AdsServer.AddDeviceNotificationRequest Method

Sends an ADS Add Device Notification request (synchronous).


Namespace: TwinCAT.Ads.Server
Assembly: TwinCAT.Ads.Server (in TwinCAT.Ads.Server.dll) Version: 7.0.0+e56d35ccc4675faac24789a4aab60071fc61d470

Syntax

C#

protected AdsErrorCode AddDeviceNotificationRequest(
AmsAddress target,
uint invokeId,
uint indexGroup,
uint indexOffset,
int dataLength,
NotificationSettings settings
)

Parameters

target  AmsAddress

The receiver's AMS address

invokeId  UInt32

The invokeId for this call. Used to find the matching ADS Confirmation

indexGroup  UInt32

The index group of the requested ADS service

indexOffset  UInt32

The index group of the requested ADS service

dataLength  Int32

The number of bytes to be transmitted

settings  NotificationSettings

The notification settings.

Return Value

AdsErrorCode
The ADS error code for this call.

See Also

Reference

AdsServer Class TwinCAT.Ads.Server Namespace