IStructType Properties

The IStructType type exposes the following members.

Properties

 

Name

Description

IStructType Properties 1:

AllMembers

Gets all members (down the derivation hierarchy)

IStructType Properties 2:

Attributes

Gets the attributes of the IDataType (Inherited from IDataType.)

IStructType Properties 3:

BaseType

Gets the structs Base Type (Null if not derived).

IStructType Properties 4:

BaseTypeName

Gets the the Name of the Base class (if derived)

IStructType Properties 5:

BitSize

Gets the size of the IDataType in bits. (Inherited from IBitSize.)

IStructType Properties 6:

ByteSize

Gets the (aligned) size of of the Type/Instance in Bytes (Inherited from IBitSize.)

IStructType Properties 7:

Category

Gets the Data Type category (Inherited from IDataType.)

IStructType Properties 8:

Comment

Gets the comment behind the variable declaration. (Inherited from IDataType.)

IStructType Properties 9:

FullName

Gets the full name of the IDataType (Namespace + Name) (Inherited from IDataType.)

IStructType Properties 10:

HasRpcMethods

Gets a value indicating whether this instance has RPC methods (Struct types only)

IStructType Properties 11:

Id

Gets the ID of the DataType (Inherited from IDataType.)

IStructType Properties 12:

IsBitType

Gets a value indicating whether this instance is not basing on a full DataType but instead of some sort of bit mapping (Inherited from IBitSize.)

IStructType Properties 13:

IsByteAligned

Indicates that the Size of the Object is Byte aligned (BitSize % 8 == 0) (Inherited from IBitSize.)

IStructType Properties 14:

IsContainer

Gets a value indicating whether this IDataType is a container type (Inherited from IDataType.)

IStructType Properties 15:

IsPointer

Gets a value indicating whether this IDataType is a pointer type (Inherited from IDataType.)

IStructType Properties 16:

IsPrimitive

Gets a value indicating whether this IDataType is primitive (Inherited from IDataType.)

IStructType Properties 17:

IsReference

Gets a value indicating whether this IDataType is a reference type (Inherited from IDataType.)

IStructType Properties 18:

Members

Gets a readonly collection of the Members of the IStructType.

IStructType Properties 19:

Name

Gets the name of the Data Type (without namespace) (Inherited from IDataType.)

IStructType Properties 20:

Namespace

Gets the namespace string within the IDataType exists. (Inherited from IDataType.)

IStructType Properties 21:

Size

Gets the size of the object in bytes or Bits dependant on IsBitType (Inherited from IBitSize.)

Reference

IStructType Interface

TwinCAT.TypeSystem Namespace