Member Properties

The Member type exposes the following members.

Properties

 

Name

Description

Member Properties 1:

Attributes

Gets the Type Attributes.
(Inherited from Instance)

Member Properties 2:

BitOffset

Gets the bit offset.

Member Properties 3:

BitSize

Gets the size of this Instance in bits.
(Inherited from Instance)

Member Properties 4:

ByteOffset

Gets the byte offset.

Member Properties 5:

ByteSize

Gets the (aligned) size of of the Type/Instance in Bytes
(Inherited from Instance)

Member Properties 6:

Category

Gets the the DataTypeCategory of the Instance.
(Inherited from Instance)

Member Properties 7:

Comment

Gets the comment.
(Inherited from Instance)

Member Properties 8:

ContextMask

Gets the context mask of this instance.
(Inherited from Instance)

Member Properties 9:

DataType

Gets the IDataType of the IInstance.
(Inherited from Instance)

Member Properties 10:

HasValue

Gets a value indicating whether this instance has a value.
(Inherited from Instance)

Member Properties 11:

InstanceName

Gets the name of the instance (without periods (.)
(Inherited from Instance)

Member Properties 12:

InstancePath

Gets the relative / absolute access path to the instance (with periods (.))
(Inherited from Instance)

Member Properties 13:

IsBitType

Gets a value indicating whether this instance is not basing on a full DataType but instead of some sort of bit mapping
(Inherited from Instance)

Member Properties 14:

IsByteAligned

Indicates that the Size of the Object is Byte aligned (BitSize % 8 == 0)
(Inherited from Instance)

Member Properties 15:

IsPersistent

Indicates that this instance is persistent.
(Inherited from Instance)

Member Properties 16:

IsPointer

Gets a value indicating whether this instance is reference.
(Inherited from Instance)

Member Properties 17:

IsProperty

Gets a value indicating whether IInstance is a property.
(Inherited from Instance)

Member Properties 18:

IsReadOnly

Indicates that this instance is read only.
(Inherited from Instance)

Member Properties 19:

IsReference

Gets a value indicating whether this instance is reference.
(Inherited from Instance)

Member Properties 20:

IsStatic

Gets a value indicating whether this IInstance is static.
(Inherited from Instance)

Member Properties 21:

IsTcComInterfacePointer

Indicates that this instance is a TcComInterfacePointer.
(Inherited from Instance)

Member Properties 22:

IsTypeGuid

Indicates that this instance has set TypeGuid flag.
(Inherited from Instance)

Member Properties 23:

Namespace

Gets the namespace name.
(Inherited from Instance)

Member Properties 24:

Offset

Gets the offset of the Member within the parent StructType in bits or bytes dependent on IsBitType

Member Properties 25:

ParentType

Gets the Parent of this IField.
(Inherited from Field)

Member Properties 26:

Size

Gets the size of the IDataType in bytes or Bits dependant on IsBitType
(Inherited from Instance)

Member Properties 27:

TypeName

Gets the name of the DataType that is used for this IInstance.
(Inherited from Instance)

Member Properties 28:

ValueEncoding

Gets the value encoding of this Field
(Inherited from Field)

See Also

Reference

Member Class TwinCAT.Ads.TypeSystem Namespace

Beckhoff Automation GmbH & Co. KG 2001-2026