ReferenceType Properties

The ReferenceType type exposes the following members.

Properties

 

Name

Description

ReferenceType Properties 1:

Attributes

Gets the attributes of the IDataType (Inherited from DataType.)

ReferenceType Properties 2:

BitSize

Gets the size of the DataType in bits. (Inherited from DataType.)

ReferenceType Properties 3:

ByteSize

Gets the (aligned) size of of the Type/Instance in Bytes (Inherited from DataType.)

ReferenceType Properties 4:

Category

Gets the Data Type category (Inherited from DataType.)

ReferenceType Properties 5:

Comment

Gets the comment. (Inherited from DataType.)

ReferenceType Properties 6:

FullName

Gets the full name of the IDataType (Namespace + Name) (Inherited from DataType.)

ReferenceType Properties 7:

Id

Gets the ID of the DataType (Inherited from DataType.)

ReferenceType Properties 8:

IsBitType

Gets a value indicating whether this IDataType is a bit mapping Type (Inherited from DataType.)

ReferenceType Properties 9:

IsByteAligned

Indicates that the Size of the Object is Byte aligned (BitSize % 8 == 0) (Inherited from DataType.)

ReferenceType Properties 10:

IsContainer

Gets a value indicating whether this IDataType is a container type (Overrides DataType.IsContainer.)

ReferenceType Properties 11:

IsPointer

Gets a value indicating whether this IDataType is a pointer type (Inherited from DataType.)

ReferenceType Properties 12:

IsPrimitive

Gets a value indicating whether this IDataType is primitive (Overrides DataType.IsPrimitive.)

ReferenceType Properties 13:

IsReference

Gets a value indicating whether this IDataType is a reference type (Inherited from DataType.)

ReferenceType Properties 14:

ManagedType

Gets the corresponding .NET Type if attached. (Overrides DataType.ManagedType.)

ReferenceType Properties 15:

Name

Gets the name of the Data Type (without namespace) (Inherited from DataType.)

ReferenceType Properties 16:

Namespace

Gets the namespace string within the IDataType exists. (Inherited from DataType.)

ReferenceType Properties 17:

ReferencedType

Gets the the referenced type.

ReferenceType Properties 18:

ResolvedByteSize

Get the ByteSize of the (completely) resolved Symbol

ReferenceType Properties 19:

ResolvedCategory

Gets the Category of the (completely) resolved Symbol.

ReferenceType Properties 20:

ResolvedType

Gets the (completely) resolved type

ReferenceType Properties 21:

Size

Gets the Size of the DataType in Bytes (Inherited from DataType.)

Reference

ReferenceType Class

TwinCAT.Ads.TypeSystem Namespace