DynamicVirtualStructInstance Methods
The DynamicVirtualStructInstance type exposes the following members.
Methods
|
|
Name |
Description |
|---|---|---|
|
|
Adds an member instance. | |
|
|
Equals | |
|
|
Returns the enumeration of all dynamic member names. | |
|
|
Gets the HashCode of the Address | |
|
|
Provides a DynamicMetaObject
that dispatches to the dynamic virtual methods. The object can be
encapsulated inside another DynamicMetaObject to
provide custom behavior for individual actions. This method
supports the Dynamic Language Runtime infrastructure for language
implementers and it is not intended to be used directly from your
code. | |
|
|
Gets the Type of the current
instance. | |
|
|
Invokes the specified RPC Method asynchronously | |
|
|
Reads the value of this Value into a new
created instance of the managed type | |
|
|
Reads the raw value of the IValueSymbol (Ads
Read / Write) | |
|
|
Reads the Symbols raw value | |
|
|
Read raw value as an asynchronous operation. | |
|
|
Reads the value of this DynamicSymbol. | |
|
|
Reads the value of this DynamicSymbol. | |
|
|
Reads the Value of the IValueSymbol
asynchronously. | |
|
|
Returns a String that represents this
instance. | |
|
|
Provides implementation for binary operations. Classes derived
from the DynamicObject class
can override this method to specify dynamic behavior for operations
such as addition and multiplication. | |
|
|
Provides implementation for type conversion operations. Classes
derived from the DynamicObject class
can override this method to specify dynamic behavior for operations
that convert an object from one type to another. | |
|
|
Provides the implementation for operations that initialize a
new instance of a dynamic object. This method is not intended for
use in C# or Visual Basic. | |
|
|
Provides the implementation for operations that delete an
object by index. This method is not intended for use in C# or
Visual Basic. | |
|
|
Provides the implementation for operations that delete an
object member. This method is not intended for use in C# or Visual
Basic. | |
|
|
Provides the implementation for operations that get a value by
index. Classes derived from the DynamicObject class
can override this method to specify dynamic behavior for indexing
operations. | |
|
|
Provides the implementation for operations that get member
values. Classes derived from the DynamicObject class
can override this method to specify dynamic behavior for operations
such as getting a value for a property. | |
|
|
Provides the implementation for operations that invoke an
object. Classes derived from the DynamicObject class
can override this method to specify dynamic behavior for operations
such as invoking an object or a delegate. | |
|
|
Provides the implementation for operations that invoke a
member. Classes derived from the DynamicObject class
can override this method to specify dynamic behavior for operations
such as calling a method. | |
|
|
Invokes the specified RPC Method | |
|
|
Invokes the specified RPC Method | |
|
|
Reads the Value of the IValueSymbol | |
|
|
Provides the implementation for operations that set a value by
index. Classes derived from the DynamicObject class
can override this method to specify dynamic behavior for operations
that access objects by a specified index. | |
|
|
Provides the implementation for operations that set member
values. Classes derived from the DynamicObject class
can override this method to specify dynamic behavior for operations
such as setting a value for a property. | |
|
|
Provides implementation for unary operations. Classes derived
from the DynamicObject class
can override this method to specify dynamic behavior for operations
such as negation, increment, or decrement. | |
|
|
Writes the specified value to the DynamicSymbol. | |
|
|
Reads the value of this Value into the
specified managed value. | |
|
|
Writes the value represented by the managed value to this
Value | |
|
|
Writes the raw value of the IValueSymbol (Ads
Read / Write) | |
|
|
Writes the raw value of the IValueSymbol (Ads
Read / Write) | |
|
|
Writes the raw value of the IValueSymbol (Ads
Read / Write) | |
|
|
Writes the specified value to the DynamicSymbol. | |
|
|
Writes the specified value to the DynamicSymbol. | |
|
|
Writes the Value of the IValueSymbol |
Extension Methods
|
|
Name |
Description |
|---|---|---|
|
|
Indicates, that the Instance value includes process memory
data, that cannot be read in one memory block. | |
|
|
Indicates, that the field is static or is not part of the
parents processimage memory location | |
|
|
Gets the Unwrapped Symbol |
Reference
DynamicVirtualStructInstance Class TwinCAT.TypeSystem Namespace
Beckhoff Automation GmbH & Co. KG 2001-2026
- DynamicVirtualStructInstance.AddMember Method
- DynamicSymbol.Equals Method
- DynamicSymbol.GetHashCode Method
- DynamicSymbol.ReadAnyValue Method
- DynamicSymbol.ReadRawValue Method
- DynamicSymbol.ReadRawValue Method (Int32)
- DynamicSymbol.ReadRawValueAsync Method
- DynamicSymbol.ReadValue Method
- DynamicSymbol.ReadValue Method (Int32)
- DynamicSymbol.ReadValueAsync Method
- DynamicSymbol.ToString Method
- DynamicSymbol.TryReadValue Method
- DynamicSymbol.TryWriteValue Method
- DynamicSymbol.UpdateAnyValue Method
- DynamicSymbol.WriteAnyValue Method
- DynamicSymbol.WriteRawValue Method (.Byte.)
- DynamicSymbol.WriteRawValue Method (.Byte., Int32)
- DynamicSymbol.WriteRawValueAsync Method
- DynamicSymbol.WriteValue Method (Object)
- DynamicSymbol.WriteValue Method (Object, Int32)
- DynamicSymbol.WriteValueAsync Method
- DynamicInterfaceInstance.GetDynamicMemberNames Method
- DynamicInterfaceInstance.InvokeRpcMethodAsync Method
- DynamicInterfaceInstance.TryGetMember Method
- DynamicInterfaceInstance.TryInvokeMember Method
- DynamicInterfaceInstance.TryInvokeRpcMethod Method (String, .Object., Object.)
- DynamicInterfaceInstance.TryInvokeRpcMethod Method (String, .Object., .Object.., Object.)
- DynamicInterfaceInstance.TrySetMember Method