ValueSymbolExtensions.PollValues<T>(IValueSymbol, TimeSpan, Boolean) Method

Polls the symbol as value sequence of object values with a specified period time (typed)


Namespace: TwinCAT.Ads.Reactive
Assembly: TwinCAT.Ads.Reactive (in TwinCAT.Ads.Reactive.dll) Version: 7.0.0+e56d35ccc4675faac24789a4aab60071fc61d470

Syntax

C#

public static IObservable<T> PollValues<T>(
this IValueSymbol symbol,
TimeSpan period,
bool ignoreErrors
)

Parameters

symbol  IValueSymbol

The symbol.

period  TimeSpan

The period.

ignoreErrors  Boolean

Ignore read errors (default values will be returned).

Type Parameters

T

Return Value

IObservable<T>
IObservable<System.Object>.

Usage Note

In Visual Basic and C#, you can call this method as an instance method on any object of type IValueSymbol. When you use instance method syntax to call this method, omit the first parameter. For more information, see Extension Methods (Visual Basic) or Extension Methods (C# Programming Guide).

Remarks

If ignoreErrors is not set and ReadRequest errors occur, the observable will be closed with error (AdsException)./> If errors are ignored, the observable will return NULL values on erroneous requests.