IReferenceType Properties

The IReferenceType type exposes the following members.

Properties

 

Name

Description

IReferenceType Properties 1:

Attributes

Gets the attributes of the IDataType (Inherited from IDataType.)

IReferenceType Properties 2:

BitSize

Gets the size of the IDataType in bits. (Inherited from IBitSize.)

IReferenceType Properties 3:

ByteSize

Gets the (aligned) size of of the Type/Instance in Bytes (Inherited from IBitSize.)

IReferenceType Properties 4:

Category

Gets the Data Type category (Inherited from IDataType.)

IReferenceType Properties 5:

Comment

Gets the comment behind the variable declaration. (Inherited from IDataType.)

IReferenceType Properties 6:

FullName

Gets the full name of the IDataType (Namespace + Name) (Inherited from IDataType.)

IReferenceType Properties 7:

Id

Gets the ID of the DataType (Inherited from IDataType.)

IReferenceType Properties 8:

IsBitType

Gets a value indicating whether this instance is not basing on a full DataType but instead of some sort of bit mapping (Inherited from IBitSize.)

IReferenceType Properties 9:

IsByteAligned

Indicates that the Size of the Object is Byte aligned (BitSize % 8 == 0) (Inherited from IBitSize.)

IReferenceType Properties 10:

IsContainer

Gets a value indicating whether this IDataType is a container type (Inherited from IDataType.)

IReferenceType Properties 11:

IsPointer

Gets a value indicating whether this IDataType is a pointer type (Inherited from IDataType.)

IReferenceType Properties 12:

IsPrimitive

Gets a value indicating whether this IDataType is primitive (Inherited from IDataType.)

IReferenceType Properties 13:

IsReference

Gets a value indicating whether this IDataType is a reference type (Inherited from IDataType.)

IReferenceType Properties 14:

Name

Gets the name of the Data Type (without namespace) (Inherited from IDataType.)

IReferenceType Properties 15:

Namespace

Gets the namespace string within the IDataType exists. (Inherited from IDataType.)

IReferenceType Properties 16:

ReferencedType

Gets the the referenced type.

IReferenceType Properties 17:

ResolvedByteSize

Get the ByteSize of the (completely) resolved Symbol

IReferenceType Properties 18:

ResolvedCategory

Gets the Category of the (completely) resolved Symbol.

IReferenceType Properties 19:

ResolvedType

Gets the (completely) resolved type

IReferenceType Properties 20:

Size

Gets the size of the object in bytes or Bits dependant on IsBitType (Inherited from IBitSize.)

Reference

IReferenceType Interface

TwinCAT.TypeSystem Namespace