AdsException Class
Base class for all exceptions thrown by the TwinCAT.Ads component
Inheritance Hierarchy
SystemObject
SystemException
TwinCATAdsException
TwinCAT.AdsAdsErrorException
TwinCAT.AdsAdsInvalidNotificationException
TwinCATClientNotConnectedException
TwinCATHandleBagNotInitializedException
TwinCATSessionException
TwinCATSumCommandNotAllowedException
TwinCAT.TypeSystemDataTypeException
TwinCAT.TypeSystemMarshalException
TwinCAT.TypeSystemSymbolException
Namespace: TwinCAT
Assembly: TwinCAT.Ads.Abstractions (in TwinCAT.Ads.Abstractions.dll) Version: 7.0.0+e56d35ccc4675faac24789a4aab60071fc61d470
Syntax
C#
[SerializableAttribute]
public class AdsException : ExceptionThe AdsException type exposes the following members.
Constructors
| Name | Description |
|---|---|---|
| Initializes a new Instance of the AdsException class. | |
| AdsException(String) | Initializes a new Instance of the AdsException class. |
| AdsException(String, Exception) | Initializes a new Instance of the AdsException class. |
Properties
| Name | Description |
|---|---|---|
| Gets a collection of key/value pairs that provide additional user-defined information about the exception. | |
| Gets or sets a link to the help file associated with this exception. | |
| Gets or sets HRESULT, a coded numerical value that is assigned to a specific exception. | |
| Gets the Exception instance that caused the current exception. | |
| Gets a message that describes the current exception. | |
| Gets or sets the name of the application or the object that causes the error. | |
| Gets a string representation of the immediate frames on the call stack. | |
| Gets the method that throws the current exception. |
Methods
| Name | Description |
|---|---|---|
| Determines whether the specified object is equal to the current object. | |
| Allows an object to try to free resources and perform other cleanup operations before it is reclaimed by garbage collection. | |
| When overridden in a derived class, returns the Exception that is the root cause of one or more subsequent exceptions. | |
| Serves as the default hash function. | |
| Gets the runtime type of the current instance. | |
| Creates a shallow copy of the current Object. | |
| Creates and returns a string representation of the current exception. |
Events
| Name | Description |
|---|---|---|
| Occurs when an exception is serialized to create an exception state object that contains serialized data about the exception. |
- AdsException Class
- AdsException(String) Constructor
- AdsException(String, Exception) Constructor
- AdsException(String) Constructor
- AdsException(String, Exception) Constructor
- AdsErrorException Class
- AdsInvalidNotificationException Class
- ClientNotConnectedException Class
- SessionException Class
- DataTypeException Class
- MarshalException Class
- SymbolException Class
- HandleBagNotInitializedException Class
- SumCommandNotAllowedException Class