

Name

Description

RpcMethodCollection Class 5:

Add

Adds an item to the ICollection.T..

RpcMethodCollection Class 6:

AsReadOnly

Gets a read only collection of this RpcMethodCollection

RpcMethodCollection Class 7:

Clear

Removes all items from the ICollection.T..

RpcMethodCollection Class 8:

Contains(String)

Determines whether this collection contains the specified method name.

RpcMethodCollection Class 9:

Contains(IRpcMethod)

Determines whether the ICollection.T. contains a specific value.

RpcMethodCollection Class 10:

CopyTo

Copies to.

RpcMethodCollection Class 11:

Equals

Determines whether the specified object is equal to the current object. (Inherited from Object.)

RpcMethodCollection Class 12:

Finalize

Allows an object to try to free resources and perform other cleanup operations before it is reclaimed by garbage collection. (Inherited from Object.)

RpcMethodCollection Class 13:

GetEnumerator

Returns an enumerator that iterates through the collection.

RpcMethodCollection Class 14:

GetHashCode

Serves as the default hash function. (Inherited from Object.)

RpcMethodCollection Class 15:

GetType

Gets the Type of the current instance. (Inherited from Object.)

RpcMethodCollection Class 16:

IndexOf

Determines the index of a specific item in the IList.T..

RpcMethodCollection Class 17:

Insert

Inserts an item to the IList.T. at the specified index.

RpcMethodCollection Class 18:

MemberwiseClone

Creates a shallow copy of the current Object. (Inherited from Object.)

RpcMethodCollection Class 19:

Remove

Removes the first occurrence of a specific object from the ICollection.T..

RpcMethodCollection Class 20:

RemoveAt

Removes the IList.T. item at the specified index.

RpcMethodCollection Class 21:

ToString

Returns a string that represents the current object. (Inherited from Object.)

RpcMethodCollection Class 22:

TryGetMethod(Int32, IRpcMethod.)

Tries to get the specified method.

RpcMethodCollection Class 23:

TryGetMethod(String, IRpcMethod.)

Tries to get the specified method.

Reference

TwinCAT.TypeSystem Namespace