IReferenceType Interface

Interface representing a reference/pointer type

Namespace:  TwinCAT.TypeSystem
Assembly:  TwinCAT.Ads (in TwinCAT.Ads.dll) Version: 4.3.0.0

Syntax

C#

public interface IReferenceType : IDataType, 
    IBitSize

VB

Public Interface IReferenceType
    Inherits IDataType, IBitSize

The IReferenceType type exposes the following members.

Properties

 

Name

Description

IReferenceType Interface 1:

Attributes

Gets the attributes of the IDataType (Inherited from IDataType.)

IReferenceType Interface 2:

BitSize

Gets the size of the IDataType in bits. (Inherited from IBitSize.)

IReferenceType Interface 3:

ByteSize

Gets the (aligned) size of of the Type/Instance in Bytes (Inherited from IBitSize.)

IReferenceType Interface 4:

Category

Gets the Data Type category (Inherited from IDataType.)

IReferenceType Interface 5:

Comment

Gets the comment behind the variable declaration. (Inherited from IDataType.)

IReferenceType Interface 6:

FullName

Gets the full name of the IDataType (Namespace + Name) (Inherited from IDataType.)

IReferenceType Interface 7:

Id

Gets the ID of the DataType (Inherited from IDataType.)

IReferenceType Interface 8:

IsBitType

Gets a value indicating whether this instance is not basing on a full DataType but instead of some sort of bit mapping (Inherited from IBitSize.)

IReferenceType Interface 9:

IsByteAligned

Indicates that the Size of the Object is Byte aligned (BitSize % 8 == 0) (Inherited from IBitSize.)

IReferenceType Interface 10:

IsContainer

Gets a value indicating whether this IDataType is a container type (Inherited from IDataType.)

IReferenceType Interface 11:

IsPointer

Gets a value indicating whether this IDataType is a pointer type (Inherited from IDataType.)

IReferenceType Interface 12:

IsPrimitive

Gets a value indicating whether this IDataType is primitive (Inherited from IDataType.)

IReferenceType Interface 13:

IsReference

Gets a value indicating whether this IDataType is a reference type (Inherited from IDataType.)

IReferenceType Interface 14:

Name

Gets the name of the Data Type (without namespace) (Inherited from IDataType.)

IReferenceType Interface 15:

Namespace

Gets the namespace string within the IDataType exists. (Inherited from IDataType.)

IReferenceType Interface 16:

ReferencedType

Gets the the referenced type.

IReferenceType Interface 17:

ResolvedByteSize

Get the ByteSize of the (completely) resolved Symbol

IReferenceType Interface 18:

ResolvedCategory

Gets the Category of the (completely) resolved Symbol.

IReferenceType Interface 19:

ResolvedType

Gets the (completely) resolved type

IReferenceType Interface 20:

Size

Gets the size of the object in bytes or Bits dependant on IsBitType (Inherited from IBitSize.)

Reference

TwinCAT.TypeSystem Namespace