DynamicRpcStructInstance Methods

The DynamicRpcStructInstance type exposes the following members.

Methods

 

Name

Description

DynamicRpcStructInstance Methods 1:

Equals

Equals (Inherited from DynamicSymbol.)

DynamicRpcStructInstance Methods 2:

GetDynamicMemberNames

Gets the dynamic member names. (Overrides DynamicStructInstance.GetDynamicMemberNames..)

DynamicRpcStructInstance Methods 3:

GetHashCode

Gets the HashCode of the Address (Inherited from DynamicSymbol.)

DynamicRpcStructInstance Methods 4:

GetMetaObject

Provides a DynamicMetaObject that dispatches to the dynamic virtual methods. The object can be encapsulated inside another DynamicMetaObject to provide custom behavior for individual actions. This method supports the Dynamic Language Runtime infrastructure for language implementers and it is not intended to be used directly from your code. (Inherited from DynamicObject.)

DynamicRpcStructInstance Methods 5:

GetType

Gets the Type of the current instance. (Inherited from Object.)

DynamicRpcStructInstance Methods 6:

DynamicRpcStructInstance Methods 7:

InvokeRpcMethod

Invokes the specified method.

DynamicRpcStructInstance Methods 8:

ReadAnyValue

Reads the value of this Value into a new created instance of the managed type (Inherited from DynamicSymbol.)

DynamicRpcStructInstance Methods 9:

ReadRawValue.

Reads the Symbols raw value (Inherited from DynamicSymbol.)

DynamicRpcStructInstance Methods 10:

ReadRawValue(Int32)

Reads the Symbols raw value (Inherited from DynamicSymbol.)

DynamicRpcStructInstance Methods 11:

ReadValue.

Reads the value of this DynamicSymbol. (Inherited from DynamicSymbol.)

DynamicRpcStructInstance Methods 12:

ReadValue(Int32)

Reads the value of this DynamicSymbol. (Inherited from DynamicSymbol.)

DynamicRpcStructInstance Methods 13:

ToString

Returns a String that represents this instance. (Inherited from DynamicSymbol.)

DynamicRpcStructInstance Methods 14:

TryBinaryOperation

Provides implementation for binary operations. Classes derived from the DynamicObject class can override this method to specify dynamic behavior for operations such as addition and multiplication. (Inherited from DynamicObject.)

DynamicRpcStructInstance Methods 15:

TryConvert

Provides implementation for type conversion operations. Classes derived from the DynamicObject class can override this method to specify dynamic behavior for operations that convert an object from one type to another. (Inherited from DynamicObject.)

DynamicRpcStructInstance Methods 16:

TryCreateInstance

Provides the implementation for operations that initialize a new instance of a dynamic object. This method is not intended for use in C# or Visual Basic. (Inherited from DynamicObject.)

DynamicRpcStructInstance Methods 17:

TryDeleteIndex

Provides the implementation for operations that delete an object by index. This method is not intended for use in C# or Visual Basic. (Inherited from DynamicObject.)

DynamicRpcStructInstance Methods 18:

TryDeleteMember

Provides the implementation for operations that delete an object member. This method is not intended for use in C# or Visual Basic. (Inherited from DynamicObject.)

DynamicRpcStructInstance Methods 19:

TryGetIndex

Provides the implementation for operations that get a value by index. Classes derived from the DynamicObject class can override this method to specify dynamic behavior for indexing operations. (Inherited from DynamicObject.)

DynamicRpcStructInstance Methods 20:

TryGetMember

Provides the implementation for operations that get member values. Classes derived from the DynamicObject class can override this method to specify dynamic behavior for operations such as getting a value for a property. (Overrides DynamicStructInstance.TryGetMember(GetMemberBinder, Object.).)

DynamicRpcStructInstance Methods 21:

TryInvoke

Provides the implementation for operations that invoke an object. Classes derived from the DynamicObject class can override this method to specify dynamic behavior for operations such as invoking an object or a delegate. (Inherited from DynamicObject.)

DynamicRpcStructInstance Methods 22:

TryInvokeMember

Provides the implementation for operations that invoke a member. Classes derived from the DynamicObject class can override this method to specify dynamic behavior for operations such as calling a method. (Overrides DynamicObject.TryInvokeMember(InvokeMemberBinder, .Object., Object.).)

DynamicRpcStructInstance Methods 23:

TryInvokeRpcMethod(String, .Object., Object.)

Tries to invoke the specified method.

DynamicRpcStructInstance Methods 24:

TryInvokeRpcMethod(IRpcMethod, .Object., Object.)

Tries to invoke the specified method.

DynamicRpcStructInstance Methods 25:

TryReadValue

Reads the Value of the IValueSymbol (Inherited from DynamicSymbol.)

DynamicRpcStructInstance Methods 26:

TrySetIndex

Provides the implementation for operations that set a value by index. Classes derived from the DynamicObject class can override this method to specify dynamic behavior for operations that access objects by a specified index. (Inherited from DynamicObject.)

DynamicRpcStructInstance Methods 27:

TrySetMember

Provides the implementation for operations that set member values. Classes derived from the DynamicObject class can override this method to specify dynamic behavior for operations such as setting a value for a property. (Overrides DynamicStructInstance.TrySetMember(SetMemberBinder, Object).)

DynamicRpcStructInstance Methods 28:

TryUnaryOperation

Provides implementation for unary operations. Classes derived from the DynamicObject class can override this method to specify dynamic behavior for operations such as negation, increment, or decrement. (Inherited from DynamicObject.)

DynamicRpcStructInstance Methods 29:

DynamicRpcStructInstance Methods 30:

TryWriteValue

Writes the specified value to the DynamicSymbol. (Inherited from DynamicSymbol.)

DynamicRpcStructInstance Methods 31:

UpdateAnyValue

Reads the value of this Value into the specified managed value. (Inherited from DynamicSymbol.)

DynamicRpcStructInstance Methods 32:

WriteAnyValue

Writes the value represented by the managed value to this Value (Inherited from DynamicSymbol.)

DynamicRpcStructInstance Methods 33:

WriteRawValue(.Byte.)

Writes the Symbol raw Value (Inherited from DynamicSymbol.)

DynamicRpcStructInstance Methods 34:

WriteRawValue(.Byte., Int32)

Writes the Symbol raw Value (Inherited from DynamicSymbol.)

DynamicRpcStructInstance Methods 35:

WriteValue(Object)

Writes the specified value to the DynamicSymbol. (Inherited from DynamicSymbol.)

DynamicRpcStructInstance Methods 36:

DynamicRpcStructInstance Methods 37:

WriteValue(Object, Int32)

Writes the specified value to the DynamicSymbol. (Inherited from DynamicSymbol.)

Reference

DynamicRpcStructInstance Class

TwinCAT.TypeSystem Namespace