IStructType Interface
Interface representing Struct data types
          Namespace:  TwinCAT.TypeSystem
Assembly:  TwinCAT.Ads (in TwinCAT.Ads.dll)
Version: 4.3.0.0
Syntax
C#
public interface IStructType : IDataType,
IBitSize
VB
Public Interface IStructType
Inherits IDataType, IBitSize
The IStructType type exposes the following members.
Properties
| 
                   
  | 
                   Name  | 
                   Description  | 
|---|---|---|
| 
                   
                      | 
                   Gets all members (down the derivation hierarchy)  | |
| 
                   
                      | 
                   Gets the attributes of the IDataType (Inherited from IDataType.)  | |
| 
                   
                      | 
                   Gets the structs Base Type (Null if not derived).  | |
| 
                   
                      | 
                   Gets the the Name of the Base class (if derived)  | |
| 
                   
                      | 
                   Gets the size of the IDataType in bits. (Inherited from IBitSize.)  | |
| 
                   
                      | 
                   Gets the (aligned) size of of the Type/Instance in Bytes (Inherited from IBitSize.)  | |
| 
                   
                      | 
                   Gets the Data Type category (Inherited from IDataType.)  | |
| 
                   
                      | 
                   Gets the comment behind the variable declaration. (Inherited from IDataType.)  | |
| 
                   
                      | 
                   Gets the full name of the IDataType (Namespace + Name) (Inherited from IDataType.)  | |
| 
                   
                      | 
                   Gets a value indicating whether this instance has RPC methods (Struct types only)  | |
| 
                   
                      | 
                   Gets the ID of the DataType (Inherited from IDataType.)  | |
| 
                   
                      | 
                   Gets a value indicating whether this instance is not basing on a full DataType but instead of some sort of bit mapping (Inherited from IBitSize.)  | |
| 
                   
                      | 
                   Indicates that the Size of the Object is Byte aligned (BitSize % 8 == 0) (Inherited from IBitSize.)  | |
| 
                   
                      | 
                   Gets a value indicating whether this IDataType is a container type (Inherited from IDataType.)  | |
| 
                   
                      | 
                   Gets a value indicating whether this IDataType is a pointer type (Inherited from IDataType.)  | |
| 
                   
                      | 
                   Gets a value indicating whether this IDataType is primitive (Inherited from IDataType.)  | |
| 
                   
                      | 
                   Gets a value indicating whether this IDataType is a reference type (Inherited from IDataType.)  | |
| 
                   
                      | 
                   Gets a readonly collection of the Members of the IStructType.  | |
| 
                   
                      | 
                   Gets the name of the Data Type (without namespace) (Inherited from IDataType.)  | |
| 
                   
                      | 
                   Gets the namespace string within the IDataType exists. (Inherited from IDataType.)  | |
| 
                   
                      | 
                   Gets the size of the object in bytes or Bits dependant on IsBitType (Inherited from IBitSize.)  |