Symbol Properties
The Symbol type exposes the following members.
Properties
| 
 | Name | Description | 
|---|---|---|
| 
                     | Gets the access rights. | |
| 
                     | Gets the Type Attributes. (Inherited from Instance.) | |
| 
                     | Gets the size of this Instance in bits. (Inherited from Instance.) | |
| 
                     | Gets the (aligned) size of of the Type/Instance in Bytes (Inherited from Instance.) | |
| 
                     | Gets the the DataTypeCategory of the Instance. (Inherited from Instance.) | |
| 
                     | Gets the comment. (Inherited from Instance.) | |
| 
                     | Gets the connection that produces values for this IValueSymbol | |
| 
                     | Gets the context mask of this instance. (Inherited from Instance.) | |
| 
                     | Gets the IDataType of the IInstance. (Inherited from Instance.) | |
| 
                     | Gets a value indicating whether this instance has a value. (Inherited from Instance.) | |
| 
                     | Gets the AmsAddress of the Process Image | |
| 
                     | Gets the index group of the Symbol | |
| 
                     | Gets the index offset of the Symbol | |
| 
                     | Gets the name of the instance (without periods (.) (Inherited from Instance.) | |
| 
                     | Gets the relative / absolute access path to the instance (with periods (.)) (Overrides Instance.InstancePath.) | |
| 
                     | Gets a value indicating whether this instance is not basing on a full DataType but instead of some sort of bit mapping (Inherited from Instance.) | |
| 
                     | Indicates that the Size of the Object is Byte aligned (BitSize % 8 == 0) (Inherited from Instance.) | |
| 
                     | Gets a value indicating whether the Symbols datatype is a Container type. | |
| 
                     | Gets or sets a value indicating whether an ancestor is a dereferenced Pointer | |
| 
                     | Gets or sets a value indicating whether an ancestor is a dereferenced Reference | |
| 
                     | Indicates if this instance is persistent. (Inherited from Instance.) | |
| 
                     | Gets a value indicating whether this instance is reference. (Inherited from Instance.) | |
| 
                     | Gets a value indicating whether this instance is primitive. | |
| 
                     | Indicates if this instance is read only. (Inherited from Instance.) | |
| 
                     | Gets a value indicating whether this instance is recursive. | |
| 
                     | Gets a value indicating whether this instance is reference. (Inherited from Instance.) | |
| 
                     | Gets a value indicating whether this IInstance is static. (Inherited from Instance.) | |
| 
                     | Indicates if this instance is a TcComInterfacePointer. (Inherited from Instance.) | |
| 
                     | Indicates if this instance has set TypeGuid flag. (Inherited from Instance.) | |
| 
                     | Gets the namespace name. (Inherited from Instance.) | |
| 
                     | Gets or sets the notification settings. | |
| 
                     | Gets the parent Symbol | |
| 
                     | Gets the size of the IDataType in bytes or Bits dependant on IsBitType (Inherited from Instance.) | |
| 
                     | Gets the number of SubSymbols | |
| 
                     | Gets the SubSymbols of the ISymbol | |
| 
                     | Gets the name of the DataType that is used for this IInstance. (Inherited from Instance.) | 
- Symbol.AccessRights Property
- Symbol.Connection Property
- Symbol.ImageBaseAddress Property
- Symbol.IndexGroup Property
- Symbol.IndexOffset Property
- Symbol.InstancePath Property
- Symbol.IsContainerType Property
- Symbol.IsDereferencedPointer Property
- Symbol.IsDereferencedReference Property
- Symbol.IsPrimitiveType Property
- Symbol.IsRecursive Property
- Symbol.NotificationSettings Property
- Symbol.Parent Property
- Symbol.SubSymbolCount Property
- Symbol.SubSymbols Property