IRpcStructInstance Properties

The IRpcStructInstance type exposes the following members.

Properties

 

Name

Description

IRpcStructInstance Properties 1:

Attributes

Gets the Type Attributes. (Inherited from IAttributedInstance.)

IRpcStructInstance Properties 2:

BitSize

Gets the size of the IDataType in bits. (Inherited from IBitSize.)

IRpcStructInstance Properties 3:

ByteSize

Gets the (aligned) size of of the Type/Instance in Bytes (Inherited from IBitSize.)

IRpcStructInstance Properties 4:

Category

Gets the Symbol/Datatype Category (Inherited from ISymbol.)

IRpcStructInstance Properties 5:

Comment

Gets the comment of the IInstance (Inherited from IInstance.)

IRpcStructInstance Properties 6:

DataType

Gets the IDataType of the IInstance. (Inherited from IInstance.)

IRpcStructInstance Properties 7:

HasRpcMethods

Gets a value indicating whether this instance has RPC methods (Inherited from IStructInstance.)

IRpcStructInstance Properties 8:

InstanceName

Gets the name of the instance (without periods (.) (Inherited from IInstance.)

IRpcStructInstance Properties 9:

InstancePath

Gets the relative / absolute access path to the instance (with periods (.)) (Inherited from IInstance.)

IRpcStructInstance Properties 10:

IsBitType

Gets a value indicating whether this instance is not basing on a full DataType but instead of some sort of bit mapping (Inherited from IBitSize.)

IRpcStructInstance Properties 11:

IsByteAligned

Indicates that the Size of the Object is Byte aligned (BitSize % 8 == 0) (Inherited from IBitSize.)

IRpcStructInstance Properties 12:

IsContainerType

Gets a value indicating whether this Symbol is a container type. (Inherited from ISymbol.)

IRpcStructInstance Properties 13:

IsPersistent

Gets a value indicating whether this ISymbol is persistent. (Inherited from ISymbol.)

IRpcStructInstance Properties 14:

IsPointer

Indicates that the IInstance represents a Pointer type (Pointer TO) (Inherited from IInstance.)

IRpcStructInstance Properties 15:

IsPrimitiveType

Gets a value indicating whether this instance is a primitive type. (Inherited from ISymbol.)

IRpcStructInstance Properties 16:

IsReadOnly

Gets a value indicating whether this ISymbol is read only. (Inherited from ISymbol.)

IRpcStructInstance Properties 17:

IsRecursive

Gets a value indicating whether this instance is recursive. (Inherited from ISymbol.)

IRpcStructInstance Properties 18:

IsReference

Indicates that the IInstance represents a Reference type (REFERENCE TO) (Inherited from IInstance.)

IRpcStructInstance Properties 19:

IsStatic

Gets a value indicating whether this IInstance is static. (Inherited from IInstance.)

IRpcStructInstance Properties 20:

MemberInstances

Gets the member instances of the Struct Instance. (Inherited from IStructInstance.)

IRpcStructInstance Properties 21:

Parent

Gets the parent Symbol (Inherited from ISymbol.)

IRpcStructInstance Properties 22:

RpcMethods

Gets the Method descriptions for the IRpcCallableType (Inherited from IRpcCallableInstance.)

IRpcStructInstance Properties 23:

Size

Gets the size of the object in bytes or Bits dependant on IsBitType (Inherited from IBitSize.)

IRpcStructInstance Properties 24:

SubSymbols

Gets the SubSymbols of the ISymbol (Inherited from ISymbol.)

IRpcStructInstance Properties 25:

TypeName

Gets the name of the DataType that is used for this IInstance. (Inherited from IInstance.)

Reference

IRpcStructInstance Interface

TwinCAT.TypeSystem Namespace