SumReleaseHandlesBase Class

Release Handles SumCommand (internal)

Inheritance Hierarchy

System.Object
  SumCommandWrapper<SumWrite>
    TwinCAT.Ads.SumCommand.SumReleaseHandlesBase

Namespace: TwinCAT.Ads.SumCommand
Assembly: TwinCAT.Ads (in TwinCAT.Ads.dll) Version: 7.0.0+e56d35ccc4675faac24789a4aab60071fc61d470

Syntax

C#

public class SumReleaseHandlesBase : SumCommandWrapper<SumWrite>

The SumReleaseHandlesBase type exposes the following members.

Constructors

 

Name

Description

SumReleaseHandlesBase(IAdsConnection, UInt32[])

Initializes a new instance of the SumReleaseHandlesBase class.

SumReleaseHandlesBase(IAdsConnection, UInt32[], SumFallbackMode)

Initializes a new instance of the SumReleaseHandlesBase class.

SumReleaseHandlesBase(IAdsConnection, UInt32[], SumCommandErrorStrategy, SumFallbackMode)

Initializes a new instance of the SumReleaseHandlesBase class.

Methods

 

Name

Description

Equals

Determines whether the specified object is equal to the current object.
(Inherited from Object)

Finalize

Allows an object to try to free resources and perform other cleanup operations before it is reclaimed by garbage collection.
(Inherited from Object)

GetHashCode

Serves as the default hash function.
(Inherited from Object)

GetType

Gets the Type of the current instance.
(Inherited from Object)

MemberwiseClone

Creates a shallow copy of the current Object.
(Inherited from Object)

ReleaseHandles

Releases the handles.

ReleaseHandlesAsync

Releases the handles asynchronously.

ToString

Returns a string that represents the current object.
(Inherited from Object)

Remarks

Releases the specified ADS handles. Usually used in conjunction with the SumCreateHandles and the SumHandleReadAnyType / SumHandleWriteAnyType commands. This is not removing the handles from the IHandleCache of the AdsClient.

Example

Usage of Sum commands with handles (CreateHandles, Read, Write, ReleaseHandles)

/// <summary>
/// Defines the entry point of the application.
/// </summary>
/// <param name="args">The arguments.</param>
static async void Main(string[] args)
{
    Console.WriteLine("");
    Console.WriteLine("Press [Enter] for start:");
    Console.ReadLine();

    // Parse the command-line arguments
    AmsAddress address = ArgParser.Parse(args);

    CancellationTokenSource cancelSource = new CancellationTokenSource();
    CancellationToken cancel = cancelSource.Token;

    using (AdsClient client = new AdsClient())
    {
    // Connect the AdsClient to the device target.
    client.Connect(address);

    string[] instancePathList = {
        "GVL.bVar",
        "GVL.iCount",
        "TwinCAT_SystemInfoVarList._AppInfo.ProjectName"
    };
    SumCreateHandles createHandlesCommand = new SumCreateHandles(client,instancePathList);

    var resultCreateHandles = await createHandlesCommand.CreateHandlesAsync(cancel);

    if (resultCreateHandles.Succeeded)
    {
        uint[] handles = resultCreateHandles.Handles;
        Type[] valueTypes = new Type[]
        {
        typeof(bool),
        typeof(short),
        typeof(string)
        };
        SumHandleReadAnyType readCommand = new SumHandleReadAnyType(client, handles, valueTypes, SumFallbackMode.All);
        var resultRead = await readCommand.ReadAsync(cancel);

        if (resultRead.Succeeded)
        {
        object[] readValues = resultRead.Values;

        for (int i = 0; i < instancePathList.Length; i++)
        {
            Console.WriteLine("Symbol: {0} (Value: {1}, Type: {2})", instancePathList[i], readValues[i].ToString(), valueTypes[i].Name);
        }

        // Sum Command Write
        SumHandleWriteAnyType writeCommand = new SumHandleWriteAnyType(client, handles, valueTypes);
        object[] writeValues = new object[] { true, (short)42, "MyNewProjectName" };

        await writeCommand.WriteAsync(writeValues,cancel);
        }

        SumReleaseHandles releaseCommand = new SumReleaseHandles(client, handles);
        await releaseCommand.ReleaseHandlesAsync(cancel);
    }
    }

    Console.WriteLine("");
    Console.WriteLine("Press [Enter] for leave:");
    Console.ReadLine();
}

See Also

Reference

TwinCAT.Ads.SumCommand Namespace ISumCommand SumCreateHandles SumHandleReadAnyType SumHandleWriteAnyType

Beckhoff Automation GmbH & Co. KG 2001-2026