ResultSumHandles2 Class

Result class for an asynchronous SumCreateHandles.

Inheritance Hierarchy

System.Object
  TwinCAT.Ads.ResultAds
    TwinCAT.Ads.SumCommand.ResultSumCommand
      TwinCAT.Ads.SumCommand.ResultSumHandles
        TwinCAT.Ads.SumCommand.ResultSumHandles2

Namespace: TwinCAT.Ads.SumCommand
Assembly: TwinCAT.Ads.Abstractions (in TwinCAT.Ads.Abstractions.dll) Version: 7.0.0+e56d35ccc4675faac24789a4aab60071fc61d470

Syntax

C#

public class ResultSumHandles2 : ResultSumHandles

The ResultSumHandles2 type exposes the following members.

Constructors

 

Name

Description

ResultSumHandles2 Class 1:

ResultSumHandles2

Initializes a new instance of the ResultSumHandles2 class.

Properties

 

Name

Description

ResultSumHandles2 Class 2:

ErrorCode

Gets the ADS Error code bound to this Result object.
(Inherited from ResultAds)

ResultSumHandles2 Class 3:

Failed

Gets a value indicating whether the ResultAds state is failed.
(Inherited from ResultAds)

ResultSumHandles2 Class 4:

FirstSubError

Gets the first SubError that is not NoError
(Inherited from ResultSumCommand)

ResultSumHandles2 Class 5:

Handles

The registered Symbol handles.
(Inherited from ResultSumHandles)

ResultSumHandles2 Class 6:

InstancePaths

The symbol/instance paths belonging to the handles and the subErrors.

ResultSumHandles2 Class 7:

InvokeId

Gets the ADS requests invoke identifier (or 0 if not supported)
(Inherited from ResultAds)

ResultSumHandles2 Class 8:

OverallError

Gets the Overall (combined error) from SumCommand AND SubCommands.
(Inherited from ResultSumCommand)

ResultSumHandles2 Class 9:

OverallFailed

Gets a value indicating, whether the overall Sumcommand failed (checking all subcommand results).
(Inherited from ResultSumCommand)

ResultSumHandles2 Class 10:

OverallSucceeded

Gets a value indicating, whether the overall SumCommand succeeded (including all subcommands)
(Inherited from ResultSumCommand)

ResultSumHandles2 Class 11:

SubCommandCount

Gets the count of SubCommands.
(Inherited from ResultSumCommand)

ResultSumHandles2 Class 12:

SubErrors

Gets the Error codes for the single SumCommands.
(Inherited from ResultSumCommand)

ResultSumHandles2 Class 13:

Succeeded

Gets a value indicating whether the ResultAds state is succeeded.
(Inherited from ResultAds)

ResultSumHandles2 Class 14:

TimeStamp

Gets the time stamp of the result.
(Inherited from ResultAds)

Methods

 

Name

Description

ResultSumHandles2 Class 15:

Equals

Determines whether the specified object is equal to the current object.
(Inherited from Object)

ResultSumHandles2 Class 16:

Finalize

Allows an object to try to free resources and perform other cleanup operations before it is reclaimed by garbage collection.
(Inherited from Object)

ResultSumHandles2 Class 17:

GetHashCode

Serves as the default hash function.
(Inherited from Object)

ResultSumHandles2 Class 18:

GetType

Gets the Type of the current instance.
(Inherited from Object)

ResultSumHandles2 Class 19:

MemberwiseClone

Creates a shallow copy of the current Object.
(Inherited from Object)

ResultSumHandles2 Class 20:

SetError

Sets the error state of this ResultAds
(Inherited from ResultAds)

ResultSumHandles2 Class 21:

ToString

Returns a string that represents the current object.
(Inherited from Object)

Fields

 

Name

Description

timeStamp

The timestamp
(Inherited from ResultAds)

See Also

Reference

TwinCAT.Ads.SumCommand Namespace

Beckhoff Automation GmbH & Co. KG 2001-2026